Professional Documents
Culture Documents
Expert CMT CMT Mix Correction and Parameter Setting EN
Expert CMT CMT Mix Correction and Parameter Setting EN
2
Fronius International GmbH / Höglinger Stefan / CMT / CMT mix Einstellparameter / 07.11.2016
CMT Correction
Parameter
3
Fronius International GmbH / Höglinger Stefan / CMT / CMT mix Einstellparameter / 07.11.2016
1. CMT CORRECTION PARAMETER
4
Fronius International GmbH / Höglinger Stefan / CMT / CMT mix Einstellparameter / 07.11.2016
1a. CMT ARC LENGTH CORRECTION
Unit -
Range -10 to + 10
Default 0
5
Fronius International GmbH / Höglinger Stefan / CMT / CMT mix Einstellparameter / 07.11.2016
1a. CMT ARC LENGTH CORRECTION
6
Fronius International GmbH / Höglinger Stefan / CMT / CMT mix Einstellparameter / 07.11.2016
1b. CMT DYNAMIC CORRECTION
Dynamic Correction
This correction represents the dynamic or short-circuit behavior of
the CMT drop transfer. The current-level at the point of reigniting in
a CMT period and the acceleration ramp of the wire feeder after the
point when the short circuit occurs, are adjusted with this
correction.
Unit -
Range -10 to + 10
Default 0
7
Fronius International GmbH / Höglinger Stefan / CMT / CMT mix Einstellparameter / 07.11.2016
1b. CMT DYNAMIC CORRECTION
8
Fronius International GmbH / Höglinger Stefan / CMT / CMT mix Einstellparameter / 07.11.2016
1b. CMT DYNAMIC CORRECTION HEAT INPUT CONTROL
9
Fronius International GmbH / Höglinger Stefan / CMT / CMT mix Einstellparameter / 07.11.2016
CMT Mix Correction &
Parameter setting
10
Fronius International GmbH / Höglinger Stefan / CMT / CMT mix Einstellparameter / 07.11.2016
2. CMT MIX CORRECTION & PARAMETER SETTING
„CMT Mix“ is a combination of CMT and PMC cycles in one welding process. Hot PMC process
periods are followed by cold CMT process periods.
The “high power time” and “low power time” -correction determines the ration between the hot-
and cold- process phase. Primarily the “arc length” and “pulse dynamic” can be adjusted. The
usage, as well as all correction parameters are explained below:
11
Fronius International GmbH / Höglinger Stefan / CMT / CMT mix Einstellparameter / 07.11.2016
2. CMT MIX
12
Fronius International GmbH / Höglinger Stefan / CMT / CMT mix Einstellparameter / 07.11.2016
2a. CMT MIX HIGH POWER TIME CORRECTION
Unit -
Range -10 to + 10
Default 0
13
Fronius International GmbH / Höglinger Stefan / CMT / CMT mix Einstellparameter / 07.11.2016
2a. CMT MIX HIGH POWER TIME CORRECTION
14
Fronius International GmbH / Höglinger Stefan / CMT / CMT mix Einstellparameter / 07.11.2016
2b. CMT MIX LOW POWER TIME CORRECTION
Unit -
Range 1 to 100
Default 1
15
Fronius International GmbH / Höglinger Stefan / CMT / CMT mix Einstellparameter / 07.11.2016
2b. CMT MIX LOW POWER TIME CORRECTION
16
Fronius International GmbH / Höglinger Stefan / CMT / CMT mix Einstellparameter / 07.11.2016
2c. CMT MIX LOW POWER CORRECTION
Unit -
Range -10 to + 10
Default 0
17
Fronius International GmbH / Höglinger Stefan / CMT / CMT mix Einstellparameter / 07.11.2016
2d. CMT MIX APPLICATION POWER
CORRECTION & POWER TIME CORRECTIONS
Reduction of the „high power time correction“ rises the process frequency with an reduction of
the PMC process period.
The same applies to the CMT process period with the “low power time correction”.
Rising the “low power correction” gives a higher wire feed speed (wire deposition) and
therefore a higher welding current in the cold CMT process period.
18
Fronius International GmbH / Höglinger Stefan / CMT / CMT mix Einstellparameter / 07.11.2016
2e. CMT MIX ARC LENGTH CORRECTION
Arc length correction with PMC Mix process
Similar to all FRONIUS welding processes, the mean value of the welding voltage is adjusted with the arc length correction.
Unit -
Range -10 to + 10
Default 0
A positive correction increases the welding voltage during the PMC period and gives a longer reversing time during the CMT period, which results in a reduction
of the arc length.
A negative correction lowers the welding voltage during the PMC period and gives a shorter reversing time during the CMT period, which results in an elongation
of the arc.
19
Fronius International GmbH / Höglinger Stefan / CMT / CMT mix Einstellparameter / 07.11.2016
2f. CMT MIX PULSE CORRECTION
Pulse correction with CMT Mix process
The energy in the impulse process period of the PMC welding process is adjusted. The amount of energy or area below the pulses keep almost the same
area.
Unit -
Range -10 to + 10
Default 0
A positive correction enlarges the energy with an enlarged current level and width of the pulses, a reduced pulse-frequency during the PMC Period is the result.
A negative correction lowers the energy, current level and width of the pulse, a higher pulse-frequency during the PMC Period is the result.
20
Fronius International GmbH / Höglinger Stefan / CMT / CMT mix Einstellparameter / 07.11.2016
All information is without guarantee in spite of careful editing - liability excluded.
Intellectual property and copyright: all rights reserved. Copyright law and other laws protecting intellectual property apply to the content of this presentation and the documentation enclosed (including texts, pictures, graphics, animations
etc.) unless expressly indicated otherwise. It is not permitted to use, copy or alter the content of this presentation for private or commercial purposes without explicit consent of Fronius.