ENTERTAINMENT CENTER STANDARD STUDY

Indoor sports- indoor cricket, badminton, tennis, table tennis.


skating

STANDARDS NATIONAL INTERNATIONAL


Acoustics For partitions between rooms in Class It should have ambient noise level
C and most corridors, a Row of 35 dB less than 40 dB
for the partition itself is adequate

Lighting Lighting system should be flexible. High Lighting intensities should be above
luminance of 1000-2000 lux is required 50-foot candles for tournament and
club play and above 30 foot-candles
for recreational play.

Toilets/ changing rooms Male public: 1 per 100 persons up to Generally 1 to 1 1/2 showers per
400 persons; court is sufficient in the men's
Female public : 3 per 100 persons up locker room ; 3/. to 1 shower per
to 200 persons; court (with a private dressing
booth) is generally sufficient for the
women's locker room.

Materials
Fire and safety buildings should be provided with and
protected by fire extinguishers, wet risers,
automatic sprinkler installations, etc. These
shall be in accordance with the set
standards.
Gymnastics and free solo -
Trampoline, rock climbing, , Zumba

STANDARDS NATIONAL INTERNATIONAL

Acoustics Sound absorbent materials play a


useful part in reducing the built-
up or air-borne noise at source.
Lighting Localized lighting may be
appropriate the range of lux
being 200-300-500
Toilets/ changing rooms Male public : 1 per 100 persons
up to 400 persons;
Female public : 3 per 100
persons up to 200 persons;

Materials This is the most popular way to For outdoor climbing walls, the
start your climbing journey. Walls most commonly used material is
are mounted across the world 12 inches of fine gravel (pea
with set standards and faces with gravel) because it will not
different difficulty levels. IMF has deteriorate, wash away or retain
a world class wall in Delhi that moisture the way mulch, wood
many climbers use as a favorite chips, and sand do in certain
practice ground conditions.
Fire and safety
Enclosed activities-
Vr set up, escape room, flight simulator, Bar , Snow world

Standards National International

Acoustics The recommended


minimum sound
reduction (Db) between
rooms in different classes
is 45 dB subject to the
following.

Lighting The lighting should be


design ed to create
appropriate atmosphere.
Amount of lux being 50-
200

Toilets/ changing rooms Male public : 1 per 100


persons up to 400
persons; and for over 400
persons,add at the rate of
1 per 250 persons or part
thereof
Female public : 3 per 100
persons up to 200
persons;

Materials
Fire and safety
Target Sports/ activities- bowling, laser tag , slot machines , arcade
arena, archery , Billiards

Standards National International

Acoustics The recommended minimum sound


reduction (Dw) between rooms in
different classes is 45 dB subject to
the following.

Lighting The lighting should be design ed to


create appropriate atmosphere.
Amount of lux being 50-200

Toilets/ changing rooms Male public : 1 per 100 persons up


to 400 persons; and for over 400
persons,add at the rate of 1 per 250
persons or part thereof
Female public : 3 per 100 persons
up to 200 persons;

Materials

Fire and safety Fire exthinguishers must be put less


than 10m in height
Food and Refreshments –
RESTAURANT, CAFÉ, BAR, FOOD COURT -

Standards National International

Acoustics The recommended


minimum sound
reduction (Db) between
rooms in different classes
is 45 dB subject to the
following.

Lighting The lighting should be


design ed to create
appropriate atmosphere.
Amount of lux being 50-
200

Toilets/ changing rooms Male public : 1 per 100


persons up to 400
persons; and for over 400
persons,add at the rate of
1 per 250 persons or part
thereof
Female public : 3 per 100
persons up to 200
persons;

Materials
Fire and safety