Agaro Town 3G Cluster Pre DT Analysis Report

You might also like

Download as pptx, pdf, or txt
Download as pptx, pdf, or txt
You are on page 1of 24

AGARO TOWN CLUSTER 3G DT

MEASUREMENT ANALYSIS AND PRE REPORT

Drive Test Done By Girum Tekle


Analysis done by Girum Tekle
Date 27/02/2023
DOCUMENT CONTROL

Date (DD/MM/YYYY) Version Prepared by Remark


27/02/2023 V0.1 Girum Tekle
CONTENTS

INTRODUCTION

Drive Test Result

Analysis

CONCLUTION & RECOMMENDATION


INTRODUCTION

SCOPE AND REALIZATION OF RF OPTIMIZATION

Test Type Test Case Target Remark


3G Short Call Coverage_RSCP <-95dbm>95%(i.e. 89.3%) Not Meet
Quality_EcNo <-13db>95%(i.e. 90.4%) Not Meet
CSSR >=98%(i.e. 97.4%) Not Meet
CDR <=2%(i.e. 1.6%) Meet
UE TX Power >13dbm > 95%(i.e. 96.8%) Meet
CLUSTER INFORMATION
• The Purpose of this report is to analyze the 3G Pre-Coverage, Quality and Call Statistics
Performance of Agaro City. The Cluster Contains total number of 12 site.
INTRODUCTION

Drive Test Result

Analysis

CONCLUTION & RECOMMENDATION


DRIVE TEST RESULT
• server cell coverage, RSCP

• The Pre DT result shows the overall 3G Downlink Coverage Performance is below Target. The result
shows 89.7% of city coverage is less than -95dBm which is bad coverage performance.
DRIVE TEST RESULT
• server cell quality, ECNO

• The Pre DT result shows the overall 3G Downlink quality Performance is below Target. As shown above there
is bad quality performance on the tested route (90.4% of ECNO < -13.0dB).
DRIVE TEST RESULT
• UE_TX POWER DISTRIBUTION

• 98.2% UL is below 10dBm which shows that UE is transmitting power in a control manner with reduced UL
Interference, and also those sites are serving in the intended areas.
DRIVE TEST RESULT
• Call Drop and Setup Failure Analysis Breakdown:

Call Information Overview (CS Domain)


Call Analysis
Call Setup Failure Rate 2.6% Number of Calls 115

Call Drop Rate 0.0%


Overall Call Success Rate (End to End) 97.4%

100.0%
90.0%
80.0%
70.0%
60.0%
50.0%
40.0%
30.0%
20.0%
10.0%
0.0%
Call Setup Failure Call Drop Rate Overall Call Success
Rate Rate (End to End)
DRIVE TEST RESULT
• Call Setup status:
Call Setup Status
- The table and graph below show the breakdown of all calls if they succeeded or if they failed.
It also shows the reasons why the call failed

A Call Setup Failure during RRC Connection Setup Phase 0 #N/A


B Call Setup Failure during Access Phase due to RACH/FACH 2 2
C Call Setup Failure due to RRC Connection Reject 0 #N/A
D Call Setup Failure during Security Procedure 1 1
E Call Setup Failure during RAB Setup procedure 0 #N/A
F Call Setup Success 112 112

2% 1%
Call Setup Status

A Call Setup Failure during RRC Connection Setup Phase

B Call Setup Failure during Access Phase due to RACH/FACH

C Call Setup Failure due to RRC Connection Reject

D Call Setup Failure during Security Procedure

E Call Setup Failure during RAB Setup procedure

F Call Setup Success

97%
INTRODUCTION

Drive Test Result

Analysis

CONCLUTION & RECOMMENDATION


POOR COVERAGE ANALYSIS 1

Problem: Poor coverage


Cause: bad landscape , The main road covered by
huge trees.
Solution:- UP tilt by 2 degree of sites 244546
sector C and Up tilt 244006 sector A by 2 degree.
POOR COVERAGE ANALYSIS 2

Problem: Poor coverage


Cause: Physical antenna tilt.
Solution:- UP tilt by 2 degree of sites 244546 sector C and shift the
azimuth of U4546 Sector C by 30 Degree(240 to 270).
POOR COVERAGE ANALYSIS 3

Problem: Poor Coverage


Cause: Too many server on the area.
Solution:- UP tilt ET of 244006 sec A by 2 degree and Down
tilt ET of 244008 & 244009 sec B by 2 degree.
POOR COVERAGE ANALYSIS 4

Problem: Poor Coverage Problem: Poor Coverage


Cause: lack of dominant cell. Cause: lack of dominant cell.
Solution:-UP Tilt the ET of 244007 Solution:-UP Tilt the ET of 244006
sec B by 2 degree.(7 to 5) sec B by 2 degree.(8 to 6)
POOR COVERAGE ANALYSIS 5

Problem: Poor Coverage


Cause: Too many server on the area and lack of dominant cell.
Solution:- Down tilt by 2 degree the following sites, 244008 sec
B ,244009 sec B, Up tilt 244011 sec B by 2 degree.
POOR COVERAGE ANALYSIS 6

Problem: Poor Coverage


Cause: Too many server on the area and lack of dominant cell.
Solution:- Down tilt ET 244008 Sec A by 2 degree(4 to 6) and Up
tilt ET by 2 degree 244011 Sec A (8 to 6).
POOR EcNo ANALYSIS 1

Problem: Poor Quality


Cause: Too many server on the area and overshooting site.
Solution:- Down tilt the following sites 244008 Sec A,244009 Sec A and 244011 Sec C.
Call Setup Failure Analysis Breakdown.
Problem : call setup failure.
Cause : bad coverage.
solution : UP tilt by 2 degree of
sites 244546 sector C and Up tilt
244006 sector A by 2 degree.
OSS analysis
Site ID Availability% CSSR_Speech CDR_Speech RRC_Cong% RAB_Cong%
244006 97.637 99.665 1.098 0.141 0.457
244007 93.534 99.838 0.717 0.080 1.923
244008 92.324 99.616 0.712 0.225 1.643
244009 74.172 99.856 0.471 0.065 0.818
244010_ 99.976 99.895 0.515 0.044 0.372
244011_ 99.847 99.878 0.538 0.089 1.347
244012_ 99.970 99.908 0.380 0.053 0.890
244014 99.981 99.461 0.915 0.522 0.821
244015_ 99.957 99.915 0.467 0.056 1.303
244016_ 99.893 99.893 0.495 0.047 1.094
244017 93.610 98.142 0.964 0.978 4.245
244546 99.893 99.751 0.974 0.188 0.821
Grand Total 95.899 99.652 0.687 0.207 1.311

-Observation-from the above oss data the site performance of all site in agaro cluster is good but the availability of
244007,244008 and 244009 need is not good, we escalate the power team to reverse this situation.
INTRODUCTION

Drive Test Result

Analysis

CONCLUTION & RECOMMENDATION


CONCLUSION AND RECOMMENDATION

Conclusion
• From Agaro city Pre Drive Test result , we can see there is poor coverage((>-95dbm (89.3%)) and quality(>-
13dB (90.4%)).
• Have 3 Call setup failure and no call drop.
Recommendation
• Implementation of given analysis(FN-5) it gives good improve on Downlink coverage and
quality for
Agaro city.
• To eliminate call setup failure ,we should be change poor coverage to good coverage.
• Reduce the overshooting site by down tilt electrical tilt of the following sites, 244007 Sec A, 244008 Sec
A,244009 Sec A,244011 Sec C.
• The site performance of agaro site good but the availability of the following site 244007,244008 and
244009 need investigation so we escalate the power team.
THANK YOU