Download as ppt, pdf, or txt
Download as ppt, pdf, or txt
You are on page 1of 14

Design on SMPS Transformer

(Topology and Material Selection)


Typical locations where cores are used
Core Material
• Purpose of the core is:
– To reduce the magnetizing current. (For topologies
such as Forward, Bridge etc we need the magnetizing
current to be as small as possible. For fly-back
topology, though the magnetizing current is used to
transfer energy, the size of the transformer will be
very large to get the required inductance if a core is
not used.)
– To improve the linkage of the flux within windings if
the windings are separated spatially.
– to contain the magnetic flux within a given volume
– In magnetic amplifier applications a saturable core is
used as a switch.
Core Material
• Different types of material used for cores
– Iron
– Silicon Steel
– Nickel-Iron
– Iron-Cobalt
– Ferrite
– Molybdenum
– Met-glas
Core Material
• Salient characteristics of a core material
are
– Permeability
– Saturation flux density
– Coercive force
– Remnant flux
– losses due to
• Hysteresis
• Eddy Current
B-H loop of a magnetic material
B-H Minor loops
Core Material
• The power loss is a function of frequency and
the ac flux swing and is given by the equation

• P = K1 * (frequency)K2 * (Flux Density)K3

• Typical power loss for different material are


given below:
Material Type Loss
(mw/cm^3)
Phillips, Ferrite 3C90, µ = 110
2300
Phillips, Ferrite 3C81 220
µ = 2700
Phillips, Ferrite 3F3 120
µ = 2000
10 @ 200 G,500 KHz
Phillips, Ferrite 3F4
180 @ 1000G,100KHz
µ = 900 1600 @1000G,500KHz

Frequency = 100 KHz ; B = 1000 Gauss.


Material Type Loss (mw/cm^3)

EPCOS, Ferrite N27, µ = 2000 231.5


EPCOS, Ferrite N67, µ = 2100 68.57
EPCOS, Ferrite N87, µ = 2200 50.7
Met-glas, 2714 AS 105
Met-glas , Powerlite, C core 840
Met-glas , Micolite µ = 245 560
Met-glas , Micolite µ = 270 630

Frequency = 100 KHz ; B = 1000 Gauss.


Material Type Loss
(mw/cm^3)
Moly Powder Permalloy µ = 12 870
Moly Powder Permalloy µ = 60 360
Moly Powder Permalloy µ = 200 1440
Magnetics , Material K µ = 1500 110
Magnetics , Material R µ = 2300 70
Magnetics , Material P µ = 2500 125
Magnetics , Material F µ = 3000 225
Magnetics , Material H , µ = 15000 2200

Frequency = 100 KHz ; B = 1000 Gauss.


Material Type Loss
(mw/cm^3)
Magnetics Tape wound 870
Supermalloy
Magnetics Tape wound 360
Square-Permalloy
Magnetics , Material P µ = 2500 125
Magnetics , Material F µ = 3000 225
Magnetics , Material H , µ = 15000 2200

Frequency = 100 KHz ; B = 1000 Gauss.


Performance factor