Aanandaban Laboratory Building

Summary for Frame System Approach


Original Model with Shear
Walls
Proposed Model with Frame
System
Beam Plan (L2 &
L3)
Beam Plan
(LR)
Column Elevation
(1-1)
Column Elevation
(2-2)
Column Elevation
(3-3)
Column Elevation
(4-4)
Column Elevation
(4-4)
Required Reinforcement
(mm2)
Reinforcement
Percentage
Reinforcement
Percentage
Story Drift
Story Drift
Ultimate Limit State
Storey Drift Limiting value not exceeding : 0.025
Ductility Story Design Storey Design
Floor Loading Direction Condition Loading Direction Condition
Factor Drift Storey Drift Drift Storey Drift
LR 4 EQx X 0.003467 0.013868 OK EQy Y 0.0033 0.013136 OK
L3 4 EQx X 0.002564 0.010256 OK EQy Y 0.0029 0.011792 OK
L2 4 EQx X 0.000742 0.002968 OK EQy Y 0.0003 0.001116 OK
L1 4 EQx X 0 0 OK EQy Y 0 0 OK

Serviceability Limit State


Storey Drift Limiting value not exceeding : 0.006

Floor Loading Direction Storey Drift Condition Loading Direction Storey Drift Condition
LR EQx X 0.00333 OK EQy Y 0.003153 OK
L3 EQx X 0.002462 OK EQy Y 0.002831 OK
L2 EQx X 0.000712 OK EQy Y 0.000268 OK
L1 EQx X 0 OK EQy Y 0 OK
Change in Concrete
Volume
Concrete Volume (m3)
Frame System Shear Wall System
354.238 405.985

15% reduction in concrete volume when going from shear wall system to
frame system.
Soil Retaining Option 1
Soil Retaining Option 2