INHOUSE CALIBRATION OF REXROTH MAKE AMPLIFIER CARD

OF HAEUSLER BEND ROLL


Problem statement : Bottom roller rotation was stopped due to
Rexroth amplifier card malfunctioning
Background :
 Haeusler bottom roller amplifier card malfunctioning due to that
bottom roller rotation stopped.
 We had spare Rexroth amplifier card, but it couldn’t be used as it
was uncalibrated.
 We have contacted OEM regarding calibration issue but
according to OEM it was very complex procedure and couldn’t
calibrate remotely. Only it will be done by their expert which also
not possible due to pandemic situation.
 OEM approx. cost including lodging/boarding and service charge
was around 3 lacs, which would be affect production loss till their
expert came.

Solution :
 To resolve problem inhouse first we must find procedure to
Benefits : calibrate Rexroth amplifier card for haeusler machine.
 Skill enhancement of team  For that we brainstormed with our team and finalized
 Approx. 3 lac saving due to inhouse calibration calibration procedure.
 Reduce production loss  According to prepared procedure and with proper
precaution we have inhouse calibrated Rexroth amplifier
card