Basic information

CMApp No. CM 9220

Related change (if simultaneous implementation necessary)

Link to stored CAD data "V:\pas\DAG\EVA2\06-CS-AST\04_Serie\05_Untersuchung-Anfrage\2023-06-20_ANF_GEHAEUSE_Klemmen"

Scrapping old stock (TV) yes

- if scrapping necessary – reason: function failure of assembly possible

Customer claim / official complaint available

- if official claim exists, number:

Additional documents

Released by: Pfaff, Dieter Release date: December 08th Version: 15 Seite 2
Change description
Index Volumen [cm³]
No Article no. Article description Link to CAD data
current new current new

1 00180273 GEHAEUSE AU SW DAG X296 CSLI AST "V:\pas\DAG\EVA2\06-CS-AST\04_Serie\05_Untersuchung-Anfrage\2023-06-20_ANF_GEHAEUSE_Kle 4.1 40,62 40,63
mmen\00180273_M_GEHAEUSE_AUSSEN_CS_LI____________________S04_A2968304600_V01_A
NF_20230620_MSK.stp"
2 00180295 GEHAEUSE AU SW DAG X296 CSRE AST "V:\pas\DAG\EVA2\06-CS-AST\04_Serie\05_Untersuchung-Anfrage\2023-06-20_ANF_GEHAEUSE_Kle 4.1 40,62 40,63
mmen\00180295_M_GEHAEUSE_AUSSEN_CS_RE____________________S04_A2968304500_V01_
ANF_20230620_MSK.stp"

3 ribs added

offset surface by
+0,13mm

00180273 (LI) shown


00180295 (RE) mirrored

Determination / Problem Open / close function was not given on some parts
Cause (if known) “SCHLIESSKLAPPE” stuck when opened/closed because of friction between soft component and surrounding (“GEHAEUSE AU”)
Solution to be evaluated Ensure enough clearance between “SCHLIESSKLAPPE” and “GEHAEUSE AU” to prevent contact

Released by: Pfaff, Dieter Release date: Dece Seite 3


mber 08th Version: 15
Change description
Index Volumen [cm³]
No Article no. Article description Link to CAD data
current new current new

1 00180273 GEHAEUSE AU SW DAG X296 CSLI AST "V:\pas\DAG\EVA2\06-CS-AST\04_Serie\05_Untersuchung-Anfrage\2023-06-20_ANF_GEHAEUSE_Kle 4.1 40,62 40,63
mmen\00180273_M_GEHAEUSE_AUSSEN_CS_LI____________________S04_A2968304600_V01_A
NF_20230620_MSK.stp"
2 00180295 GEHAEUSE AU SW DAG X296 CSRE AST "V:\pas\DAG\EVA2\06-CS-AST\04_Serie\05_Untersuchung-Anfrage\2023-06-20_ANF_GEHAEUSE_Kle 4.1 40,62 40,63
mmen\00180295_M_GEHAEUSE_AUSSEN_CS_RE____________________S04_A2968304500_V01_
ANF_20230620_MSK.stp"

 There are two cavities on mold

00180273 (LI) shown


00180295 (RE) mirrored

Determination / Problem Open / close function was not given on some parts
Cause (if known) “SCHLIESSKLAPPE” stuck when opened/closed because of friction between soft component and surrounding (“GEHAEUSE AU”)
Solution to be evaluated Ensure enough clearance between “SCHLIESSKLAPPE” and “GEHAEUSE AU” to prevent contact

Released by: Pfaff, Dieter Release date: Dece Seite 4