1206 - 29 - 1359363045 - Spazio Forma Presentation

You might also like

Download as ppt, pdf, or txt
Download as ppt, pdf, or txt
You are on page 1of 10

Spazio Forma

1
Company Confidential
Spazio Forma
Technical Characteristic

2
Company Confidential
Spazio Forma
Principles of operation – main components

On the control board there are 2 Fuses,


-7 A – 220 V Ac – protect the UP/DOWN
movement
-1 A – 220 V AC – protect all the board

3
Company Confidential
Spazio Forma
Control board power distribution

4
Company Confidential
Led in the display board

Led in the control board

5
Company Confidential
Spazio Forma
Tread-belt motor drive

L6 (led 6) on the control board is ON when MSW is 3.5 Vdc.

L3 (led 3) on the control board os flashing if RPM is 3.7


Vdc; if the speed sensor is working.

6
Company Confidential
Speed error in the display

Does the error appear


· Consideration: the error appear · The reason of the problem is
immediately when the machine
only when you start the exercice. the signal MHW
is switched on?

Measure the signal MHW


Replace the
between pin 1-13 on the driver
Press quick start. driver board
board. Is it 12 VOLT?
Does the main motor move for some
seconds?

Replace the
cable that Measure the signal MHW
· It means that the 2 signals that A connect CPU between pin 1-13 on the CPU board.
enables the movement are OK so and driver Is it 12 VOLT?
the problem is related to the board
speed signal.

Adjust the position of the speed


Is the LED 3 of the speed flashing sensor board closer to the magnets, if
on the control board? the problem is still present replace it Replace the
and the cable CPU

Is the RPM going out from


Replace the control board
the control board

Replace the cable that connect


Is the RPM signal arriving to the CPU
CPU and driver board

A
Replace the CPU

Switch OFF- switch ON the machine and press quick start and verify the presence of the signals that
enable the movement::
- at the output of the CPU
- at the input of the driver board
- at the output of the driver board
The problem can be:
- the CPU (if the signals are not present at its output)
- The driver board (if the signals are present at its input but not present at its output)
- The cable that connect the CPU with the driver board (if the signals are present at the output of the CPU
but not present at the input of the driver board)
- The CHOKE or the cable that connect then driver board with the motor (if the signal is present at the
output of the driver board but not at the brushes of the motor)
7 - The brushes of the motor or the motor itself (if the signal is present at the brushes of the motor)

Company Confidential
Spazio Forma
Elevation motor drive

L5 (led 5) on the control board is ON when IN UP is 5.0Vdc.

L4 (led 4) on the control board is ON when IN DN is 5.0Vdc.

On the control board there are 2 Fuses,


-7 A – 220 V Ac
-1 A – 220 V Ac

8 Both are protecting the UP/DOWN circuit


Company Confidential
Spazio Forma
Summary of the signals

9
Company Confidential
Spazio Forma
signals summary in the patch connector

Display Board

IN
MSW PWM DOWN IN UP

FOLD
SAFE MHW Over +12 +12
OUT ADIN RPM GND GND
clock Vdc Vdc

Control Board

10
Company Confidential