BUILDING MANAGEMENT SYSTEM

BUILDING MANAGEMENT SYSTEMS PRIMARILY BENEFITS


THE FOLLOWING.

• Automises all manual control systems.


•Saves Energy & Operational Cost.
•All Multi Applications Systems operations through a single window.
• Provides Security & Safety for Data.
• Keeps History of Data and facilitate trouble shooting.
• Reduces Manpower, Human errors & Maintenance.
• And Many More like time scheduling, reports, logging data, event viewer etc.
SYSTEM HIERARCHY

 MANAGEMENT
LEVEL(LEVEL#3)

BACnet / Ethernet IP

Network Interface Card  MANAGEMENT


LEVEL(LEVEL#3)
BACnet / LonTalk

Stand alone Automation  AUTOMATION


Controllers LEVEL(LEVEL#2)

Field peripherals  FIELD


LEVEL(LEVEL#1)
FIELD LEVEL: LEVEL # 1
Level-1 Comprises of Input-Output field devices with
following type of I/O points:
 Inputs
The universal inputs (UI) accept passive and active sensor elements as well as volt-free
contacts (binary inputs) for signal functions.
 Passive sensors - Ni1000 , Pt100, Pt1000 (designed for temperature sensing-AI)
 Active - 0 ... 10 V DC / 4…20mA / 0….20mA (Analog input e.g. rpm, modulating, temp.
voltage, water flow, current, frequency etc.)
 Binary Volt-free /DC 24 V (DI e.g. on/off, fault/no-fault, open/close, hi/lo level etc.)
 The purely binary inputs (DI) enable signal and counter functions.
 Binary Volt-free (DC 24 V)
 Counter Pulses Volt-free up to 20 Hz (DC 24 V)
 Outputs
 Universal outputs can control modulating actuators as analogue output (AO) and also
can be programmed via the program structure for binary switching functions as digital
outputs (DO).
 Analogue output (AO) 0 ... 10 VDC / 4..20mA / 0…20mA
 Binary 0 or DC24 V, max. 22 mA
 The relay outputs (DO) are designed for max. AC 250 V, 2 A.
FIELD DEVICES:
Sensors and switching devices
Temperature sensors
Pressure sensors
Voltage Transducers
Water flow switches
Air velocity sensors
CO2 / O2 sensors
Differential Pressure switches
Flow meters
Water level transmitters/Switches
Oil level transmitters/Switches
Variable Frequency Drives
Damper Actuators etc.
FIELD DEVICES:
Valves and Actuators

Valves for HVAC main plant control


Valves for modulating actuators for AHUs
Butterfly valves and actuators
AUTOMATION LEVEL : LEVEL # 2

Level-2 Automation covers the DDC(Direct Digital


Controller),which have following features:

Salient features:-
 32 bit microprocessor
 Standalone controller
 UL Listed
 24MB to 80MB RAM
RANGE of DDC : There are mainly two series of DDC
controller depending upon the I/O arrangement one is fixed
controller & another expandable one. They are known as
Compact Series (Fixed type) & Modular Series (expandable
COMPACT
type) SERIES(Fixed Type) : By the name, it suggests
that this series can not extended beyond the assigned I/O
points..

SR.NO. COMPACT CONTROLLER

1 PXC12.D/E.D
2 PXC22.D/E.D
3 PXC36.D/E.D
MODULAR SERIES(Expandable Type) : We can go with higher
no. of I/O in this series. This means we can add-on I/O modules
& integrate the program

CPU I/O Expandable


modules

SR.NO. MODULAR CONTROLLER

1 PXC50.D/E.D
2 PXC100.D/E.D
3 PXC200.D/E.D
3rd PARTY INTEGRATORS :This range facilitate to integrate 3rd
part services with BMS. Example, PLC of any brand can be
brought & integrate to the BMS thru this 3rd party Integrator.

1 PXC00.U

2 PXC00.D/E.D
MANAGEMENT LEVEL # 3:
Level-3 It covers the final building management level window,
comprises of Software & hardware supervisory controllers.
SOFTWARE FOR BMS CONTROL SYSTEM-
Salient features:-
 3 level password security
 Automatic database save & restore
 Alarm & Event log
 System diagnostics
 Backup of data/Program
 Clock Synchronization
 History records & Trend logging
 Reports & logs etc.
NETWORK/SUPERVISORY CONTROL UNIT(BACnet Router) RANGE -
 PXG3.L
 PXG3.M
HAND HELD TERMINAL : This enable us to access any one DDC controller
to read, write and modify the parameters on a bus by plugging the POT in
the service port available in any one of the controller.
 PXM20
 PXM20-E

Display:
 High resolution graphic display
(120 x 64 mm, 240 x 128 Pixel)
 Sharp and exact texts with various big fonts
 High brightness CFL back light
 Adjustable display contrast

Operation with logic grouping:


 6 line buttons, page-up, page-down
 ESC (undo and go up button)
 OK, +, -
 Info key
PROJECT : ABC

FOLLOWING KEY ATTIBUTES OF THE BMS DESIGN ENVISAGED AS


PER CONTRACT.

1 : BUILDING APPLICATIONS:

2 : INPUT-OUTPUT SUMMARY

3 : SYSTEM ARCHITECTURE
1. BUILDING
APPLICATIONS:

HVAC Utilities being DCR


System
System
monitored /
controlled by Pneumatic system
Pneumatic
Pressure BMS monitoring
Valves FAS &
Air Tight
Doors / Blast Fire Fighting
Doors System
Sewage water UPS System
system monitoring

Water
Management
Air Filtration
DG System O2 System
System CO2 Removal
monitoring Replenishment System
System
2. INPUT-OUTPUT
SUMMARY:
S No SERVICE DESCRIPTION AI BI AO BO SUBTOTAL
A AIR COOLED CHILLERS & PUMPS(2+3sets) 20 56 0 30 106
B AHUs(Service area-05sets &Office area-09sets) 60 42 23 14 139
C AIR WASHER & SPRAY PUMPS(1+1set) 2 16 0 4 22
D VENTILATION BLOWERS(FAB-2+2sets & EAB-2+2sets) 28 100 16 88 232
E CO2 REMOVAL SYSTEM(1+1set) 70 142 14 64 290
F AIR FILTERATION SYSTEM(1+1set) 12 192 0 168 372

G DG SETS,DG BLOWERS,OIL PUMPS &TANKS(1+1 sets) 15 59 0 43 117


H UPS UNITS(2+2 sets) 4 10 0 0 14
I AIR COMPRESSOR UNITS(2+2sets) 2 4 0 0 6
J OXYGEN REPELISHMENT SYSTEM(1+1sets) 4 0 0 4 8
K STRONG AUTOMATIC DOORS(DOUBLE LEAF)(4+3sets) 0 56 0 56 112
L STRONG AUTOMATIC DOORS(SINGLE LEAF)(16sets) 0 64 0 64 128
M AIR TIGHT AUTOMATIC DOORS(DOUBLE LEAF)(1sets) 0 8 0 8 16
N AIR TIGHT AUTOMATIC DOORS(SINGLE LEAF)(9sets) 0 36 0 36 72
O DCR SYSTEM(1+1sets) 3 72 0 45 120
P FIRE FIGHTING & FIRE ALARM SYSTEM(1+1sets) 3 11 0 0 14
Q WATER SUPPLY SYSTEM(1+1sets) 0 136 0 50 186
R WATER SUPPLY SYSTEM FOR ADMIN AREA(1+1sets) 0 32 0 14 46

TOTAL DATA POINTS 223 1036 53 688 2000


3 :SYSTEM
ARHITECTURE: OFFICE
BUILDING

LAN
ETHERNET S/W BACnet / Ethernet IP
BACnet / LonTalk

ROUTER-1
------------- (OB)
DDC-01 DDC-02 DDC-03 DDC-08 --- ---
LIU --- M/C LIU --- M/C

A B
AREA
BACnet / LonTalk AREA
BACnet / LonTalk
ROUTER-2 --- --- ROUTER-1
------------- (O END) M/C --- LIU LIU --- M/C (1 END) -------------

DDC-10 DDC-11 DDC-12 DDC-21 DDC-32 DDC-24 DDC-23 DDC-22

BACnet / Ethernet IP BACnet / Ethernet IP

--- ---
DDC-09 M/C --- LIU LIU --- M/C DDC-22
THANK YOU