Download as pptx, pdf, or txt
Download as pptx, pdf, or txt
You are on page 1of 18

NEW AIR-COOLED SCROLL CHILLER CGAF

260 – 700 kW

CXAF Air cooled Scroll Heat Pump


Coming Soon
Trane’s Sintesis™ air-cooled chiller portfolio represents industry leading
performance and flexibility– for a perfect fit not only to your building and
application requirements, but also to your sustainability and budget targets.
The Sintesis™ Advantage model CGAF belongs to the Trane Sintesis™
air-cooled chiller portfolio representing industry leading performance
and flexibility – for a perfect fit not only to your building and application
requirements, but also to your sustainability and budget targets.
BENEFITS
Market leader Sintesis™ platform, multiple technologies available

• Fast lead time, easy maintenance and service

Remarkable performance, optimized for part loads

• 3 efficiency levels and 3 acoustic packages

Wide capacity range, cost-effective solutions, small footprints

• No compromise, flexible offer to better meet customer needs


PRODUCT LINEUP
Wide offer in terms of capacity, efficiency and acoustic
Cooling/heating capacity kW
250 270 290 310 330 350 370 390 410 430 450 470 490 510 530 550 570 590 610 630 650 670 690 700
Product Line Up
TRANE SE
CGAF HE
XE

Cooling capacity 3 Efficiency level 3 Acoustic level Energy saving solutions


• 170 – 700 kW • Standard efficiency • Standard noise • EC fans
• 14 sizes • High efficiency • Low noise • Free cooling
• Extra high efficiency • Extra low noise • Total heat recovery
• Partial heat recovery
EER up to 3.41 Night noise set back for
extra silent operation
ESEER up to 4.74
MAIN FEATURES
Brazed plate heat
AC Fans exchanger
EC Fans
Redesigned
fan diffuser

Free Cooling

Micro-channel
condenser coil

Scroll
Compressors

…And more!
Total and partial
Heat recovery
5388487919
Buffer Tank Soft Starter

Hydraulic UC800
Freeze Protection
module TD7
FOOTPRINT
Compact design and layout: 22% smaller compared to
Trane legacy products

“V” shaped coils

6 Frames layout: from 2V to 6V

Integrated Hydraulic module


• Single or dual pump kit
MICRO-CHANNEL CONDENSER COIL
Excellent heat transfer and a greater corrosion resistance
versus conventional tubes in fins coils

100% aluminum

Longer life expectancy

Increased efficiency with less refrigerant

Reduced carbon footprint

10% overall unit weight reduction


ELECTRONICALLY COMMUTATED (EC) FANS
EC fans are the perfect option to reduce power consumption at part load,
allowing also a significant reduction of sound level

Improved capacity modulation

Reduced power consumption and energy costs

Better operation at low ambient conditions


PERFORMANCES
Premium efficiencies: remarkable performances

Standard efficiency
• EER up to 3.04
• ESEER up to 4.13
High efficiency
• EER up to 3.27
• ESEER up to 4.16
Extra high efficiency
• EER up to 3.41
• ESEER up to 4.74

All units will be compliant with Ecodesign regulation 2018


Energy saving Free cooling solutions
• EC fan motors (optional)
• Optimized fan diffusor
PERFORMANCES
Top class part load efficiencies: 5% more efficient at part load compared
to the benchmark
ACOUSTICS
Soundproof operation: extra low noise emission
Standard noise: SN
from 92 to 97 dB(A)
Low noise: LN
from 89 to 94 dB(A)
 Compressor jacket
Extra low noise: XLN
• from 87 to 91 dB(A)
Piping insulation
Compressor sound box

Night noise setback available


ACOUSTICS
For even greater acoustic comfort…
Silent mode with Night Noise Setback Industry-leading fan diffusor

• Thanks to the Night Noise Set Back it is • EC fans can be equipped with a special
possible to set an extra silenced operation diffuser to provide a quieter operation and
profile air flow optimization

• The sound level of the chiller is reduced by • Efficiency is boosted by converting


decreasing the speed of EC fans, controlled dynamic airflow into static pressure
with an external on/off contact allowing a fan speed reduction, with the
effect of lower acoustic pressure and
• This option is designed for night operation,
energy consumption with unchanged
allowing perfect acoustic comfort at night time
airflow
without compromising the efficiency during
times of greater load
ENERGY SAVING SOLUTION
Reduce energy costs by taking advantage of favorable outdoor
temperatures or converting the energy produced the during cooling cycle

Heat recovery Free cooling


• Heat recovery system re-uses the • Designed for applications that requires cooling
all year round
waste heat generated during the
cooling cycle, instead of exhausting
it to the atmosphere
• It is possible to choose between
two different level of heat recovery

Total heat recovery


• When THR mode is ON, the
chiller can produce heating up
to 100% of the cooling capacity
Partial heat recovery
• When PHR mode is ON, the
chiller can produce heating up
to 25% of the cooling capacity
OPERATING MAP
Extended operating limits for process and comfort application: CGAF is designed
for all year-round operation over a wide range of ambient temperatures
Standard ambient:
• -10°C to +46°C

Low ambient:
• -20°C to +46°C
High ambient:
• -10°C to +52°C
Wide ambient:
• -20°C to +52°C
PRODUCT CONFIGURATION
Flexible and versatile product configuration and selection: Multiple
bundles to choose from, always the right product for every application!
CONTROLS
Simple and intuitive user interface

Controller Trane Tracer UC800 User interface with front panel TD7
• Advanced algorithms to manage • Large touch screen
the most challenging conditions
• Full-color interface for simple, intuitive
• Ease of maintenance and service operation
• Modular bus architecture to cover • Main processor in the control panel
product range

You might also like