Ports
Standard setting:
Case drain port L
A10VODFR/31: 280 bar
A10VODFR/52: 250 bar
Flow control FR
p = 10 - 22 bar)
Standard setting:
p = 14 bar
X - Pilot pressure port
Suction port S
(viewed A10VO, BR 31, clockwise)
DR Pressure port
Damping orifice
Control piston
(Circuit diagram
viewed for A10VO,
series 31) Counter balance piston and mechanical spring
FR
DR
DR - axis
FR - axis
p = 15 bar
A10 VO 74 DFR(1)
n = 1500 rpm
p = 15 bar
Stand by = 20 bar
pHD
px
X
DFR1
FR
FR - axis
DR
DR - axis
Damping orifice DR - FR
(Standard: 0,6 mm,
Slit in longitudinal direction: orifice opened
Slit in cross direction : orifice closed, SO 74)
Attention:
or
Differential pressure
measurement with
swivel angle !
Procedure:
FR - flow control blocked !
High pressure line closed !
Adjusting of DR pressure control X
with setting value !
FR
Measuring - point 1: High pressure
(measurable at plug of DR valve axis)
DR
Adjustment DR : each rotation
app. 50 bar !
- 50 bar
+ 50 bar
X
Measuring - point 1: load pressure
corresponding to pressure of port X !
( LS - signal )
FR
- 16 bar
+ 16 bar
DFR - design
With decompression orifice !
(DFR: Standard: 0,35 mm
glued in place, fastened with Loctide)
DFR1 - design
Without decompression orifice !
(DFR1: closed, without drilling)
FR
DR
Special design (Stabilization):
SO 116: Return line orifice 1,3 mm
SO 229: Return line orifice 1,5 mm
SO 231: Return line orifice 2,2 mm
SO 277: Return line orifice 1,0 mm
SO 381: Return line orifice 0,8 mm
SO 617: Return line orifice 0,6 mm