PRE ENGINEERED STEEL BUILDINGS
Aesthetic Appeal
Faster Completion
Economical
Seismic Resistance
Ease of Expansion
Maintenance Free
Large Clear Spans
Controlled Quality
Hassle Free
Self weight Self weight
30% lighter More heavy
Primary Member is tapered Primary members are Hot
section rolled “I” section
Secondary members are light Secondary members are “I”
weight rolled framed “Z” or “C” section which are
and “C” section heavy in weight.
Delivery – average 6 to 8 Delivery- average 20 to 26
weeks weeks
Foundation-simple design, Foundation- expensive,
easy to construct & light wt. heavy foundation required.
Erection cost and time- Erection cost and time- 20%
accurately known more than PEB
Erection process is easy, fast, Erection process is slow and
step by step extensive field labor is
required.
Seismic Resistance- low Seismic Resistance- rigid
weight flexible frames offer heavy weight structures do
higher resistance to seismic not perform well in seismic
forces zones
Overall price -30%lower Overall price - Higher Price
architecture-achieved at low per square meter.
cast Architecture- achieved at
higher cost
COMPONENTS
MAIN FRAME
PRIMARY MEMBERS (Main Frame)
Columns
Rafters
SECONDARY MEMBERS
Purlins
Girts
SHEETING
Roof
Wall
Fascias etc
Accessories
Ventilators
Sky Lights
Misc.
OTHER MAJOR COMPONENTS OF PEB
STRUCTURAL
PARTIONS
FASCIAS CANOPIES
PRE-ENGINEERED BUILDINGS NOMENCLATURE –
STANDARD FRAMING SYSTEMS
Y
Z X
Load 1
Y
Z X
Load 1
ANALYSIS :-
1.Dead load calculations
2.Live load calculations
3.Wind load calculations
LOAD COMBINATIONS :-
A. 1.5(DL + LL)
B. 1.5(DL + WL)
PLOT THE MAXIMUM SFD AND BMD OF THE MEMBERS :-
DESIGNING :-
1.Design of the primary members
2.Design of connection plate
3.Purline Design
4.Girt Design
5.Base Plate
6.Anchor Bolt design for Moment Condition
7.Anchor Bolt design for Shear Condition
8.Cranes Design
Optimisation of frame
Basic Frame
• Width of the frame = 16 M
• Height of the frame = 8 M
• Length of the frame = 35 M
• Wind speed V = 43 M/S
• Bay spacing L = 7 M
• Slop of roof I= 1:10
• Seismic zone = 4
LOAD COMBINATION:- 1.5(DL + LL)
LOAD COMBINATION:- 1.5(DL + LL)
3 4
1 2
LOAD COMBINATION:- 1.5(DL + WL)
LOAD COMBINATION:- 1.5(DL + WL)
3 4
1
2
2
DESIGN RESULT : BY LIMIT STATE
METHOD
DESIGN RESULT: BY WORKING STATE
METHOD
•USING SAME SECTION THAT USED IN LIMIT STATE
METHOD
DESIGN RESULT : BY WORKING STATE
METHOD
ERECTION SYSTEM
Sheeting preparation
Sheeting the walls
Sheeting the roofs
Miscellaneous trimmings
Fascia