Professional Documents
Culture Documents
Common Trouble-Shooting Method of Road Roller
Common Trouble-Shooting Method of Road Roller
check whether
(3) Check whether the emergency stop
button is reset
connection of operation device after faulty
operation
with main pump’s manual
servo valve is reliable; check
whether emergency stop
button is reset after faulty
operation (shown in Fig.1) Fig.1
Fig.2
Exchange
relief valve
for trouble
shooting
Fig.4 Fig. 5
Fig.6
(3) Press the button, that indication of the indicator of the PLC is
normal, which means this branch of the circuit is normal, then
check whether the connecting wire between driver with stepping
motor is normal.
Stepping
(4) Press the button, stepping motor
First teach the client how to remove the reducer and disassembly it
according to the process.
(1) Remove all the bolt of outer case, take apart rotary part with fixing part. Shown in
below figure.
dismantle
rotary part
of reducer
(2) Take away snap rings of 4 planet gear by snap ring plier. Shown in below figure.
dismantle fixing part of
reducer.
(5) Remove the big lock nut below the planet gear, it maybe too tighten
to remove, that hit it for some times by hammer will loose the nut.
Shown in below figure.
(6) Take out the snap ring and brake block. Shown in below figure.
(7) Finally, pry the edge by big screw driver, and we can take apart it
completely so that the inner float seal ring can be seen.
Gas spring
Anti-freeze
liquid
check thermostat and
observation
the tension of belt.
windows
Monoblock pump
First turn key switch to on position, and listen whether there is ‘tick tack’
when solenoid is engaged, or take out the solenoid, and check whether shift
fork of solenoid works in normal condition when energized. Check battery
observing spot, if it is black, requires charging, which means battery is
normal, after that, it shows the flameout solenoid is in good condition.
(1) Check energization condition of flameout solenoid, and it is found that
flameout solenoid is still energized and in throttle-open position after turn off
the power supply by key switch. And it is found the power is from generator
after checking.
There is clamping
stagnation between
flameout solenoid
and rack.
Thank you!