Boiler Walk Down Checks PMI

You might also like

Download as ppt, pdf, or txt
Download as ppt, pdf, or txt
You are on page 1of 12

Routine Checks

Boiler

July 23, 2023 PMI Revision 00 1


Main Boiler
 BOTTOM ASH HOPPER
SEAL TROUGH & HOPPER CONDITION
 FIRING FLOOR

 FIRING ARRANGEMENT

 BURNER TILT MECHANISM

 SECONDARY AIR DAMPERS

 FLAME CONDITION

 PEEP HOLE/MANHOLES

 PF LEAKAGE

 MULSIFIER SYSTEM
July 23, 2023 PMI Revision 00 2
 BOILER TUBE LEAKAGE (INTERNAL OR EXTERNAL)

 BOILER SUPPORTS

 BOILER EXPANSIONS

 SAFTY VALVE PASSING

 WATER WALL SOOT BLOWERS & LRSB ‘S

 ECONOMISER HOPPERS

July 23, 2023 PMI Revision 00 3


Boiler Auxiliaries
AIR PRE HEATERS
 DRIVES
 ANY ABNORMAL SOUND
 OIL LEVEL
 AIR MOTOR STAUS
 SOOT BLOWERS

 GUIDE & SUPPORT BEARINGS


 OIL SUMP LEVEL
 OIL COOLING SYSTEM
 HOT AIR LEAKAGE
 OIL FLOW & PRESSURE

 INFRA. RED DETECTION SYSTEM

July 23, 2023 PMI Revision 00 4


Boiler Auxiliaries
INDUCED DRAFT FAN
 LUBE OIL SYSTEM
 OIL LEVEL
 OIL PRESSURE, ADJUST IF REQD.
 FILTER CHOKING & OIL COOLERS
 ANY ABNORMALITY IN RUNNING PUMPS
 HYDRAULIC COUPLING
 WORKING OIL LEVEL
 W.O. PRESSURE
 FILTER CHOKING & OIL COOLER STATUS
 BEARING / OIL COOLER TEMP.
 ANY ABNORMAL SOUND

July 23, 2023 PMI Revision 00 5


Boiler Auxiliaries
FORCED DRAUGHT FAN

 LUBE OIL SYSTEM


 OIL PRESSURE & FLOW
 OIL COOLERS & FILTERS
 CONTROL OIL PRESSURE (Blade Pitch Control)
 ANY ABNORMALITY

July 23, 2023 PMI Revision 00 6


Boiler Auxiliaries
PRIMARY AIR FAN
 LUBE OIL SYSTEM
 OIL LEVEL & PRESSURE
 FILTER CHOKING & OIL COOLERS
 ANY ABNORMALITY IN RUNNING OIL PUMPS
 HYDRAULIC COUPLING
 WORKING OIL LEVEL
 W.O. PRESSURE
 FILTER CHOKING & OIL COOLER STATUS
 BEARING / OIL COOLER TEMP.
 ANY ABNORMAL SOUND IN FAN/MOTOR

July 23, 2023 PMI Revision 00 7


Boiler Auxiliaries

MILLING SYSTEM
 LUBE OIL SYSTEM – PUMP ,FILTERS, OIL LEVEL
 OIL COOLING SYSTEM
 MILL ROLLER SYSTEM
 MILL REJECTION STATUS
 ANY INTERNAL ABNORMAL SOUND
 ANY P.F. LEAKAGE
 MILL FIRE FIGHTING SYSTEM

July 23, 2023 PMI Revision 00 8


Boiler Auxiliaries
GRAVIMETRIC FEEDER
COAL FEEDING THRU’ VIEW GLASS
CLEAN OUT CONVEYOR
INTERNAL LIGHT
ANY ABNORMAL SOUND

SCANNER AIR FAN


SUCTION & DISCHARGE DAMPERS
PHYSICAL ABNORMALITY
EMERGENCY DAMPER STATUS

SEAL AIR FAN


SUCTION & DISCHARGE DAMPERS
ABNORMAL SOUND
DISCHARGE HDR. PRESSURE.

July 23, 2023 PMI Revision 00 9


Boiler Auxiliaries
BOILER CHEMICAL DOZING
 PREPARATION & STORAGE CHEMICAL TANK LEVELS
 PUMPS
 ANY CHEMICAL LEAKAGE
 LINE FLUSHING

BOILER BLOW DOWN


BLOW DOWN TANKS
BLOW DOWN LINES (CBD , IBD, EBD )

July 23, 2023 PMI Revision 00 10


Boiler Auxiliaries
ELECTROSTATIC PRECIPITATOR
 FIELD CHARGING

 FIELD CURRENT, VOLTAGE & SPARK RATE

 COLLECTOR & EMMITTER RAPPING MECH.(INT. & CONT. MODE)

 RECTIFORMER HEALTHINESS

 HOPPER EMPTYING STATUS

 DE ASHING STATUS

July 23, 2023 PMI Revision 00 11


THANK YOU

July 23, 2023 PMI Revision 00 12