Download as pptx, pdf, or txt
Download as pptx, pdf, or txt
You are on page 1of 12

Aknel AG Rust Stop 2W

Friday, May 5, 2023


Data
Product Tested: Aknel AG Rust Stop2W
Painting Date:

Validation Criteria – TSP00572/4


• HESA – ok for testing

Quality Sucker Rods - Romania Tenaris Friday, May 5, 2023 2


Tests – Flow time

Viscosity - Ford Cup No. 4


> 17 sec

T [°C] Flow time [s]


20.6 59.39
20.6 57.94
20.6 57.74

Quality Sucker Rods - Romania Tenaris Friday, May 5, 2023 3


Tests – Film thickness

Value [µm]
Sample No
1 2 3 Avg [µm]
1 58 48 53 53
2 45 53 53 50
3 44 46 48 46
4 46 46 47 46
5 45 57 52 51
6 46 40 44 43

The film thickness has


been measured after the
paint got dry
Samples surface
after painting

Quality Sucker Rods - Romania Tenaris Friday, May 5, 2023 4


Tests – Oil solubility
The test has been made by immersion of the painted sample in a recipient with diesel.
After immersing for 72 h, paint on the rod sample did not become fluid.
Pic 1

Pic 2

Quality Sucker Rods - Romania Tenaris Friday, May 5, 2023 5


Tests – Scab test

The Scab test has been performed with a solution of Sodium Chloride and water, according
ISO 11474 (30 gr/L).

The spraying started on 17th of Jan 2021

21st of Jan 25th of Jan 2nd of Feb

Quality Sucker Rods - Romania Tenaris Friday, May 5, 2023 6


Tests – Scab test
4th of Feb 8th of Feb 11th of Feb
Details Details Details

Quality Sucker Rods - Romania Tenaris Friday, May 5, 2023 7


Tests – Scab test
4th of Feb – Details of the appeared rust after 18 days from spraying with saline solution
• The rust is located on the samples base, at the contact with the plastic support

Quality Sucker Rods - Romania Tenaris Friday, May 5, 2023 8


Tests – Scab test
8th of Feb – Details of the rust after 22 days from spraying with saline solution
• The rust is located on the samples base, at the contact with the plastic support

Quality Sucker Rods - Romania Tenaris Friday, May 5, 2023 9


Tests – Scab test
11th of Feb – Details of the appeared rust after 25 days from spraying with saline solution
• The rust is located on the samples base, at the contact with the plastic support

Quality Sucker Rods - Romania Tenaris Friday, May 5, 2023 10


Tests – Heat test

The sample 1 was


heated more than
100 deg C for 10
minutes and showed
good behavior – no
leaking

Quality Sucker Rods - Romania Tenaris Friday, May 5, 2023 11


Tests – Heat test

Quality Sucker Rods - Romania Tenaris Friday, May 5, 2023 12