Iot Based Air and Sound Quality Monitoring Up

You might also like

Download as pptx, pdf, or txt
Download as pptx, pdf, or txt
You are on page 1of 15

Welcome to Our

Presentation
IOT BASED AIR AND SOUND
POLLUTION MONITORING SYSTEM.
Presented by

Md. Tariqul Islam Supervisor


ID: 1912003005 Md. Mehbub - A - Kabir
Lecturer
Md. Masud Sikder
Department of Electrical and Electronic Engineering
ID: 1912003072 City University , Bangladesh
Md. Riajul Islam
ID: 1912003529

DEPARTMENT OF ELECTRICAL AND ELECTRONIC ENGINEERING

CITY UNIVERSITY , BANGLADESH


CONTENTS
• INTRODUCTION
• OBJECTIVE
• EQUIPMENT
• BLOCK DIAGRAM
• WORKING EXPLANATION
• CIRCUIT DIAGRAM
• RESULT
• PROJECT OUTLOOK
• ADVANTAGES
• LIMITATIONS
• FUTURE WORK
• CONCLUSION
INTRODUCTION
Continued exposure to environments with poor air quality is a major public health concern in
developed and developing countries. It is estimated that the pollutants responsible for poor air
quality cause nearly 2.5 million premature deaths per year world-wide. Significantly, around
1.5 million of these deaths are due to polluted indoor air, and it is suggested that poor indoor
air quality may pose a significant health risk to more than half of the world’s population. Due
to its link with industrialization, societal health problems associated with poor air quality
disproportionately affects developed and developing nations – it is estimated that air pollution
is responsible for the premature deaths. Remedial action to improve air quality is often easy to
implement once airborne pollutants have been detected.
OBJECTIVE
• The intention of this project is to measuring the harmful gases present in the air and also
sound pollution.

• These data's are pushed in to online server over internet.

• The main idea is to reduce the cost and control the pollution.
3
Equipment

MQ-4 SENSOR MQ-7 SENSOR

MQ-135 SENSOR

SOUND SENSOR(KY-038)
ESP-32

LCD DISPLAY

BUZZER
POWER SUPPLY
BLOCK DIAGRAM

Internet
MQ- 7 Server

MQ- 4
NODE MCU

MQ- 135
Start Flow Chart
Connecting to
NO Internet
Yes
Taking Input From Show Data to
Sensors Display

Show Data to
Process Data
Internet Server

If sensor Yes
data > set Open Alarm End
NO value
Circuit Diagram
RESULTS IN MORNING TIME:

SENSORS MEASURED EXPECTED


VALUE VALUE
CH4 (ppm) 1740 1800
Co2 (ppm) 430 450
CO (ppm) 90 85
Sound (decibels) 113 120

RESULTS IN EVENING TIME:

SENSORS MEASURED EXPECTED


VALUE VALUE
CH4 (ppm) 1750 1800
Co2 (ppm) 490 450 1
CO (ppm) 89 80
Sound (decibels) 118 120
Project Outlook

1
ADVANTAGES
• Low cost and low power consumption.
• It is eco friendly.
• Highly accurate for monitoring system purpose.
• Very high range and multi-mode connectivity.
LIMITATIONS

• Concerned authority only getting information.

• Polluted areas location is not available.

• There is no preventive action had taken.

• Very low range of connectivity.


FUTURE WORK
• Certain relationship between the air pollutants can be found.
• Sensors can be more calibrated against a range of temperature and humidity.
• Self – Calibration techniques can be implemented in future.
• Controlling Port
CONCLUSION
• Thus the real time air and noise pollution levels are monitored and some controlling actions
are taken through IoT.

• Our proposed system provides low cost, highly accurate and long range of connectivity.

• This will definitely create a great impact to our society and environment.

• For balanced and to leasable environment this project is mostly related and necessary for us.

You might also like