Download as pptx, pdf, or txt
Download as pptx, pdf, or txt
You are on page 1of 7

Daily Pick Up Error Countermeasure Study Report

Date Shift Line Model M/C Table Feeder Part No Type Count Error PPM %

02-08-23 1st 18 Excalibur he top 3 5 9L 242280000902 Led 7260 12 1653 0.16

Root Cause PIC

Pick & recog error , line already convert to other model.Next run will check
Daily Pick Up Error Countermeasure Study Report
Action Before After
Monitoring last run before convert model

Result
Count 5831
Error 7
Percentage 0.12%

Trend Graphic
Daily Pick Up Error Countermeasure Study Report

Date Shift Line Model M/C Table Feeder Part No Type Count Error PPM %

EXCALIBUR HE
02-08-23 2nd 18
BOT
1 1 9R 932232299685 Led 5329 81 15200 1.51

Root Cause PIC

Suddendly High After Splicing Comp At Break Time, Cause By Sticky Part From PURNAMA
Incoming
Daily Pick Up Error Countermeasure Study Report
Action Before After
Change The Other Part And Make Indication For
Defect Part, start replace and monitoring
13.15 ~ 16.00 pm

Image Image
Result : OK
Count 1936
Error 0
Percentage 0%

Trend Graphic
Daily Pick Up Error Countermeasure Study Report

Date Shift Line Model M/C Table Feeder Part No Type Count Error PPM %

02-08-23 3rd 18

Root Cause PIC


Daily Pick Up Error Countermeasure Study Report
Action Before After

Image Image
Result
Count
Error
Percentage %

Trend Graphic
Daily Pick Up Error Countermeasure Study Report

Top 1 Causal Factor Analysis

Shift M/C Table Feeder Part No Count Error PPM % Causal Factor
1st 3 5 9L 242280000902 7260 12 1653 0.16
2nd %

3rd %

Causal Factor

Unstable Pick Up Index Image Recognition Error Pickup Pressure