Professional Documents
Culture Documents
GROUND SUPPORT EQUIPMENT (Rev 2.0)
GROUND SUPPORT EQUIPMENT (Rev 2.0)
SERVICES
MEET OUR TEAM
Introduction
Summary
Refuelers
Non-potable water trucks
Lavatory
Ground power units (GPU)
Buses
Belt loaders
Ambulift
Transporters
De/anti-icing vehicles
Passenger boarding steps/sta
Catering vehicle irs
2 Use JCPL for transfer loads from /to the platform aircraft
Usually, pressure refueling is used when it comes to the refueling of large aircraft
such as Boeing 747 and gravity fueling is used on small aircraft such as Cessna 172.
This article will describe process of pressure refueling and there are several steps and
precautions that must be done by responsible personnel.
DO NOT REFUEL IF
•the aircraft Engines are running.
•if you notice electrical storming.
•if oxygen servicing is being perform in the aircraft.
•if any part of the aircraft is over hot.
Position fuel truck Connect fuel hose Fueling Disconnect fuel hose Clear area
There are several connect the fueling Stop fueling once the Remove the fueling Finally, ensure the fuel
steps of aircraft nozzle grounding desired fuel quantity nozzle grounding does not come in
refueling and it starts cable to the aircraft has been reached. cable from the aircraft contact with skin,
with the grounding of grounding receptacle This can be monitor grounding receptacle, clothes and eyes.
aircraft and the fuel and immediately from the cockpit the fuel tanker from Immediately clean and
tanker. Do not drag remove the filler cap. gauge reading. the aircraft and wash with water and
the hose along the After that, insert the Is not more than grounding cable from special soap if this
leading edge. fuel nozzle into filler 250ib (113.40g) the aircraft as well as happens and also seek
cap and commence from the tanker. for the medical
Once fueling process
fueling which is attention. If there is
is done, install and
carried out by the secure the filler cap. any spillage of fuel on
suction method which the ground, clean the
is provided by the spillage
tanker.
Modem lavatories are now no longer of the "chemical toilet blue water re-
circulated electric flush" variety. Instead lavatory manufacturers have progressed
to "vacuum flush" technology to eliminate solid and liquid residue from the
basin, patented in 1975.
Position lavatory truck Connect hose Vacuum lavatory Disconnect hose Clear area
…. … .. .. ..
Safety
Follow SOP procedure to
reduce damage and
accidents
Costing
Time and money
www.ameacademy.com