Professional Documents
Culture Documents
03 Topology Ok
03 Topology Ok
Motion Academy
Corporate Technology
Topology
CU320-2 ALM MM MM
X103
X202 X202 X202
X102
TM15 X101
X201 X201 X201
DRIVE-CLiQ cables
DRIVE-CLiQ cables
Motion Connect
Gray: 2 x 2 x 0.22
Green: with 24 V
2 x 2 x 0.22 + 1 x 2 x 0.38
Line topology
Tree topology
No dual MM MM No ring
wiring Basic clock Basic clock wiring
CU320-2 cycle cycle
X103
TM15 125 µs 125 µs
X102 X202 X202
X501
X201 X201
X500 X101
X200 X200
X100
SMC
ALM
Basic clock
cycle
250 µs X500
X202
VSM SMI
X201
X200
When wiring components with DRIVE CLiQ, the following rules apply among others:
• No ring wiring, no double wiring
• The maximum number of nodes on one DRIVE-CLiQ line is 14
• The maximum Motor Modules on one DRIVE-CLiQ line is 8
• The maximum number of Terminal Modules is 16
CU320 ALM MM MM
X103
X202 X202 X202
X102
TM15 X101
X201 X201 X201
X500
VSM SMI
Signals from more than one encoder can be collected by the DMC20 DRIVE-CLiQ Hub
and forwarded to the Control Unit on a single DRIVE-CLiQ cable.
X500 Sensor
X100 Module
X101
X500 X501
X102
X502 X500 Sensor
X103
Module
X503
DRIVE-
X504
CLiQ Hub
CU320-2 DMC20 X500 Sensor
X505
Module
X100
Single
Motor
Single
Motor
... Single
Motor
X500 X501
X101
Module Module Module
X502
X102
X202 X202 X202
X503
X103 DRIVE-
X504
CLiQ Hub
DMC20 X505 ...
CU320-2
CU320 ALM MM MM
X103
X202 X202 X202
X102
TM15 X201 X201 X201
X101
X200 X200 X200
X501 X100
X500 SMC
M M
Line
~ ~ X500
VSM
SMI
figuration Load to PG
Serial no. A Serial no. A OPERATION Serial no. A
Module exchange
Load to PG
Serial no. B OPERATION Serial no. B
DQI
DQ DQI
(SMI)
DRIVE-CLiQ-Geber
Disassembly Installation
• Disconnect the motor • Attach the new coupling element onto
• Remove the four encoder fixing screws the encoder shaft
• Remove the old encoder and coupling element • Align the coupling element with the
coupling half on the motor
• Attach the new encoder at this position on
the motor shaft
• Mount the new encoder using the
4 screws (tightening torque: 2.5 - 3 Nm)