Download as pptx, pdf, or txt
Download as pptx, pdf, or txt
You are on page 1of 8

SVERKER 900 updated to version 2.

14
SVERKER Viewer updated to version 2.14

May 2020
Multiple timing test in prefault-fault instrument
MTT in PF-F instrument
 MTT in PF-F instrument
• Test the characteristic of a current ,voltage or frequency relay
• Select reference curve with Definite time or IDMT, Inverse
Definite Minimum Time
• In normal mode three thresholds can be set
• The lowest threshold reference curve can be selected as IDMT
or Definite curve and the two other thresholds can be selected
only as Definite curve
Graph view Settings view Graph with reference curve Result table with reference time
Multiple timing test in prefault-fault instrument

 Advance mode
• Possible to set four thresholds
• Select reference curve with Definite time or IDMT independent of threshold
Multiple timing test in prefault-fault instrument

 Advance mode
• The Minimum time setting is to limit an IDMT curve to a certain minimum time
Multiple timing test in prefault-fault instrument

 Multiple timing test (in the prefault-fault


instrument) is available for Standard and
Expert versions.
 In addition, to use reference curves the
Viewer license is also required.
 Note that the Viewer license is hardware
based and unlocks a unit to generate files
that Viewer can read. The Viewer program
itself can be installed on any computer.
MCB mode

 Time testing of low voltage


breaker MCB and MCCB
• Setting of Extra Timer to
MCB mode
• Internal START and STOP
• BI – Binary Input 1 to 4
will be disabled
Improved reporting

 SVERKER Viewer is updated to display


graphs with reference curves
 The graphs used in the test equipment
are automatically displayed in the report.
An additional table shows all results.
 Compatibitlity
• This version of Viewer opens files
from SVERKER 900 version 2.10
and later.
• Files generated by SVERKER 900
version 2.14 needs this new version
of Viewer.
• We recommend to always keep
hardware and PC software updated
to have the latest functionality.
List of additional features and improvements

 Increased resolution on Ammeter with totally four decimal


in range 0 A to 1 A
 Improved functionality of the knob, to make testing even
easier
 Improved functionality on the virtual keyboard
 Reduced time when starting instruments
 Reduced time when going in-between Instrument
 Support for additional languages - Chinese
 Several additional fixes and improvements