Quy trình chạy mẫu trên Cobas® 8100

Tổng quan

Company confidential; not for external distribution.


Cobas 8100 với 2 cobas 8000 và 1 p701

cobas 8100

Analyzers
Cobas p 701

3 Company confidential; not for external distribution.


Cobas 8100
Khối mở nắp
Tủ lưu trữ và
lưu mẫu tạm Khối nạp
mẫu

Máy ly tâm

Khối chiết
tách và
dán
barcode
Ramp

Khối xuất
mẫu
Khối đóng nắp
5 Company confidential; not for external distribution.
Quy trình chạy mẫu trên Cobas® 8100
Nắp cao su Xuất
Nắp mềm/ Add-on/ mẫu/ Khối nạp mẫu với Ly tâm tự động Mở nắp Dán barcode/ nạp Chiết mẫu
lưu mẫu Phân loại Stocker Holder ống phụ
Nắp vặn tạm mẫu

Output station Input station Aliquot station


Know where Boosting Continuing the
Compact, modular, 3-D intelligent samples are, Checking sample
productivity: tradition: quality
flexible: changes and bi-directional volume
at any time high throughput and reliability
grows with your needs transport system
cobas
Flexible Integrated
Connectivity laboratory
workflow post-analytics
information systems
STAT workflow:
Intelligent cobas
emergency Routine workflow Predictable
sample handling single tube Small footprint middleware
short TAT transportation solutions

7 Company confidential; not for external distribution.


Input Buffer Module (IPB)
• Sample loading using 4 drawers and 8, 50 position trays

• Module throughput 800 / 1100 s/h

• Loading area for up to 400 /800 samples

• Dedicated STAT port for single tubes

• Tube type identification

• Tube weight measured for centrifugation

8 Company confidential; not for external distribution.


Automatic Centrifuge Unit (ACU)
• 300 samples / hour for each centrifuge

• 3000g centrifugation force

• Stat Prioritisation

• Up to 3 modules per system

• Individual parameter setting per ACU

• SWA

• Coagulation

9 Company confidential; not for external distribution.


Destopper Module (DSP)
• 1,000 sample per hour

• Multi tube compatibility

• BD

• Starstedt

• Greiner

• Terumo

• Flex Cap

• Hitachi Cap

10 Company confidential; not for external distribution.


Sample Integrity Module
• 1,000 sample / hour

• Serum Indices

• Hemolitic, Icterus, Lipaemia

• Sample Volume Check

• Default Rules

• “Rule In, Rule Out”

11 Company confidential; not for external distribution.


Bar Code Labeller (BCL)
• Thermal transfer printer

• 3000 aliquot tubes onboard

• Automated consumable management

• Optional secondary tube type

12 Company confidential; not for external distribution.


Aliquot Module (AQM)
• Supplements primary tube workflow

• No on line analyser cups

• No on line aliquot disposal

• Send away samples


• High sensitivity assays e.g. serology
• Non water based aliquoting
• Pre loaded aliquot tips
• On the fly consumable loading
• 2D barcode printing on aliquot tube

13 Company confidential; not for external distribution.


Reformatter (RFM)
• Unloads from pucks to racks

• Allows sorting of “like” tubes

• 4 workflows to the analytics

• Dedicated stat workflow

• Pre set time out for rack


transport

• Connection to the tracking


lines

14 Company confidential; not for external distribution.


Restopper Module – Recap / Screw Cap
(RSP/RSF)
• 1,000 sample / hour

• On board capacity of 3000 caps

• Flex Caps
• primary and secondary 13 /16mm tubes

• Screw cap for Roche FBT


• batch analysis or send away

15 Company confidential; not for external distribution.


Sorter / Output Buffer (SOB)

• Primary tube sorting / distribution

• Aliquot tube sorting / distribution

• Send away sample sorting

• 400 tube capacity per module

• 1 or 2 module configuration

16 Company confidential; not for external distribution.


Add-on / Output Buffer (AOB)
• Add-on

• Re-run

• Repeat

• Reflex

• Holding buffer for sample request delay

• Loading area for up to 1-6000 samples

• Supports manual retrieval of samples

• Two buffering targets available per module

17 Company confidential; not for external distribution.