SERVICE DEVELOPMENT

PT FAJAR MAS MURNI

AIR FLOW SYSTEM


AIR FLOW SYSTEM
 ATMOSPHERIC AIR IS DRAWN IN FROM THE RIGHT END OF THE CABINET VIA INTERNAL SOUND
ATTENUATING DUCTING.

 WHEN THE INLET CONTROL BUTTERFLY VALVE IS OPEN THE AIR ENTERS THE 1st STAGE
AIREND WHERE IT IS COMPRESSED TO 26 TO 31 PSIG.
PT FAJAR MAS MURNI
SERVICE DEVELOPMENT


 THE AIR DISCHARGES THE AIREND VIA A VENTURI USED TO DISSIPATE PRESSURE PULSATION.

 FROM THE VENTURI THE AIR MOVES THROUGH A STAINLESS STEEL FLEXIBLE SECTION AND
ENTERS THE INTERCOOLER WHERE THE AIR IS COOLED TO 20° ABOVE AMBIENT
TEMPERATURE.

 THE AIR EXITS THE INTERCOOLER AND PROCEEDS THROUGH STAINLESS STEEL PIPING TO A
MOISTURE SEPARATOR ( WHICH INTERNALS ARE EPOXY COATED) WHERE CONDENSATE IS
REMOVED BEFORE PROCEEDING TO THE 2nd STAGE AIREND.

 THE AIR EXITS THE 2nd STAGE AIREND DIRECTLY INTO A SILENCER BOTTLE, AFTER WHICH IT
FLOWS INTO THE AFTERCOOLER.

 THE AIR TEMPERATURE IS LOWERED TO WITHIN 20°F OF THE AMBIENT AIR TEMPERATURE
BEFORE EXITING THROUGH A STAINLESS STEEL PIPE, INTO A CHECK VALVE AND THEN INTO A
MOISTURE SEPARATOR .

 ANY MOISTURE THAT HAS CONDENSED DUE TO THE LOWERING OF THE TEMPERATURE IS
REMOVED IN THE SEPARATOR AND THEN THE AIR FLOWS TO THE CUSTOMER SYSTEMS.
Air Filter
Blowdown Silencer

Inlet Valve Blowdown Valve

1AVPT
2ATT
SIERRA
AIR
1st Stage Expansion Joint Intercooler SYSTEM
1st Stage
Disc Venturi
1st Stage 3ATT
Airend Interstage
2APT Relief
Valve

Interstage
Moisture 7ATT
6SV Discharge
Separator Relief
4APT
1CS Valve
Interstage
Expansion 1MCV 1SSV Aftercooler
CCV
Joint
2nd Stage Package
Disc Venturi Moisture
Discharge Separator
2nd Stage Check 9SV
4ATT 3APT
Airend Valve
2nd Stage
Expansion 2CS

2SSV 2MCV
Air Filter
Blowdown Silencer

Inlet Valve Blowdown Valve

1AVPT
2ATT
SIERRA
AIR
1st Stage Expansion Joint Intercooler SYSTEM
1st Stage
Disc Venturi
1st Stage 3ATT
Airend Interstage
2APT Relief
Valve

Interstage
Moisture 7ATT
6SV Discharge
Separator Relief
4APT
1CS Valve
Interstage
Expansion 1MCV 1SSV Aftercooler
CCV
Joint
2nd Stage Package
Disc Venturi Moisture
Discharge Separator
2nd Stage 4ATT 3APT Check 9SV
Airend 2nd Stage
Valve
Expansion 2CS

2SSV 2MCV
AIR FILTER

 CLEANS AIR PRIOR TO INLET TO


PT FAJAR MAS MURNI
SERVICE DEVELOPMENT

AIREND
 99.5%EFF 10 MICRON
 OPTIONAL HIGH DUST 3 MICRON
RATING
SERVICE DEVELOPMENT

PT FAJAR MAS MURNI


INLET VALVE

 TO REGULATE AIR FLOW


PT FAJAR MAS MURNI
SERVICE DEVELOPMENT

 TEFLON IMPREGNATED SLEEVE


BEARINGS
 VALVE PLATE IS PRESS FIT TO
SHAFT
SERVICE DEVELOPMENT

PT FAJAR MAS MURNI


SERVICE DEVELOPMENT

PT FAJAR MAS MURNI


1st STAGE AIREND

 COMPRESSES AIR TO 26-40 PSIG


PT FAJAR MAS MURNI
SERVICE DEVELOPMENT
SERVICE DEVELOPMENT

PT FAJAR MAS MURNI


1st STAGE VENTURI

 PROVIDES PULSATION DAMPENING


PT FAJAR MAS MURNI
SERVICE DEVELOPMENT
SERVICE DEVELOPMENT

PT FAJAR MAS MURNI


FLEX LINE

 CORRUGATED STAINLESS STEEL


PT FAJAR MAS MURNI
SERVICE DEVELOPMENT

WITH
 EXTERIOR STAINLESS BRAID
 ALLOWS FOR EXPANSION AND
MISALIGNMENT
SERVICE DEVELOPMENT

PT FAJAR MAS MURNI


INTERCOOLER

 COOLS THE AIR PRIOR TO THE INLET


PT FAJAR MAS MURNI
SERVICE DEVELOPMENT

OF THE 2nd STAGE AIREND.


 NORMAL TEMP IS 20°F ABOVE
AMBIENT ON AIR-COOLED AND 15°F
ABOVE INLET WATER TEMP. ON
WATER COOLED
 ST. STEEL PIPE TO MOISTURE
SEPARATOR
SERVICE DEVELOPMENT

PT FAJAR MAS MURNI


INTERSTAGE MOISTURE
SEPARATOR
 COLLECTS ANY MOISTURE PRIOR
PT FAJAR MAS MURNI
SERVICE DEVELOPMENT

TO 2nd STAGE
 CYCLONE TYPE
 EPOXY COATED INTERIOR
SERVICE DEVELOPMENT

PT FAJAR MAS MURNI


2nd STAGE AIREND

 COMPRESSES AIR FROM 26-40 PSIG


PT FAJAR MAS MURNI
SERVICE DEVELOPMENT

TO DISCHARGE PRESSURE
SERVICE DEVELOPMENT

PT FAJAR MAS MURNI


2nd STAGE SILENCER

 PROVIDES PULSATION DAMPENING


PT FAJAR MAS MURNI
SERVICE DEVELOPMENT

AND SILENCING
 PULSATION BOTTLE OR VENTURI
SERVICE DEVELOPMENT

PT FAJAR MAS MURNI


SERVICE DEVELOPMENT

PT FAJAR MAS MURNI


AFTERCOOLER
 COOLS THE DISCHARGE AIR FROM THE
PT FAJAR MAS MURNI
SERVICE DEVELOPMENT

2nd STAGE AIREND PRIOR TO EXITING


THE PACKAGE
 NORMAL TEMP IS 20°F ABOVE AMBIENT
ON AIR-COOLED AND 15°F ABOVE INLET
WATER TEMP. ON WATER COOLED
 STAINLESS STEEL PIPE TO MOISTURE
SEPARATOR
SERVICE DEVELOPMENT

PT FAJAR MAS MURNI


SERVICE DEVELOPMENT

PT FAJAR MAS MURNI


CHECK VALVE

 ISOLATES CUSTOMERS SYSTEM


PT FAJAR MAS MURNI
SERVICE DEVELOPMENT

FROM COMPRESSOR
 DUAL FLAPPER BUTTERFLY TYPE
 STAINLESS STEEL
SERVICE DEVELOPMENT

PT FAJAR MAS MURNI


MOISTURE SEPARATOR

 TO REMOVE CONDENSED WATER


PT FAJAR MAS MURNI
SERVICE DEVELOPMENT

FROM AIR STREAM PRIOR TO


DISCHARGING INTO CUSTOMER
PLANT
 CYCLONE TYPE
SERVICE DEVELOPMENT

PT FAJAR MAS MURNI


SERVICE DEVELOPMENT

PT FAJAR MAS MURNI


CONDENSATE DRAINS
 DRAINS COLLECTED CONDENSATE
 1 FOR INTERCOOLER MOISTURE
PT FAJAR MAS MURNI
SERVICE DEVELOPMENT

SEPARATOR
 1 FOR AFTERCOOLER MOISTURE
SEPARATOR
 AUTOMATIC SOLENOID TYPE
 Y TYPE STRAINER PRIOR TO VALVE.
 STAINLESS PIPING PREVENT RUST
FROM CLOGGING VALVE
SERVICE DEVELOPMENT

PT FAJAR MAS MURNI


CONDENSATE DRAINS
 OPEN 5 SECONDS AT ADJUSTABLE
PT FAJAR MAS MURNI
SERVICE DEVELOPMENT

INTERVALS
 90 SECONDS TO 270. DEFAULTS TO 120
SEC.
 OPENS 5 SECONDS ON UNLOAD AND LOAD
 ANYTIME UNIT IS POWERED UP BUT NOT
RUNNING FOR ANY REASON, THE
CONDENSATE SOLENOIDS OPEN 5
SECONDS EVERY 600 SECONDS
AIR INSTRUMENTATION
 1AVPT INLET VACUUM
PT FAJAR MAS MURNI
SERVICE DEVELOPMENT

 2APT 2nd STAGE INLET PRESSURE


 3APT 2nd STAGE DISCHARGE PRESSURE
 4APT PACKAGE DISCHARGE PRESSURE
 2ATT 1st STAGE DISCHARGE TEMPERATURE
 3ATT 2nd STAGE INLET TEMPERATURE
 4ATT 2nd STAGE DISCHARGE TEMPERATURE
 7ATT PACKAGE DISCHARGE TEMPERATURE
 I/C CONDENSATE LEVEL SWITCH (optional)
 WATER FLOW DELTA P SWITCH (Water-cooled)
SERVICE DEVELOPMENT

PT FAJAR MAS MURNI