Summary of Design Problem:

P r e s e n t e d b y : J a s p e r A n g e l e s L l a n e r a
Summary of Design
Problem:

The local government of a city with a population of 200,000 is


planning to relocate its government center due to space
constraints. They have acquired a ten-hectare lot and a four-hectare
lot next to the sea for the new complex. In addition to government
facilities, the project includes a modern sports center, playground,
garbage incinerator, public market, bus terminal, and abattoir. The
city is situated by a bay with fertile agricultural lands, good fishing
grounds, and beaches, making tourism a priority. However,
pollution and squatting are issues along a 30-meter wide river
running through the city. The design will also include developing
driveways and promenades along the riverbanks.
DESIGN CONCEPT
NEO CLASSICAL FILIPINO ARCHITECTURE REFERS
TO A STYLE THAT EMERGED IN THE PHILIPPINES

. DURING THE 19TH AND EARLY 20TH CENTURY.


THE STYLE IS CHARACTERIZED BY SYMMETRICAL
FACADES, COLUMNS, PEDIMENTS AND OTHER
CLASSICAL ELEMENTS. INCORPORATING NEO
CLASSICAL FILIPINO ARCHITECTURE OFTEN
SIGNIGIES POWER, AUTHORITY, AND SENSE OF
GRANDEUR REFLECTING COUNTRY’S COLONIAL
HISTORY.

SITE ANALYSIS
THE SITE IS LOCATED NEAR THE SOUTCH CHINA
SEA AND HAS A 30 METER RIVER ON THE
. ADJACENT ROAD.
THE NORTHINGS IS POINTED TOWARDS
NORTHEAST
THERE ARE 3 ACCESS TO ROAD
BAHAY KUBO
FORM CONCEPT CHARACTERIZED BY ITS STEEP THATCHED ROOF AND
OPEN FLOOR PLAN. THE VERNACULAR ARCHITECTURE
REFLECTS TGE FILIPINO CULTURE VALUES OF
COMMUNITY ADDITIONALLY TO THE TROPICAL
CLIMATE AND HARMONY TO NATURE. IN THE DESIGN
OF THE PROJECT THE USE OF HIGH PITCH OF HIP
ROOF AND MODULARITY IN PLANNING WAS
INCORPORATED IN THE DESIGN.
MATERIALS
Concrete

a composite material composed of


aggregate bonded together with a
fluid cement that cures over time.
PRE COATED
ALUMINUM SHEET
designed to provide a rugged, abrasive resistant coating and enhanced flexibility for
extensive forming and fabricating. High-quality pre-painted aluminum sheet also offers
excellent corrosion resistance, formability, and welding characteristics.
ALUMINUM STEEL

steel that has been plated with


aluminium or aluminium-silicon alloy,
in a process analogous to hot-dip
. galvanizing. The steel workpiece is
immersed in molten aluminum to
produce a tight metallic bond between
the steel and coating.
DESIGN INNOVATION

TACTILE PAVEMENT PERMEABLE PAVEMENT


a system of textured indicators on the ground’s surface connected spaces that allow water to percolate through
that can be felt underfoot or by cane. Tactile paving with the surface.
an attention pattern has a series of truncated domes
forming a grid pattern.

VENTINILLA CLERESTORY WINDOW


an opening in a wall, floor, ship’s deck any fenestrated (windowed) wall of a room that is carried
higher than the surrounding roofs to light the interior
space.
LOCAL CODES
LAW OF ENHANCE MOBILITY OF DISABLED PERSONS (BP 344)
• HANDRAILS SHOULD BE INSTALLED AT THE BOTH SIDES
OF RAMPS AND STAIRS.
• PATHWAYS – PROVIDING PATHWALK FOR PEOPLE
ESPECIALLY FOR THE BLIND PARKING AREAS – MINIMUM
OF 3.70M AND 1.20 CLEAR WIDTH ACCESSIBLE
• WATERCLOSET - IS 1.70 MX 1.80M
• RAMPS – GRADIENT SHALL BE 1:12 AND LENGTH SHOULD
NOT EXCEED 6M ALSO PROVIDE LANDING NOT LESS THAN
1.50M
• ELEVATOR – MINUM OF 1.1 M X 1.40 M
PARKING
• LOCAL GOVERNMENT COMPLEX - 1 CAR SLOT AND 1
JEEPNEY SLOT ARE ALLOCATED FOR EVERY 50 SQM
SPECTATOR AREA AND 1 BUS SLOT ALLOCATED FOR
EVERY 200 SPECTATOR

• PUBLIC ASSEMBLY – 1 CAR SLOT & 1 JEEPNEY SLOT/ 50


SQM OF SPECTATOR AREA PUBLIC MARKET – 1 CUSTOMER
PARKING SLOT/ 150 SQM, 1 VENDOR PARKING SLOT/300
SQM.

• TERMINALS -1 CAR SLOT PER 500 SQM OF GROSS FLOOR


AREA AND ONE 1 OFF RROW . 2 QUEUED JEEPNEY SLOTS
FIRE CODE OF THE PHILIPPINES
• SPRINKLER SYSTEM – AUTOMATIC SPRINKLER SHALL BE
INSTALLED IN ACCORDANCE TO SECTION 10.2.6.7
BUILDINGS GREATER THAN (1,115MSQM)

• PORTABLE EXTINGUISHER – FOR WORK BUILDINGS AND


SHALL BE LOCATED 23M DISTANCE EXIT ARRANGEMENT -
Exits shall be so arranged that at least two (2) separate exits will be
available from every floor area
BUILDING HEIGHT LIMIT

• LOCAL GOVERNMENT COMPLEX – 15 METERS BHL

• SPORTS COMPLEX – 25M BHL PUBLIC MARKET – 18M BHL

• TERMINALS – 15 M BHL ABBAITOR – 21M BHL


LIGHTS AND VENTILLATION
TABLE VIII.3. SETBACK

• COMMERCIAL – WITH 20 M RROW ( 5M FRONT, 3M BOTH


SIDES AND REAR)

• INSTITUTIONAL – WITH 20 M AND 30 M RROW ( 5-6 M


FRONT, 3M BOTH SIDES AND REAR)
EXTERIOR PERSPECTIVE
-
MUNICIPAL HALL
REFERENCES

https://www.meteoblue.com/en/weather/historyclimate/climatemodelled/lingayen_
philippines_1706188
lingayen-binmaley_288_l.m._plan.pdf NATIOANAL BUILDING CODE OF THE
PHILLPINES RA9266 FIRE CODE OF THE PHILIPPINES OF 2008 RA9514
PLUMBING CODE OF THE PHILIPPINES