Ac Report 02-01-2023

You might also like

Download as pptx, pdf, or txt
Download as pptx, pdf, or txt
You are on page 1of 14

AC DEPARTMENT

WEEKLY
WORK REPORT
INDEX
1. DIP – 1
1.1 AL REYAMI PACKAGE UNIT MAINTENANCE
1.2 CFI LV ROOM A/C MAINTENANCE
1.3 ICE MAKER DISMANTLING
1.4 DIP 1 LABOUR CAMP COOLING TOWER 2
1.5 CDI – EVAPORATIVE CONDENSER MAINTENANCE
1.6 BED PROJECT – EVAPORATIVE CONDENSER MAINTENANCE
1.7 CDI - AMMONIA PLANT OIL DRAINING
1.8 CDI – AMMONIA PLANT GAS CHARGING
1.9 CHEMICAL DOSING
2. DUQM – DHOFAR FISHERIES
2.1 PIPING WORK
2.2 HEAD OFFICE AC INSTALLATION.
DIP - 1
CDI – AMMONIA PLANT
ELECTRICAL PANEL A/C

• The A/c unit was removed from the


location.
• The electrical wiring was checked,
and damaged wires were replaced.
• The contactor and thermostat were
changed.
• The pressure was checked on the
unit.
• The trial test was done, and the unit
was installed in the appropriate
location.
• The spare FCU and duct-able split
indoor units were taken out for
servicing.
• The condenser coil were treated
with caustic soda and water
servicing was done.
• The condenser coils were tested
for leaks.
• All the units were found to be in
good condition.
• Finally, the units were wrapped
up and stored.
BED PROJECT LV
ROOM A/C
MAINTENANCE
• The unit was shut down.
• The a/c unit was removed from the location.
• The air filters were cleaned .
• The motor condition was checked for
abnormal sound, vibration and heating.
• The refrigerant pressure was tested.
• The R22 gas was charged into the system due
to the low pressure.
• The trail run was conducted, and the unit
was fixed into the appropriate location and
started again.
CCI – AL REYAMI INK
STORAGE ROOM A/C
INSTALLATION
• The new split A/c unit was installed in the
ink storage room.
• The insulation was done on the pipeline.
• The electrical connection work needs to
be done for the unit.
HTC LV ROOM A/C
MAINTENANCE
• The unit was shut down.
• The a/c unit was removed from the location.
• The air filters, condenser and evaporator coils
were water serviced.
• The motor condition was checked for abnormal
sound, vibration and heating.
• The refrigerant pressure was tested.
• The R22 gas was charged into the system due to
the low pressure.
• The trail run was conducted, and the unit was
fixed into the appropriate location and started
again.
PASTALINI – CHILLED
WATER PIPE INSULATION
• The chilled water pipeline was insulated.
CDI AMMONIA PLANT 1
THERMOSIPHON
• The system was shutdown.
• All the valves were shut off. Further, the drain valve
was opened to drain the water from the
thermosiphon.
• The thermosiphon unit was inspected for leakages.
• No leakage was found.
• The drain valve (ball valve) was replaced due to
improper function.
TMP – COOLING TOWER
MAINTENANCE
• The system was shutdown.
• The water from the sump was drained.
• The drift eliminators were cleaned.
• The debris from the sump were cleaned.
• The strainer and sump filter were
cleaned and fixed again.
• The water was refilled again in the sump.
• The circulation pump was checked for
operational.
• The unit was started again for operation.
CDI – AMMONIA PLANT
GAS CHARGING AND
OIL DRAINING

• The refrigerant ammonia gas was


charged to the plant 1 system.
• The oil was drained from the unit to
check the oil condition.
1.11 CHEMICAL
DOSING

• The BAFRY chemical dosing is being done on a


daily.

• WXR EVAPORATIVE CONDENSER 1 – HFI


• WXR EVAPORATIVE CONDENSER 2 – HFI
• HEATAWAY EVAPORATIVE CONDENSER 1 - CDI
• HEATAWAY EVAPORATIVE CONDENSER 2 – CDI
• TEVA EVAPORATIVE CONDENSER- BED PROJECT
• COOLING TOWER - CFI
DUQM –
DHOFAR
FISHERIES