1 Maintenance of suspended dry powder fire


extinguishing device
悬挂式干粉灭火装置 产品介绍

Manual start of fire extinguisher and status judgment of


alarm switch indicator light

Fire extinguishing device meter start alarm


feedback switch indication status judgment
The green light is on After the power is turned
on, the green light is always on, indicating that
the system is working normally;

The yellow light is on, and the buzzer


alarms intermittently, indicating that the
starting wiring harness of the fire
extinguishing device is not connected or
the starting wiring harness is connected
incorrectly, grounding, etc.;
悬挂式干粉灭火装置 产品介绍

Manual start of fire extinguisher and status judgment of


alarm switch indicator light

Fire extinguishing device meter start alarm


feedback switch indication status judgment

The red light is on and the buzzer


beeps for a long time, indicating that
the suspended dry powder fire
extinguishing device is activated.

When using the start feedback alarm


switch to start the fire extinguishing
fire
exting device, open the upper cover, crush
uisher the red button cover, hold for 1-2
seconds, and then start the hanging
dry powder fire extinguishing device
to extinguish the fire.
悬挂式干粉灭火装置 产品介绍

Product Maintenance
1 、 The fire extinguishing device should be inspected
regularly, and the annual inspection items:
★ The validity period of the fire extinguishing agent is 5
years; after the validity period of use, it shall not be
disassembled and disposed of by itself.
★When replacing the fire extinguishing device, the non-
electric self-starting device arranged on the device must be
replaced at the same time;
悬挂式干粉灭火装置 产品介绍

Product Maintenance

2 、 The fire extinguishing device should be inspected


regularly, and the monthly inspection items:
●Check that the fire extinguishing device should be installed
securely and should not be loose or fall off;
●Check that the parts connected to the fire extinguishing
device should not be loose or fall off;
●Check whether the line connection of the fire extinguishing
device is normal, there should be no open circuit or short circuit
(no live maintenance);
●Check that the appearance of the fire extinguishing device
and its accessories should be clean and there should be no
excess oil residue;
悬挂式干粉灭火装置 产品介绍

Product Maintenance
3 、 Fire extinguishing equipment should be checked
regularly, and items should be checked daily :
● Before leaving the car every day, check the light
status of the fire extinguisher switch on the dashboard,
the green light is always on, and the yellow light is
faulty!
悬挂式干粉灭火装置 产品介绍

Inspection and maintenance precautions


2 、 Check whether the fixing
bolts of the fire extinguishing
device are loose, falling off or
missing. If the fixing bolts and
mounting brackets of the fire
extinguishing device are loose,
the device and the mounting
brackets should be fastened in
time.
1 、 Check the appearance of the
fire extinguishing device for
cracks, deformation, large-area
paint loss, rust and other
undesirable phenomena. If the
device has the above conditions,
the fire extinguishing device
should be replaced in time to
ensure the effectiveness of the
device 。
悬挂式干粉灭火装置 产品介绍

Inspection and maintenance 4 、 Check whether the connector of the fire


extinguishing device is firmly connected with the quick
precautions connector. If the connector is loose, the connector
should be inserted into the quick connection to check
whether the connecting wires of the fire extinguishing
device are damaged, broken, the end of the self-
starting device without electricity is split, soaked in
water, etc. If it is damaged or broken, it should be
replaced in time Wire harness, if the end of the self-
starting device without electricity is split, soaked in
water, etc., the end of the thermal wire should be
reduced until there is no split or water stains.

3 、 Check whether the


connection between the thermal
line, the fire extinguishing device
and the quick connector is loose.
If there is looseness, reinforce or
replace the fire extinguishing
device and accessories.
悬挂式干粉灭火装置 产品介绍

Inspection and maintenance precautions


6 、 Check whether the
connection between the
connector of the fire extinguishing
device and the start alarm switch
and the wiring harness of the
body is loose.

5 、 Check whether the manual start


alarm switch of the fire extinguishing
device is in normal working
condition (the green light is always
on). (The red light means the device
has been started, and the yellow
light means the fault).
悬挂式干粉灭火装置 产品介绍
Inspection and maintenance 8 、 Check whether the end of the non-
precautions electric self-starting device is covered by
oil, dust, etc., and whether the wire harness
fixing tie is broken. If it is covered by oil or
dust, the covered part should be cut off. To
avoid the non-electric self-starting device
falling down due to the breakage of the
cable tie, and contacting the high-
temperature parts, which will cause the
device to start by mistake.

7 、 Check whether the emergency


start button of the start switch has
been broken. If the start button has
been broken, replace the start
button in time and check whether
the fire extinguishing device has
been started;