Sample Calculation 1

Diameter of Bearing: 150 h6 (0.000/-0.025) mm


Upper Limit Tolerance: 150 -0.000 = 150.000 mm
Lower Limit Tolerance : 150 -0.025 = 149.975 mm

Diameter of Bore: 150 S7(-0.085/-0.125) mm


Upper Limit Tolerance : 150 -0.085 =
149.915 mm
Lower Limit Tolerance : 150 -0.125 =
149.875 mm
Lower Value
= 149.875 – 150.000 = - 0.125mm Results fall in negative range, So
Higher Value it is an INTERFERENCE FIT
= 149.915 – 149.975 = - 0.060mm
Sample Calculation 2
Diameter of Bearing: 120 h6 (0.000 / -0.022) mm
Upper Limit Tolerance: 120 -0.000 = 120.000 mm
Lower Limit Tolerance : 120 -0.022 = 119.978 mm

Diameter of Bore: 120 H7(+0.035 / +0.000)


mm
Upper Limit Tolerance : 120 +0.035 =
120.035 mm
Lower Limit Tolerance : 120 +0.000 =
120.000 mm
Lower Value
= 120.000 – 120.000 = 0.000mm Results fall in positive range, So
Higher Value it is a CLEARANCE FIT
= 120.035 – 119.978 = + 0.057mm