ARYA COLLEGE OF ENGINEERING , JAIPUR (RAJ.

Presentation ON Residential Building

Presented by :- Guided by :-
Vishnu Saini Mr. Kapil Karadia
7th Sem. , 4th Year Head of Civil Department
Training Certificate
CONTENTS
 SITE INFORMATION
 SITE LOCATION
 SITE MASTERPLAN
 PCC
• GRID LINE LAYOUT (Column
Centerline)
• LAYING OF PLANKS (Bhatta)
• CASTING OF PCC
 FOOTING
• LAYOUT OF FOOTING ON PCC
• LAYING OF MASH ON PCC
• MAKE L SHAPE ON CORNER OF MESH
• FOOTING CASTING
 COVER BLOCK
 EXPANSION JOINT
 CHIAR BAR 3
SITE INFORMATION

COMPANY NAME :- KEDIA GROUP LTD.


PROJECT NAME :- KEDIA THE SEJASTHAN
CONTRACTOR NAME:- Mr. Arjun Chaudhary
PROJECT MANAGER NAME :- Mr. Prashant Kataria
STRUCTURAL CONSULTANCY NAME :- Prime tech design consults
CONSTRUCTION AREA :- 11.67 lac Sq. feet
CONSTRUCTION LOCATION:- Near Omaxe city, Ajmer road, Jaipur,
Raj.302026
SITE LOCATION
5
SITE MASTERPLAN

6
GRID LINE LAYOUT
FOR PCC
7
PCC
SHUTTERING
SETUP

8
GRID LINE LAYOUT
PLAN

VILLA PLAN

VILLA GRID LINE


LAYOUT
PCC CASTING

• The mixture of cement, fine • Material used :- Cement,


aggregate (Sand) and coarse Sand, Aggregate, Water,
aggregate is called as Plain Chemical admixture and
cement concrete Mineral admixture etc.
• PCC is concrete without • Tool Used :- Spade, Bucket,
reinforcement. Concrete mixture tray and
machine, Needle Vibrator,
• PCC is constructed to
Trowel, Spackle Knife and
transfer the load to the soil Straight edge etc.
below.
• Generally concrete used in
PCC Casting :-
M15 ( Compressive Strength
of Concrete, 15N/mm^2)

10
FOOTING PLAN

11
Footing layout
FOOTING

FRONT VIEW TOP VIEW

• Footing is a part of foundation which is most important PCC SIZE :- 6’6”X6’0”


because the whole building stays on footing. Footing is
FOOTING SIZE :- 7’2”X6’8”
used to transfer the loads.
• The footing is 4” inside the outer part of the PCC.
Height of rec. shape of footing :- 8”
Total height of footing :- 24”
Height of trapezoidal shape :- 16”
13
Laying Steel Mesh
on PCC

14
CONCRETE & STEEL GRADE DETAILS

 Concrete Grade:- M25(Mix. Design 25 N/mm2


 Steel Grade :- Fe 500D ( for 8mm, 10mm bars)
AND
Fe 550D (for all other bars like 12mm, 16mm etc.)
 Clear Cover :- Top – 50mm
Bottom – 50mm
Side - 50mm
NOTE :- For footing starting from ground, depth of footing shall be 4’-0” from
the natural ground level.

16
WHY WE USE ISOLATED FOOTING?

• Isolated footings are commonly used for shallow foundation in order to carry
and spread concentrated loads, caused for example by columns or pillars.
• Isolated footings are used to distribute the load of a structure evenly to the
soil. They provide stability and prevent settlement.
• Isolated foundations distribution the loads from a column or point load over a
large area of soil.

17
CONCRETE VOLUME CALCULATION FORMULA

18
CLEAR COVER

CLEAR COVER DETAILS

19
EXPANSION JOINT

• An Expansion joint is a mid-structure


separation designed to relieve stress on
building materials caused by building
movement.
• Building movement at expansion joint
is primarily induced by thermal
expansion and contraction caused by
temperature changes and also caused
by wind load.
CHAIR BAR

• Chair bar refers to support bar placed


and tied between the upper and lower
reinforcement bars to maintain the gap
and stability of reinforcement.

21
22