Professional Documents
Culture Documents
Cerberus Pro en
Cerberus Pro en
Cerberus Pro en
www.siemens.com/cerberus
Cerberus PRO – enjoy protecting
3
Very simple systems Fire brigade calling systems
Ensuring comprehensive
safety with powerful panels
Cerberus PRO fire control panels Protecting the smart way Realizing solutions simply
combine high security Cerberus PRO protects people and assets and quickly
standards right from the start. Thanks to auto-con- Cerberus PRO provides a competitive
with the latest technology. figuration even during the construction range of control panels. They are the per-
Competitive for simple
phase. How does it work? The control fect choice for a variety of applications,
applications,
yet powerful enough for every
panels automatically configure and from small and simple to large and com-
application – they are the ideal import data from all connected detectors plex. Each panel offers unique features
choice whatever the size and and peripheral devices. They also auto- aimed at putting a system into operation
com- matically assign them to zones. quickly and safely from one access point.
plexity of your project.
In addition, all control panels have inte- Creating very large and
grated safety functions like the degrade complex networks
mode. It ensures that even in case of a With Cerberus PRO, you can protect very
processor failure, a detector communi- large and complex campus facilities.
cates an alarm to the panel, setting off Powerful cause and effect programming
all connected sounders including loop allows solutions with the added benefit
sounders. It also activates the remote of full EN 54 compliance.
transmission to the fire brigade and sets
the I/O to the predefined status.
In addition, Cerberus PRO offers an EN 54-
approved, industrial LAN technology –
Control panels and fire terminals also also called backbone (C-WEB/LAN). The
offer a standby functionality. In case the backbone connects up to 14 clusters and
connection to the management station or networks up to 64 panels. It also allows to
to another station should fail, they take optimally adapt Cerberus PRO to any
over display and operation functionality. building or process structure, and to eas-
ily realize campus-wide solutions.
4
Plant control Phased evacuation Smoke and fire damper control
– Plant control shuts off, ventila- – Areas most at risk are evacuated – Smoke control systems and fire dampers
tion systems shut down, first, followed by adjacent areas are activated
doors – Phases can be preset via timing – Dampers, smoke controls, ventilation
controlled and lifts returned functions motors, etc. are monitored to warn user
– Some plants may only be shut – They can also be manually of any critical device that has failed
down after a time delay or if overridden – Intensive programming from a complex
fire by security staff or fire brigade cause and effect matrix required
is detected in a particular area – Sophisticated cause and effect
– Basic cause and effect program- programming required
ming required
5
Providing fast, reliable detec-
tion with patented technology
Relying on detection without Choosing from a broad portfolio
Highlights
deception All Cerberus PRO detectors are backed
Demanding applications require exceptio- by the application know-how we h ave ■ Broad detector portfolio –
nal detection technology. Cerberus PRO gained with projects around the world – meet all requirements from
detectors with our unique ASAtechnology and with more than 60 million detectors sensitive to robust
(ASA = advanced signal analysis) offer a installed worldwide. The point detector ■ ASAtechnology with differen t
very fast and highly reliable d etection range comprises detectors for standard parameter sets – set detector
response. Being immune to deceptive as well as for demanding applications. to specific environmental
p h en o m en a such as steam, dust or gas, conditions
they prevent unnecessary downtimes
Standard applications have a low risk of ■ Unsurpassed detection tech -
and costs caused by false alarms.
fire as well as few deceptive phenomena. nology – immune to deceptive
They thus present little risk to life and pro- p h en o m en a
From sensitive to robust, you can choose perty. These applications include offices, ■ Evaluation of the fire criteria
from different preprogrammed parameter conference rooms, corridors and stairwells. –
sets to m e et the expected enviro n men tal smoke, heat and carbon
condition of your application. This means monoxide
Point detectors with ASAtechnology are
that in case of a fire, the detector reacts especially suitable for demanding appli- ■ Siemens has 160 years experi-
more sensitively – and in case of decep- cations with a high risk of fire and many ence in fire safety – more than
tive phenomena, the detector is more deceptive phenomena. Applications 60 million detectors installed
robust. include hotel rooms where the detector worldwide
must be mounted close to the bathroom
door, multi-purpose halls and large
Detecting carbon monoxide
conference rooms.
Cerberus PRO also provides a detector
for all fire criteria: smoke, heat and car-
bon monoxide (CO). The additional CO
sensor ensures earliest detection of all
CO-generating fires. It can also detect
CO independently from fire thanks to
its autonomous CO alarm channel.
6
Offering a wide range
of special detectors
Linear smoke detector Aspirating smoke detection
Highlights
In areas with limited access such as in These detectors are ideal for areas that
high bay warehouses or atria point type require very high sensitivity such as com- ■ Broad range of special d etec-
detectors can prove impractical. Here, lin- puter suites or for areas that have limited tors – to cover your application
ear smoke detectors are the ideal choice. accessibility or a complex structure such
■ Linear smoke detector – for
Cerberus PRO linear smoke detectors as high bay automated storage facilities.
high ceiling areas with limited
work on a reflection principle. This means Aspirating smoke detectors from Siemens accessibility
that they only have to be connected at have an optical dual-wavelength detection
o n e end, saving cables and installation technology that quickly and reliably dif- ■ Flame detection – for areas
costs. ferentiates between smoke and deceptive with highly flammable
phenomena. materials
Flame detection ■ Ex detectors – for areas
Areas containing highly flammable sub-
materials, such as engine test beds or Radio fire detection ject to explosion hazards
flammable stores, are better covered with As wireless devices can be quickly and ■ Aspirating smoke d etecto rs
flame detectors. The Cerberus PRO flame freely positioned and repositioned, th ey –
detector range includes both single- are ideal for rooms or buildings of for demanding applications
channel IR for simple applications as well historical value, with aesthetic or archi- that require very early fire
as 3-channel IR for areas with deceptive tectural restrictions or for tem porary detection
phenomena such as halogen lamps, installations. With SWING, Siemens sets ■ Radio fire detection – for
bright sunlight or welding. new safety standards by combining th e areas
highly reliable mesh technology for safe where cabling is difficult or
wireless transmission with the unique not suitable due to structural/
Ex detectors ASAtechnology for high d etection aesthetic reasons
Cerberus PRO offers a complete range reliability.
of detectors and other peripheral devices
that can be used to protect areas subject
to explosion hazards such as oil refineries,
flour mills or battery rooms.
7
Connecting smart peripher-
als to the detection loop
Sounders Loop-powered floor repeater
Highlights
Loop-powered sounders are available as terminals and mimic displays
wall-mounted devices in red or white. A unique feature of Cerberus PRO is the ■ A wide portfolio of
They all have an adjustable sound output repeat panel indication via loop-powered peripheral
of up to 99 dBA and 11 selectable tones. floor repeater terminals. This enables devices – all connected via
Any two tones can be selected to provide C-NET
you to add important information in
escalation from alert to evacuation. a most cost-efficient and secure way. ■Loop-powered sounders –
Future additions can be incorporated with 11 different tones
Sounders with supplementary by simply tapping off the nearest ■ Loop-powered alarm sounders
optical indication detector, call point, sounder, etc. The with supplementary optical
floor indication – for visual warning
The FDS229 alarm sounders with supple-
mentary optical indication provide all repeater terminals come in two models:
■ Sounder base – combines a
The FT2011 gives a detailed overview of
the features of the loop-powered detector with a sounder pow-
all alarms and messages. In addition, the
sound- ers mentioned above – plus an ered by the C-NET
FT2010 offers the same main operating
additional integrated flashing optical Loop-powered floor rep e ater
functions as the control panel. A loop- ■
indication. They are available in red and terminals – to safely display
powered mimic display allows mimic dia-
orange and are very light intense (max. information where needed
grams to be added to the system as well.
3.2 cd).
Sounder base Input/output modules
Cerberus PRO detectors can be used with The Cerberus PRO system allows connec-
the DBS720 sounder base, providing a tion of the full range of modules from
neat detector/sounder combination as a Siemens including: single input module,
single unit. The sounder base has th e single input and output module, four way
same features as the wall sounders and input module, four way input/output
a maximum sound output of 88 dBA. module (incl. AC 230 V rated contacts)
as well as a dual conventional zone or
dual sounder circuit controller (requires
DC 24 V supply).
8
Yesterday Power supply Today
Communications C-NET
Power supply
9
Cerberus PRO – enjoy protecting
Powerful control panels, clever fire detectors and smart peripheral devices.
This is what our comprehensive Cerberus PRO family offers. The brief overview
below demonstrates the most important system components.
Danger
Remote access management
with Cerberus- system from
Remote Customer network Ethernet Siemens
Security module
(firewall)
NK8237
Security module
(firewall)
NK8237
Cerberus Mobile
Ethernet switch
FN2008-A1 Backbone (C-WEB/LAN)
Ethernet switch Ethernet switch Ethernet switch
FN2008-A1 FN2008-A1 FN2008-A1
Sounder base
DBS720
C-NET
Fire control panel Fire control panel Fire control panel
FC723 FC722 FC724
Cluster (C-WEB/SAFEDLINK)
Fire control panel
Aspirating Floor repeater FC726
smoke detectors terminal FT2010 Fire terminal
FDA221 FT724
FDA241
Alarm indicator
FDCAI221 Heat detector
HI722 (max) Fault transmission
Input module
Alarm transmission FDCI222
Sounder
interbase DBS721 Floor repeater
display FT2011
Sounder interbase
with supplementary Fire control panel Heat detector
optical indication
DBS729
C-NET Alarm sounder
ASA neural FC724 HI720
fire detector (max + RoR)
with supplemen- OOH740
Smoke Multi-sensor Input/output tary optical indi- SWING
detector fire detector module cation radio gateway
OP720 OH720 FDCIO222 FDS229- FDCW241 Stub line
R ASA neural fire
and CO detector C-NET
OOHC740
SWING
radio neural
Extinguishing fire detector Smoke
control unit XC10 FDOOT271 detector Multi-sensor detector Flame detector
OP720 OOH740-A9-Ex FDF241-9
SWING radio
manual call
point
FDM273
10
Benefits
Unique safety features
Cerberus PRO provides a great number of safety features for earliest detection of fire, heat and smoke as well as fast reaction in case of an event.
Moreover, the detector range covers all applications from standard to sophisticated and ensures reliable detection with no false alarms. This translates
for
you into ensured business continuity and peace of mind.
Cost efficiency
Cerberus PRO also stands for less costs. First of all, ensured business continuity results in both cost and time savings, as you will have no process
inter-
ruptions. Moreover, Cerberus PRO is a future-proof investment that lets you benefit from reduced planning efforts as well as low life cycle costs.
The information in this document contains general descriptions of technical options available, which do not always
have to be present in individual cases. The required features should therefore be specified in each individual case at
the time of closing the contract. The document contains a general product overview. Availability can vary by
country. For detailed product information, please contact the company office or authorized partners.
© Siemens Switzerland Ltd, 2015
Our world is undergoing changes that force us to think “We are the trusted technology partner for
in new ways: demographic change, urbanization, global energy -efficient, safe and secure buildings and
warming and resource shortages. Maximum efficiency infrastructure.”
has top priority – and not only where energy is
concerned. In addition, we need to increase comfort for
the well-being of users. Also, our need for safety and
security is constantly growin g. For our customers, success
is defined by how well they manage these challenges.
Siemens has the answers.
www.siemens.com/buildingtechnologies