Professional Documents
Culture Documents
1-Chromai-Chromatographic Development and Analysis of Major Module Types and Principles
1-Chromai-Chromatographic Development and Analysis of Major Module Types and Principles
introduction + maintenance
— 2023 —
www.chromai.com
02 Leaps Product
03 Single Module
04 EyouLab CDS
06 6
Maintenance
公司简介
• Chromai is a high-tech enterprise engaged in the R&D, production, sales and service of analytical testing instruments
Company Profile
and medical diagnostics. It is a member of China Instrument and Meter Association and China Medical Device
Industry Association. The company focuses on the full combination of scientific instruments, automation and
intelligence, and serves the fields of analysis and testing and medical testing.
• The company insists on independent innovation and takes the revitalization of national industry as its own
responsibility. The vision is to fundamentally change the global industry market structure, make China's creations
famous all over the world, and build Konomi into an outstanding international brand.
Chromai
Business Direction • Chromai adheres to independent innovation and takes the revitalization of national industries as its
mission. Its vision is to fundamentally change the global industry market structure, make China's
creations famous all over the world, and build Chromai into an outstanding international brand.
Fundamentally break the import monopoly, improve efficiency, reduce costs, and create value for
customers. The company now has Beijing R&D center, Suzhou production base and other
subsidiaries.
• At present, it is mainly aimed at the two fields of general testing and precision medicine:
• General detection field: Leaps series ultra-high performance liquid chromatography system, Pump,
Autosampler, EyouLab CDS and related components and consumables, etc.
• Precision medicine field: Voyager series IVD two-dimensional ultra-high performance liquid
chromatography system, EpoStar series automatic sample processing platform, exclusive
methodology-related reagents, etc.
Company Location
BEIJING SUZHOU
Operation Center And Researchcentre Production Factory
Awards
technology lead
UHPLC
Ultra High Efficiency Columns lower flow rate
vs.
HPLC 1.7μm~5μm can be Use a lower flow rate
0.001~10.00mL/min
selected
Choose a smaller The amount of reagent
repeatability without
loss of samples.
Leaps UHPLC
Column oven
Accurate temperature control,
UVD , DAD detector
optional double valve switching
ELSD , RID , FLD
EyouLab CDS
Regulatory Compliance, Database,
Autosampler
Web Edition
Refrigeration ( +4 ℃ - room data acquisition box
temperature) dual channel
0.1℃
Leaps 2D
Multi-column switching, perfect determination of complex samples
Complex Analysis
Optional matching, perfect compatibility
One Step Faster
Two-dimensional separation, doubling the peak capacity
Easy determination, greatly reducing pre-treatment
Ultra-efficient grade, higher analysis efficiency
Analytical application in
√ natural pharmaceutical ingredients
√ Chinese herbal medicine extract components
√ quality control of traditional Chinese medicine
√ toxic and harmful substances in the environment
√ differential proteomics
√ biopharmaceutical analysis
Leaps Bio
Enabling Efficient Biological Sample Analysis
Bioinert material, corrosion
and adsorption resistant
Bio-inert sample flow path
No adsorption
wash
pump
1-14 PH
Infusion systems for high pressure preparation
Leaps Prep
20-40Mpa
Simple and Flexible Preparation
and Purification
A truly fully automated preparative system
150mL/min
16000 PSI
54*4
A new generation of ultra-high performance liquid chromatography Flexible for more application expansion
online Man-machine
version separation
EyouLab CDS
Data security
The network
connection is
abnormal. The server
is faulty
Data save
Acquisition local
control terminal
Network
recovery
Server
recovery
Data
synchronization
Data is database server
automatically
saved locally
The network
connection is
normal. The server
is normal
Leaps UHPLC – Pump
Leaps Pump
High pressure infusion pump
Isocratic pump
Binary pump
Binary four-channel pump
Quaternary pump
Double ternary gradient pump
Leaps UHPLC – Pump
isocratic pump
Binary High Pressure Gradient
Pump
Quaternary Gradient Pump
Double ternary high pressure mixer
gradient pump
Vent valve Solvent switching valve
switch
Peristaltic pump
two channels
Degasser
isocratic pump
Binary High Pressure Gradient
Pump
Quaternary Gradient Pump P40
Double ternary gradient pump mixer
Vent valve
switch
isocratic pump
Binary High Pressure Gradient
Pump
Quaternary low pressure gradient
pump
Double ternary high pressure
gradient pump
Leaps UHPLC – Pump
Infusion module high pressure UHPLC high-pressure infusion system specification design, using high-pressure
seal
sealing technology to ensure long-term stability and durability
Rinse after standard
configuration
10500 Guaranteed longer life
PSI
Even
durable
Jeweled plunger
rods are more
Sealing ring with
resistant to wear
high pressure
resistance
Leaps UHPLC – Pump
10500
PSI
high
efficiency
40min
Leaps
15min
Leaps UHPLC – Pump
lower
Infusion module pulsation Patented adaptive pulsation suppression technology algorithm,
comprehensively reduces pressure pulsation during infusion
5
PSI
Low
pulsation
better
Infusion module gradient Better gradient precision, accuracy and repeatability
RSD
0.2%
high
reproduce
Accuracy 0.50%
Repeatability 0.20%
Leaps UHPLC - Sampler
Leaps
7725i
Autosampler
7725i
Injection method: importer
Diaphragm injection, stop-flow injection,
valve injection
graphite
rotor
advantage:
Simple structure, easy maintenance,
cheap price ceramic
stator
shortcoming:
Body fixing
Low efficiency, artificial injection bolts
is necessary, poor precision
Leaps UHPLC - Sampler
Leaps
7725i
5μL
Leaps 10μL
Standard 20 microliters
7725i
20 μL other optional
Quantitative loop
50μL
S316/PEEK
100μL
200μL
500μL
1000μL
5000μL
Leaps UHPLC - Autosampler
Leaps
Autosampler
Leaps UHPLC - Autosampler
Autosampler module
automation
Stable operation
Low residue
High precision
Automation
High volume
Cooling function
Leaps UHPLC - Autosampler
Leaps UHPLC - Autosampler
Leaps UHPLC - Autosampler
various
bottle rack
Flexible vial rack options
Leaps UHPLC – Column Oven
Leaps
Column Oven Uniform internal
temperature
more accurate
temperature
Intelligent PID temperature control algorithm, patented forced air circulation
design, the internal temperature field is more uniform; the temperature is more
accurate up to ±0.1°C
60
59.9
65 59.8
Temperature (Celsius)
59.7
59.6
60 59.5
59.4
Temperature (Celsius)
59.3
55
59.2
59.1
50 59
500 550 600 650 700 750 800
time (seconds)
45
40
35
0 600 1200 1800 2400 3000 3600
time (seconds)
Leaps UHPLC – Column Oven
high sensitivity
Temperature Sensor
internal circulation fan
Multi-Column Switching
System
Leakage alarm
Leak Tray
Leaps UHPLC – Column Oven
Leaps
UV-Vis Detector
Leaps UHPLC – Detector
UV-Vis
A − Absorbance
T − transmittance
ε − molar absorptivity
C − Concentration
L − optical path length
Leaps UHPLC – Detector
UV-Vis
Qualitative Analysis :
Known conditions :
time
The characteristic absorption peak of a certain substance is known, that is, ε (λ) is
known, and it is necessary to judge whether the substance exists .
It is known that there is a certain substance, that is, ε (λ) is known, and the test
optical path L is fixed, the concentration C of the substance should be tested .
Leaps UHPLC – Detector
re
UV-Vis
Patented optical structure design ensures excellent signal-to-noise
ratio, and lower dynamic noise and drift
lower noise
± 0.5×10 -5 AU
Leaps UHPLC – Detector
Leaps
DAD Detector
• 2uL total reflection pool, 1024 pixel array (full spectrum scanning)
• 10mm high sensitivity flow cell
• 60mm high sensitivity flow cell ( ×6 times)
• 90mm high sensitivity flow cell ( ×9 times)
Leaps UHPLC – Detector
Chromato convert
Imaging
graphy, optical
Diode
spectrum signal to
Array
data electrical
Detector
processing signal
Leaps UHPLC – Detector
Leaps
DAD
optical path
Leaps UHPLC – Detector
ps
e-dimensional map
Leaps UHPLC – Detector
common points
Follow the Lambert - Beer law to detect the absorbance of the measured sample
Reference wavelength to
The maximum optical
eliminate background
path is 90mm , realizing
excellent interference, drift
correction function
9X signal sensitivity
Leaps
DAD
Comprehensive advantage
60mm
10mm
Leaps UHPLC – Detector
Leaps UHPLC – Detector
eaps
AB 10
ual channel FLD
ata acquisition box Detector
RID
Detector
ELSD
Detector
EyouLab CDS
☆ EyouLab CDS
EyouLab CDS
ODM integration
easy to use Chromai SDK tool integration
Enterprise cloud framework, open IIF development
Easy to use Extremely simple user
kit, based on Chromai advanced
service interface, easy to use and
chromatography software
convenient
Eliminate IT infrastructure technology,
construction, operation and Can be used in LC, GC, IC, LC-AFS,
maintenance equipment and LC-MS/MS and other detection
personnel to invest in the cloud equipment to jointly build a
platform to help you manage data, chromatographic software
rest assured that massive data ecosystem and provide more
storage can be expanded at any support for third-party instruments
time to build a secure private cloud
compliance
Compliant with FDA 21 CFR part
11/GMP/GLP...Network database
Cloud expert version & cloud service version file
method library system can safely store the database
version, effectively ensuring data
Built-in more than security Automatic backup Electronic
100,000 methods signature audit trail User rights
Massive method management IQ/OQ/PQ
resources to share with Powerful
thousands of users,
communicate and Rich in functions, everything is available
discover your value Developed based on mainstream database technology
platform
Compatible with various LIMS and HIS systems
EyouLab CDS
Typical Application – Determination of Panax
Ginsenosides in Ginseng Red Ginseng
• Solution - Ginsenosides
100
pollutants by the US Environmental Protection Agency
Abs
1 2
50
4
12
13
16
15
14
and limits are specified.
8
0
0 5 10 15 20 25 30
Time [min.]
Using Chromai Leaps high performance liquid
chromatography system to determine 16 polycyclic
aromatic hydrocarbons in water can obtain better
Instrument: Leaps series ultra- high performance liquid chromatography system resolution and less baseline noise, and the results are
accurate and reliable.
Column: Chromai PAH, 5µm x 4.6 x 250mm Column temperature: 30°C
Mobile phase: A methanol, B water; (gradient elution) Flow rate: 1.2mL/min
Detection wavelength: 254nm Injection volume: 10μL
Typical application – Determination of 18 amino acids in
hydrolyzate such as feed / milk / meat products
Using the Leaps high-performance liquid phase
• Solution - amino acid
system for PITC pre-column derivatization
method to test the amino acid composition, the
detection speed is fast and the method is
sensitive; the derivation is convenient, the
derivative is single and stable , and the detection
result is accurate. Ultraviolet detection ( 254mm )
has high sensitivity, and both primary and
secondary amino acids can be detected.
[mAu]
DEHP
20
DNOP
DBP
DEP
10
Unscrupulous merchants add plasticizers to foods
instead of palm oil in clouding agents in order to
0
increase the viscosity and stability of beverage
400
mL 7
- diol
25.430µg/mL-1017.200µg/ r=0.999
300 2 Benzyl alcohol Y=1.48417X
mL 8
10.420µg/mL-416.800µg/ r=0.999
Abs
Y=3.56532X
200
3 Phenoxyethanol
mL 9
100
4- Y=113.72681X r=0.999
4 1.004µg/mL-40.160µg/mL
0
Hydroxybenzoate 9
10.060µg/mL-402.400µg/ Y=7.03688X r=0.999
0 10 20 30
[min.]
5 benzoic acid
Time
mL 8
Y=104.14385X r=0.999
6 4- hydroxybenzoate 1.016µg/mL-40.640µg/mL
9
4- Y=95.52889X r=0.999
7 1.032µg/mL-41.280µg/mL
Hydroxybenzoate 9
4- Y=96.93468X r=0.999
8 1.012µg/mL-40.480µg/mL
Hydroxybenzoate 9
4- Y=90.0397X r=0.999
9 2.560µg/mL-102.400µg/mL
Hydroxybenzoate 9
4- r=0.999
10 2.510µg/mL-100.400µg/mL Y=90.12245X
Hydroxybenzoate
9
prehensive advantage
phases are not filtered, or buffer salts are used. Gemstone/ceramic tee
Gem ball
The check valve is the most fault-prone component Ball seat
in the entire liquid phase system, and developing gasket
good usage habits can effectively avoid this problem.
Valve body
This includes:
( 1 ) Use high-quality organic solvents;
( 2 ) The buffered saline solution should be filtered;
( 3 ) If the buffered salt solution is mixed with an
organic solvent, it will cause the precipitation of salt
particles, so it must be filtered;
( 4 ) Install and disassemble correctly, and clean the
one-way valve.
maintenance
deut
eriu
m
lamp
Precautions:
1. Before opening the detector shell, the power cord must be unplugged, and the deuterium lamp must be turned off for more than 15
minutes to avoid burns due to high temperature.
2. Do not touch the glass part of the deuterium lamp directly with your hands to avoid burns and keep the surface of the lamp clean. If the
surface of the lamp is polluted, use gauze dipped in a small amount of isopropyl alcohol to wipe the lamp clean.
Replacement steps:
1. Turn off the detector, unplug the power cord, and ensure that the deuterium lamp is cooled for more than 15 minutes .
2. Use a Phillips screwdriver to remove the screw on the right side cover of the detector, and then remove the right deuterium lamp
protection cover.
3. Unplug the three-pin plug of the old lamp, use a Phillips screwdriver to remove the two fixing screws on the lamp holder of the deuterium
lamp, put on clean white cloth gloves, and take out the entire lamp along the outside direction .
4. Put the new deuterium lamp in the lamp holder, adjust the direction, tighten the screws, and plug in the three-pin plug.
5. Install the light source chamber cover and tighten the screws.
6. Install the shell cover, tighten the screws, and replace the new deuterium lamp , click Replace on the software, the current deuterium lamp
usage time is cleared, and the replacement is completed
Note: It takes 50 hours to reach the best working condition. You can check the working status and energy of the new deuterium lamp through
the workstation .
maintenance
High pressure
infusion pump
Maintenance required by the user:
• cleaning check valve
• Eliminate air bubbles in the pipeline
• Replace vent valve O -ring
• Replacing the Inline Filter Element
• Check the high pressure seal
• Overpressure treatment
• low pressure treatment
maintenance
mixer
system cleaning
The daily cleaning of the instrument should be done well to prevent dust
from affecting the performance of the instrument.
The front panel of the instrument should not be in direct contact with
organic solvents such as acetonitrile and methanol.
pipeline connection
The part of the whole instrument in contact with the liquid is made of
stainless steel, FPE or PEEK , and strong corrosive organic solvents such as
chloroform and tetrahydrofuran cannot be used.
The joints of the instrument pipeline may leak after long-term use or
repeated disassembly and assembly, and users can replace them with the
attached spare parts.
maintenance
Replacement steps:
1. Turn off the module and unplug the power cord.
2. Use a flat-head screwdriver to pry open the fuse
holder and pull it out.
3. Take out the burnt fuse and install a new one on
the fuse holder.
4. Reinstall the fuse holder and snap it tight.
5. Power on the instrument, if the instrument can
be turned on normally, it proves that the fuse has
been replaced correctly.
maintenance
whole system