TECHNICAL TRAINING

IC ENGINE CONTROLS AND


FUEL SYSTEMS
Title

© MITSUBISHI LOGISNEXT AMERICAS INC. All Rights Reserved.


Title

• Simple Layout
-7 total pages
-ECM,VCM,DCM,OCM, FC/MC

• Diagram ID lower right corner


- Models and Serial numbers

• VCM I/O and signals


-CN1/CN2

• Pins 600/601 12v to VCM


• Pins 975/976 0v/NEG to VCM

© MITSUBISHI LOGISNEXT AMERICAS INC. All Rights Reserved.


Title

© MITSUBISHI LOGISNEXT AMERICAS INC. All Rights Reserved.


Title

MC– Manual control hydraulics FC– Fingertip Control Hydraulics

Always check to make sure you are looking at the correct model schematic for your truck

© MITSUBISHI LOGISNEXT AMERICAS INC. All Rights Reserved.


Title

VCM - Each connector is I/O

Key points:
• 610 – PDS
© MITSUBISHI LOGISNEXT AMERICAS INC. All Rights Reserved.
Title

CAN BUS
-CN2 715/716 Optional
Sensors
© MITSUBISHI LOGISNEXT AMERICAS INC. All Rights Reserved.
Title

Highlight ALL fuses that have power with battery connected and key OFF

Using a different color, highlight ALL fuses that power up with battery connected, and key ON

© MITSUBISHI LOGISNEXT AMERICAS INC. All Rights Reserved.


Title

 Starter relay- 12v input to coil from pin 122 of Key Switch, NEG input from FNR lever and
Neutral SW
Supplies 12v to starter coil at S

 IGN Relay – 12v input to coil from pin 121 of Key Switch , NEG input from chassis ground,
When coil closes the relay will power VCM Fuse, Meter Panel Fuse, Back up lamp fuse, Fuel
Disconnect fuse
© MITSUBISHI LOGISNEXT AMERICAS INC. All Rights Reserved.
Title

 EGI(1) – Shares a NEG and 12v with EGI (2), 12v comes from F7, supplies 12v to Spark Plugs

 EGI (2) – Supplies 12v to MAIN/C Relay coil , Supplies 12v to OCM, Supplies 12v to Main INJ, Sensors,
Crankshaft and Camshaft, INJ assistance, Air Flow Sensor. 12v supply to activate ECM @ pins 189/190

 MAIN/C – Supplies 12v to Fuel Lock solenoid and LPG/GAS selector switch

 ETC Motor- 12v from F9, 12v to ECM @ pin 192. The ECM knows the relay is functional when it sees
voltage at pin 192, if no voltage is seen a E31 code will generate

© MITSUBISHI LOGISNEXT AMERICAS INC. All Rights Reserved.


Title

© MITSUBISHI LOGISNEXT AMERICAS INC. All Rights Reserved.


Title

© MITSUBISHI LOGISNEXT AMERICAS INC. All Rights Reserved.