CMT / CMT MIX CORRECTION & PARAMETER SETTING

1. CMT Correction parameter


a. CMT Arc length correction
b. CMT Dynamic correction

2. CMT Mix Corrections & Parameter Setting


a. CMT Mix High Power Time Correction
b. CMT Mix Low Power Time Correction
c. CMT Mix Low Power Correction
d. CMT Mix Application of Power Correction and Power Time Correction
e. CMT Mix Arc length correction
f. CMT Mix Pulse correction

2
Fronius International GmbH / Höglinger Stefan / CMT / CMT mix Einstellparameter / 07.11.2016
CMT Correction
Parameter

3
Fronius International GmbH / Höglinger Stefan / CMT / CMT mix Einstellparameter / 07.11.2016
1. CMT CORRECTION PARAMETER

CMT process parameter

The correction of the arc-length and the arc-


dynamic at the CMT process is generated by an
adjustment of the wire feed speed and the
welding current profile.

4
Fronius International GmbH / Höglinger Stefan / CMT / CMT mix Einstellparameter / 07.11.2016
1a. CMT ARC LENGTH CORRECTION

Arc length correction


The length of the arc in the arc burning period is adjusted
by the time of the backward and forward movement. This
wire speed corrections in length and height are specific for
synergic line.

Unit -
Range -10 to + 10
Default 0

Application of the arc length correction


Positive correction causes a longer backward movement
period and a reduced forward feeding speed for the wire
electrode, what results in an extension of the arc within the
CMT process period.

Negative correction gives a shorter arc length by


reducing the time of the backward movement and
increasing the amount of the forward feeding speed of the
wire electrode.

5
Fronius International GmbH / Höglinger Stefan / CMT / CMT mix Einstellparameter / 07.11.2016
1a. CMT ARC LENGTH CORRECTION

6
Fronius International GmbH / Höglinger Stefan / CMT / CMT mix Einstellparameter / 07.11.2016
1b. CMT DYNAMIC CORRECTION
Dynamic Correction
This correction represents the dynamic or short-circuit behavior of
the CMT drop transfer. The current-level at the point of reigniting in
a CMT period and the acceleration ramp of the wire feeder after the
point when the short circuit occurs, are adjusted with this
correction.

Unit -
Range -10 to + 10
Default 0

Application of the dynamic correction

The negative correction rises the current level at the point of


reigniting in a period and increases the acceleration ramp of the
wire feed speed. As a result the drop transfer time is shortened, the
process frequency is increased and CMT feels to be more intense.

The positive correction lowers the current level at reigniting and


gives a reduced acceleration ramp for the wire feeder. This results
in a longer duration of the drop transfer, the process frequency is
lowered and CMT feels to be smoother.

7
Fronius International GmbH / Höglinger Stefan / CMT / CMT mix Einstellparameter / 07.11.2016
1b. CMT DYNAMIC CORRECTION

8
Fronius International GmbH / Höglinger Stefan / CMT / CMT mix Einstellparameter / 07.11.2016
1b. CMT DYNAMIC CORRECTION HEAT INPUT CONTROL

9
Fronius International GmbH / Höglinger Stefan / CMT / CMT mix Einstellparameter / 07.11.2016
CMT Mix Correction &
Parameter setting

10
Fronius International GmbH / Höglinger Stefan / CMT / CMT mix Einstellparameter / 07.11.2016
2. CMT MIX CORRECTION & PARAMETER SETTING

CMT Mix adjustment

„CMT Mix“ is a combination of CMT and PMC cycles in one welding process. Hot PMC process
periods are followed by cold CMT process periods.

The “high power time” and “low power time” -correction determines the ration between the hot-
and cold- process phase. Primarily the “arc length” and “pulse dynamic” can be adjusted. The
usage, as well as all correction parameters are explained below:

11
Fronius International GmbH / Höglinger Stefan / CMT / CMT mix Einstellparameter / 07.11.2016
2. CMT MIX

12
Fronius International GmbH / Höglinger Stefan / CMT / CMT mix Einstellparameter / 07.11.2016
2a. CMT MIX HIGH POWER TIME CORRECTION

High power time correction


The duration of the hot PMC period is adjusted.

Unit -
Range -10 to + 10
Default 0

13
Fronius International GmbH / Höglinger Stefan / CMT / CMT mix Einstellparameter / 07.11.2016
2a. CMT MIX HIGH POWER TIME CORRECTION

14
Fronius International GmbH / Höglinger Stefan / CMT / CMT mix Einstellparameter / 07.11.2016
2b. CMT MIX LOW POWER TIME CORRECTION

Low power time correction


The number of the cold CMT cycles is adjusted.

Unit -
Range 1 to 100
Default 1

15
Fronius International GmbH / Höglinger Stefan / CMT / CMT mix Einstellparameter / 07.11.2016
2b. CMT MIX LOW POWER TIME CORRECTION

16
Fronius International GmbH / Höglinger Stefan / CMT / CMT mix Einstellparameter / 07.11.2016
2c. CMT MIX LOW POWER CORRECTION

Low power correction


The energy input (wire feed speed) in the cold CMT period is adjusted.

Unit -
Range -10 to + 10
Default 0

17
Fronius International GmbH / Höglinger Stefan / CMT / CMT mix Einstellparameter / 07.11.2016
2d. CMT MIX APPLICATION POWER
CORRECTION & POWER TIME CORRECTIONS

Application of the power corrections


Rising the „high power time correction“ causes a reduction of the process frequency due to an
extension of the PMC process period.

Reduction of the „high power time correction“ rises the process frequency with an reduction of
the PMC process period.

The same applies to the CMT process period with the “low power time correction”.

Rising the “low power correction” gives a higher wire feed speed (wire deposition) and
therefore a higher welding current in the cold CMT process period.

18
Fronius International GmbH / Höglinger Stefan / CMT / CMT mix Einstellparameter / 07.11.2016
2e. CMT MIX ARC LENGTH CORRECTION
Arc length correction with PMC Mix process

Similar to all FRONIUS welding processes, the mean value of the welding voltage is adjusted with the arc length correction.

Unit -
Range -10 to + 10
Default 0

Application of the arc length correction

A positive correction increases the welding voltage during the PMC period and gives a longer reversing time during the CMT period, which results in a reduction
of the arc length.

A negative correction lowers the welding voltage during the PMC period and gives a shorter reversing time during the CMT period, which results in an elongation
of the arc.

19
Fronius International GmbH / Höglinger Stefan / CMT / CMT mix Einstellparameter / 07.11.2016
2f. CMT MIX PULSE CORRECTION
Pulse correction with CMT Mix process

The energy in the impulse process period of the PMC welding process is adjusted. The amount of energy or area below the pulses keep almost the same
area.

Unit -
Range -10 to + 10
Default 0

Application of the pulse correction

A positive correction enlarges the energy with an enlarged current level and width of the pulses, a reduced pulse-frequency during the PMC Period is the result.

A negative correction lowers the energy, current level and width of the pulse, a higher pulse-frequency during the PMC Period is the result.

20
Fronius International GmbH / Höglinger Stefan / CMT / CMT mix Einstellparameter / 07.11.2016
All information is without guarantee in spite of careful editing - liability excluded.
Intellectual property and copyright: all rights reserved. Copyright law and other laws protecting intellectual property apply to the content of this presentation and the documentation enclosed (including texts, pictures, graphics, animations
etc.) unless expressly indicated otherwise. It is not permitted to use, copy or alter the content of this presentation for private or commercial purposes without explicit consent of Fronius.

You might also like