A PRESENTATION

ON

Extra high voltage (EHV)


Session: - 2023

DEPARTMENT OF ELECTRICAL AND


ELECTRONICS ENGINEERING

GALGOTIA’S COLLEGE OF ENGINEERING &TECHNOLOGY


GREATER NOIDA -201310

Presented to :-
Presented by:- :-
TABLE OF CONTENTS
INTRODUCTION
GENERAL DISCUSSION ON SUBSTATION
 POWER TRANSFORMER
 SWITCHGEAR(SWG)
 WORKSHOP

 RING MAIN UNIT (RMU)


 COMPONENTS OF RMU
 TESTING OF RMU

 AIR CIRCUIT BREAKER


 COMPONENTS OF ACB

 TYPES OF CIRCUIT BREAKER


 PROTECTIVE RELAYS & ITS TYPES
INTRODUCTION
 BSES stands for "Bombay Suburban Electric Supply" which is
the part of Reliance Infrastructure Limited .

 Divided into Two parts:-


(i) BSES Rajdhani Power Limited (BRPL)
(ii) BSES Yamuna Power Limited (BYPL)

 BSES Yamuna Power Limited (BYPL) is a joint venture between


the Government of Delhi and Reliance Infrastructure Limited,
which holds a 51% majority stake in the venture.

 BYPL is engaged in power distribution in areas of Eastern and


Central Delhi while BRPL distributes electricity in South Delhi
and West Delhi areas
SUBSTATION
Receives power at 220kV
Transmission of Electricity
Distribution of Electricity
High Voltage is stepdown
to Low voltage using PTR

Ex.-
 220kV/66kV substation
 66kV/33kV substation
 66kV/11kV substation
 33kV/11kV substation
66KV Kamla market substation
 It is divided into two parts:-
A. Panel Section
 Control Panel Section
 Relay and Protection Panel Section

B. Switch Yard
 66kV Section
 33kV section
A. Panel Section
 It is a room which contains all types of panels.
 It has two sections:-
 Control Panel Section
It contain panels related to controlling of instruments.
E.g.:- feeder panel, transformer panel, Scada control
panel etc.

 Relay And Protection Panel Section


It contains panels related to relay systems and
protection systems. E.g.:- Switchgear (SWG), line
protection panel, etc.
B. Switch Yard
 It is the field where components are used in controlling

and measuring supply.


 Some of these components are:-
 Switchgear (SWG)
 Power Transformers etc.
power distribution from
substation to consumers
POWER TRANSFORMER

 A electrical Device.
Transfer electrical energy
between two or more circuits
through electromagnetic
induction
No Change in Frequency.
SWITCHGEAR (swg)
Switchgear is a combination
of electrical devices, such as
switches, circuit breakers,
fuses, CT, PT and relays etc.

Improving overall system


efficiency & quickly operated
through SCADA.

 It’s main function is to


control, protect, and isolate
electrical equipment.
workshop
Follow 5S System
Repairing, maintenance and testing
of devices
The main devices are :-
• Ring Main Unit (RMU)
• Air circuit Breaker(ACB)
Allocation of repaired RMU & ACB to
subdivisons
Ring main unit (Rmu)
Electrical device that used in the distribution network
 Provide isolation and protection against electrical faults.
 Enhances system reliability
Main functions :-
• Load Switching
• Fault Protection
• Remote Monitoring
Components of RMU
The main components of RMU are :-
 Circuit breaker
 Relay
 Isolators
 SF6 indicator
Testing of RMU
Testing in RMUs ensures reliability and safety

It verifies that circuit breakers and switches are working


correctly & protecting against electrical faults

Some common tests performed on an RMU:-


 Mechanical Operation Test
 Insulation Resistance Test
 Earth fault Testing
 Overload Testing
 Continuity Test
air circuit breaker (acb)
Electrical device that used in the distribution network
used for LT (Low Tension) electrical system i.e 415V
Main functions :-
• Load Switching
• Fault Protection
• Manual & Remote Monitoring
Components of ACB
The main components of ACB are :-
 Contacts
 Relay
 Arc quenching arrangement
Tripping coil
TYPES OF CIRCUIT BREAKERS
AIR-BLAST CIRCUIT BREAKER
It uses a high-pressure air as the OIL CIRCUIT BREAKER
arc quenching medium. When the A high-voltage circuit
contacts are separated, high- breaker in which the arc is
pressure air is forced on the arc drawn in oil to dissipate
through a nozzle. It cools the arc the heat and extinguish
and the arcing products are the arc; the intense heat of
blown away by the blast of the the arc decomposes the
air. The chamber is filled with oil .
high-pressure air after the
extinction of arc which prevents
restrike SULPUR HEXAFLUORIDE
CIRCUIT BREAKER (SF6)
VACUUM CIRCUIT Sulphurhexafluoride
BREAKERS (SF6) gas is used as the
Vacuum circuit breakers are arc quenching medium.
circuit breakers which are The SF6 is an
used to protect medium and electronegative gas and
high voltage circuits from has a strong tendency to
dangerous electrical absorb free electrons
situations
PROTECTIVE RELAYS

It is a sensing device and is


designed to detect operating
conditions on an electric circuit.
It trips the circuit breaker when
fault is detected.

TYPES OF RELAY
 Overcurrent relay
 Differential relay
 Tripping relay
 Directional Relay
 Auxiliary Relay
THANK YOU!