Agilent 4100 MP-AES

Applications,
Accessories,
Software
and
Food and Agriculture Environmental
Questions

S1 CAG EMEAI FY13 |


CAG Agilent| Restricted
EMEAI |
Agilent Restricted | Page
Page11
Agenda for IDO SPS sales training

• Software Overview

•Auto & FLIC Background Correction Overview


• OneNeb Overview
– Examples in Geochemistry, Mining and Minerals Applications
• EGCM Overview
– Examples in Chemical and Petrochemical Applications
• MSIS Overview
– Examples of Food/Agriculture and Environmental Applications
• Questions

S1 CAG EMEAI FY13 |


CAG Agilent| Restricted
EMEAI |
Agilent Restricted | Page
Page22
Key Benefits by Market

• Improved performance
• Matrix handing to match
Chemical / flame AA
Petrochem • Low running costs
• Ease of use

• Fast sequential measurement


Food and • Ease of use
Agriculture • Improved performance
• No flammable gases

• Runs on air
• Improved performance
• Improved Geochemistry/
• No flammable gases
Environmental performance
• Runs on air
Metals • Unattended operation
(non –regulated • Moderate pricing
methods) • Unattended
operation

S1 CAG EMEAI FY13 |


CAG Agilent| Restricted
EMEAI |
Agilent Restricted | Page
Page33
4100 MP-AES Software

S1 CAG EMEAI FY13 |


CAG Agilent| Restricted
EMEAI |
Agilent Restricted | Page
Page44
Auto/FLIC Background Correction &
OneNeb Overview
Examples in Geochemistry, Mining and Minerals
Applications

S1 CAG EMEAI FY13 |


CAG Agilent| Restricted
EMEAI |
Agilent Restricted | Page
Page55
MP-AES Auto Background Correction

Auto uses the spectrum around the peak of interest to create


models.
1. Models of the background (the blank) and the analyte (the
standards) are created during the calibration block
2. For every sample the amount of blank model and the
amount of analyte model in the spectrum is calculated
3. Once the amount of analyte is known the intensity can be
determined
4. Because of very stable plasma structures no need for
correction lamps

S1 CAG EMEAI FY13 |


CAG Agilent| Restricted
EMEAI |
Agilent Restricted | Page
Page66
Example – Blank, 3 Replicates

Measured spectrum Blank substracted spectrum

Variation is below 20 counts/sec

S1 CAG EMEAI FY13 |


CAG Agilent| Restricted
EMEAI |
Agilent Restricted | Page
Page77
Example - Standard , 3 Replicates

Measured spectrum Blank substracted spectrum

1ppm Pb is 3200 counts/sec

S1 CAG EMEAI FY13 |


CAG Agilent| Restricted
EMEAI |
Agilent Restricted | Page
Page88
Example - Sample , 3 Replicates

Measured spectrum Blank substracted spectrum

S1 CAG EMEAI FY13 |


CAG Agilent| Restricted
EMEAI |
Agilent Restricted | Page
Page99
Example - Sample , 3 Replicates
BG correction left/right

Measured spectrum Blank substracted spectrum

S1 CAG EMEAI FY13 |


CAG Agilent| Restricted
EMEAI |
Agilent Restricted | Page
Page10
10
Detection Limit Comparison

Element Wavelength (nm) DL Auto (ppb) DL Off-Peak (ppb)


Zn 213.857 1.7 5.5
Mn 403.076 0.2 0.3
Mn 257.610 0.6 2.8
Cu 324.754 0.2 0.2
K 766.491 1.1 1.2
As 193.759 55 125

S1 CAG EMEAI FY13 |


CAG Agilent| Restricted
EMEAI |
Agilent Restricted | Page
Page11
11
Fast Linear Interference Correction (FLIC)

FLIC adds an extra model to correct for spectral interferences

S1 CAG EMEAI FY13 |


CAG Agilent| Restricted
EMEAI |
Agilent Restricted | Page
Page12
12
FLIC Performance Example – Ni Interference on Co

Same result for both Co lines in high Ni sample

S1 CAG EMEAI FY13 |


CAG Confidentiality |
Agilent| Restricted
EMEAI |
Agilent Restricted Page
Page13
13
FLIC Performance Example – Fe Interference on As

As concentration in the presence of 1000 ppm Fe is <IDL when


using FLIC
Using Auto Using FLIC

S1 CAG EMEAI FY13 |


CAG Agilent| Restricted
EMEAI |
Agilent Restricted | Page
Page14
14
OneNeb Nebulizer

• Robust PFA and PEEK construction


– Inert - resistant to strong acids such as HF
– Resistant to breakage
– Moulded plastic design provides improved nebulizer
to nebulizer reproducibility

• Constant diameter narrow bore tubing through to


nebulizer tip
– Ideal for high solids/particulates
– Improved tolerance to high TDS samples

• Narrow aerosol size distribution provides


improved precision

• Handles a wide flow range from 0.1 to 2 mL/min.


– No sensitivity loss at low flow rates

S1 CAG EMEAI FY13 |


CAG Agilent| Restricted
EMEAI |
Agilent Restricted | Page
Page15
15
Principle of Operation – Inert OneNeb Nebulizer

Tip geometry dimensioned to


allow carrier gas to mix with the
sample
Turbulent mixing of liquid and
gas occurs
– Produces aerosol with a narrow
size distribution range
Droplets mixed into gas flow
No area of low pressure

S1 CAG EMEAI FY13 |


CAG Agilent| Restricted
EMEAI |
Agilent Restricted | Page
Page16
16
Comparison of Droplet Size Distribution
Unique Flow Blurring action increases nebulization efficiency
• 3x greater efficiency than conventional concentric nebulizer
• Improved sensitivity
14

12
Inert OneNeb nebulizer

10
Conventional concentric nebulizer
Proportion
8
of Total

0
0 10 20 30 40 50 60 70 80 90 100

Droplet Size (um)

S1 CAG EMEAI FY13 |


CAG Agilent| Restricted
EMEAI |
Agilent Restricted | Page
Page17
17
Cyanide Leach Solutions – Conventional setup

• CN Leach solution is 0.3% CN, 0.8% NaOH


• Run with Standard Sample intro system
• Blocked concentric nebulizer within 4 hours
• Blocked torch injector within 4 hours

Glass Concentric Nebulizer After < 4hrs of CN/NaOH.


Blocked!

S1 CAG EMEAI FY13 |


CAG Agilent| Restricted
EMEAI |
Agilent Restricted | Page
Page18
18
OneNeb setup

• Orange/green sample tubing


• Double pass spray chamber
• 3 rpm pump rate
• 30s uptake (fast pump on)
• 30s rinse with DI Water (fast pump on)
• Target was 12 hours – a shift in a high throughput lab.

S1 CAG EMEAI FY13 |


CAG Agilent| Restricted
EMEAI |
Agilent Restricted | Page
Page19
19
OneNeb
After ~37 hours of operation

Tip of the OneNeb nebulizer after 37 hours of operation!


Still working perfectly!

S1 CAG EMEAI FY13 |


CAG Agilent| Restricted
EMEAI |
Agilent Restricted | Page
Page20
20
Geochemical, Metals and Mining Ordering Review

S1 CAG EMEAI FY13 |


CAG Confidentiality |
Agilent| Restricted
EMEAI |
Agilent Restricted Page
Page21
21
Dusty Environment Ordering Review

S1 CAG EMEAI FY13 |


CAG Agilent| Restricted
EMEAI |
Agilent Restricted | Page
Page22
22
Applications for the
Agilent 4100 MP-AES
Geochemical, Metals and
Mining Applications

S1 CAG EMEAI FY13 |


CAG Agilent| Restricted
EMEAI |
Agilent Restricted | Page
Page23
23
Instrument Parameters

Parameter Setting
Nebulizer Glass concentric
Spray chamber Single-pass glass cyclonic
Read Time 3s
Replicates 3
Sample uptake delay 10 s
Stabilization time 5s
Fast Pump On (80 rpm)
Background correction Auto
Nebulizer Pressure 140 to 240 kPa (auto optimized)

S1 CAG EMEAI FY13 |


CAG Agilent| Restricted
EMEAI |
Agilent Restricted | Page
Page24
24
4100 MP-AES Method Setup

Sample introduction kit


• Glass concentric Nebulizer – May use OneNeb Nebulizer
• Single pass cyclonic spray chamber
• Orange/Green pump tubing

Easy to use MP Expert software


• Auto background correction
• Auto Optimization for Neb and Viewing position

Improved productivity
• Automate analysis using SPS 3 autosampler
• Fast pump during uptake and rinse

S1 CAG EMEAI FY13 |


CAG Agilent| Restricted
EMEAI |
Agilent Restricted | Page
Page25
25
Traditional Off-Peak Correction for Ag in Digest
Limitations with Off-Peak Correction
• Correction points must be set manually
• Susceptible to spectral interferences

Is this the best correction


point for this matrix?

S1 CAG EMEAI FY13 |


CAG Agilent| Restricted
EMEAI |
Agilent Restricted | Page
Page26
26
Better Alternative - Use “Auto” Correction

Auto background correction uses the spectrum around


the peak of interest to create:
1. Models of the background (the blank) and the analyte (the
standards) – these are created during calibration
2. For every sample the amount of blank model and the
amount of analyte model in the spectrum is calculated
3. Once the amount of analyte is known, the corrected
concentration can be determined

S1 CAG EMEAI FY13 |


CAG Agilent| Restricted
EMEAI |
Agilent Restricted | Page
Page27
27
Auto Correction for Ag in Digest…
… improves detection limits,
is easier to use, Accurate model of the
no method development and no correction sloping background from
points to select the partial peak overlap

Blank Spectrum Standard Spectrum

S1 CAG EMEAI FY13 |


CAG Agilent| Restricted
EMEAI |
Agilent Restricted | Page
Page28
28
Accuracy – Gold in Custom CRMs*

CRM Certified value (mg/L) MP-AES result (mg/L)


1 19.8 19.3
2 7.9 7.4
3 23.1 22.7
4 5.6 5.7
5 57.8 55.3
6 3.1 3.3
7 35.9 35.4
8 8.4 8.9

* These custom CRMs were professionally prepared from solid ore


samples and certified through a round robin test process

S1 CAG EMEAI FY13 |


CAG Agilent| Restricted
EMEAI |
Agilent Restricted | Page
Page29
29
Results for Au in Unknown Samples
MP-AES is the Ideal FAAS Alternative

Sample MP-AES Flame AA Agreement


Result Result with AA Result (%)
(mg/L) (mg/L)
1 0.09 0.09 100
2 0.85 0.84 100
3 5.3 5.1 104
4 13.7 14.4 95
5 20.8 21.8 95
6 4.3 4.1 105
7 1.0 1.0 100

S1 CAG EMEAI FY13 |


CAG Agilent| Restricted
EMEAI |
Agilent Restricted | Page
Page30
30
Comparison of Au values measured with Agilent
4100 MP-AES compared to AAS and ICP-OES

6
MP - AAS correlation
y = 0.9918x - 0.0009
5
MP - ICP correlation
y = 0.974x + 0.0027
Au MP-AES (ppm)

4
MP - AAS
MP - ICP
Correl=1
3 Linear (Correl=1)
Linear (MP - ICP)
Linear (MP - AA)
2

0
0 1 2 3 4 5 6
Au ICP/AAS (ppm)

Very good correlation of Agilent MP-AES Au values in aqua regia


digests compared to ICP-AAS values

S1 CAG EMEAI FY13 |


CAG Agilent
Agilent| Restricted
EMEAI |
Agilent Restricted | Page
Page31
31
Superior Performance – Detection Limits

Analyte Wavelength (nm) Method Flame AA


DL (ug/L) IDL (ug/L)
Au 267.595 4 11
Pt 265.945 13 76
Pd 363.469 0.7 15

MDL = 3σ, 3s read time, 20 blanks

S1 CAG EMEAI FY13 |


CAG Agilent| Restricted
EMEAI |
Agilent Restricted | Page
Page32
32
4100 MP-AES at Newmont Mining Automated Lab

S1 CAG EMEAI FY13 |


CAG Agilent| Restricted
EMEAI |
Agilent Restricted | Page
Page33
33
Standards ~ 0 to 1.0 ppm 267 nm Au Line
0.025 / 0.050 / 0.10 / 0.25 / 0.50 / 1.0
Low Detection Limit
Blank 10% 0.001
Blank 10% -0.001
Blank 10% -0.002
4 blanks before and
Blank 10% 0 after
0.025 0.0235
0.025 0.024 10 consecutive
0.025 0.0241
0.025 0.0242 readings of 0.025
0.025 0.0241 and 0.050 ppm
0.025 0.0238 respectively
0.025 0.0246
0.025 0.0235
0.025 0.0236 25 ppb DL = 1.3 ppb
0.025 0.023
0.050 0.0492
50 ppb DL = 1.9 ppb
0.050 0.0481
0.050 0.0493
0.050 0.0487 AVG DL = 1.6 ppb
0.050 0.049
0.050 0.0498
0.050 0.0486
0.050 0.0484
0.050 0.0477
0.050 0.0491
Blank 10% -0.002
Blank 10% -0.003
Blank 10% -0.003
Blank 10% -0.004
S1 CAG EMEAI FY13 |
CAG Agilent| Restricted
EMEAI |
Agilent Restricted | Page
Page34
34
Typical Detection Limits

Au – 10% aqua regia 1.6 ppb


Au – 0.03% NaCN + 0.08% NaOH 3.0 ppb
Ag – 33% aqua regia 0.6 ppb
Cu – 33% aqua regia 6.0 ppb

S1 CAG EMEAI FY13 |


CAG Agilent| Restricted
EMEAI |
Agilent Restricted | Page
Page35
35
Au – Extended Calibration Range

MP - normal AA range

MP - Extended Range

S1 CAG EMEAI FY13 |


CAG Agilent| Restricted
EMEAI |
Agilent Restricted | Page
Page36
36
Au – Fire Assay Results
Excellent correlation with AA results

FA QC

FA Q

S1 CAG EMEAI FY13 |


CAG Agilent| Restricted
EMEAI |
Agilent Restricted | Page
Page37
37
Au – Fire Assay Results
Excellent correlation with AA results – FA Q
6

3 MP ~ 267 Rational
AA ~ 242 Rational

0
0 1 2 3 4 5 6

S1 CAG EMEAI FY13 |


CAG Agilent| Restricted
EMEAI |
Agilent Restricted | Page
Page38
38
Cu / Ag - 33% Aqua Regia
Excellent correlation with AA results – Batch 3413

100

80

60

MP ~ Cu 324.754 Rational
MP ~ Cu 327.395 Rational
MP ~ Ag 328.068 Rational
40 MP ~ Ag 338.289 Rational
AA ~ Cu 327.395 Rational
AA ~ Ag 328.068 Rational

20

0
1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49

-20

S1 CAG EMEAI FY13 |


CAG Agilent| Restricted
EMEAI |
Agilent Restricted | Page
Page39
39
Cu – 0.3% NaCN + 0.8% NaOH
Correlation with AA results – a bit more work to do

40

35

30

25

MP ~ Cu 327.395 Rational
20
MP ~ Cu 324.754 Rational
AA ~ Cu 327.395 Rational

15

10

0
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23

S1 CAG EMEAI FY13 |


CAG Agilent| Restricted
EMEAI |
Agilent Restricted | Page
Page40
40
Comments from Newmont Mining

“With the MP-AES instrument Agilent seems to have hit a homerun for both gold analysis and base metal
analysis. It provides superior detection limits and vastly expanded calibration range – this enables quick easy
analysis at trace levels as well as eliminates the need for time consuming dilutions of higher grade samples. All
of this at an affordable price of well below that of ICP and only slightly higher than top of the line AA units. ”
- Bobby Joe Reichel
Newmont Mining Corporation

Other Comments –
Very low detection limits for gold compared to AA and graphite furnace

Greatly extended calibration range for gold (0 to 400 ppm)

Extended calibration range for Cu & Ag (Cu-MP up to 125 ppm vs. Cu-AA up to 35 ppm; Ag-MP up to 50 ppm vs. Ag-AA up to 10
ppm.

Ease of operation and training superior to AA

Diagnostic software excellent and easy to use

Would not recommend for of high-cyanide / high-caustic samples at this time

Excellent within-run and between-run stability

Excellent accuracy at all points on the calibration curve

Improved efficiency because of higher linear range

Excellent calibrations without the need for numerous standards

S1 CAG EMEAI FY13 |


CAG Agilent| Restricted
EMEAI |
Agilent Restricted | Page
Page41
41
EGCM Overview

Examples in Chemical and Petrochemical


Applications

S1 CAG EMEAI FY13 |


CAG Agilent| Restricted
EMEAI |
Agilent Restricted | Page
Page42
42
External Gas Control Module (EGCM)

Purge
• O2 in the atmosphere absorbs low UV (<185nm)

• Purge with N2 to remove O2 from the Mono

• Purge takes ~3 hours


• Enables analysis of Sulfur
Add Air to Plasma
• Prevents carbon build up on the injector when running organics
• Reduces the background emissions from the plasma

S1 CAG EMEAI FY13 |


CAG Confidentiality |
Agilent| Restricted
EMEAI |
Agilent Restricted Page
Page43
43
Why Add Air?

1. Prevents carbon build up on the injector when running


organics
2. Reduces the background emissions from the plasma
3. Air is added to the Intermediate flow

S1 CAG EMEAI FY13 |


CAG Confidentiality |
Agilent| Restricted
EMEAI |
Agilent Restricted Page
Page44
44
Solvent background can be minimized with EGCM

S1 CAG EMEAI FY13 |


CAG Confidentiality |
Agilent| Restricted
EMEAI |
Agilent Restricted Page
Page45
45
Solvent background can be minimized with EGCM

S1 CAG EMEAI FY13 |


CAG Confidentiality |
Agilent| Restricted
EMEAI |
Agilent Restricted Page
Page46
46
Mono Purge enables analysis of S in the low UV

• O2 in the atmosphere absorbs low UV (<185nm)


• Purge with N2 to remove O2 from the Mono
• Purge takes ~3 hours
• Enables analysis of Sulfur

S1 CAG EMEAI FY13 |


CAG Confidentiality |
Agilent| Restricted
EMEAI |
Agilent Restricted Page
Page47
47
Chemical and Petrochemical Ordering Review

S1 CAG EMEAI FY13 |


CAG Confidentiality |
Agilent| Restricted
EMEAI |
Agilent Restricted Page
Page48
48
Purging Ordering Review

S1 CAG EMEAI FY13 |


CAG Confidentiality |
Agilent| Restricted
EMEAI |
Agilent Restricted Page
Page49
49
Applications for the
Agilent 4100 MP-AES
Chemical and Petrochemical
Applications

S1 CAG EMEAI FY13 |


CAG Agilent| Restricted
EMEAI |
Agilent Restricted | Page
Page50
50
Challenges with Wear Metal Determinations

Reduce plasma solvent loading


• OneNeb nebulizer + Double Pass spray chamber
• Orange/Green solvent resistant tubing
• 5 rpm

Control the background


• Medium setting for Phosphorus at 213.618 nm
• High setting for all others

Improve Throughput and Ease of use


• SPS 3 with fast pump during sample uptake and rinse
• Auto-optimization of nebulizer pressure and viewing position
• Auto background correction

S1 CAG EMEAI FY13 |


CAG Agilent| Restricted
EMEAI |
Agilent Restricted | Page
Page51
51
4100 MP-AES Solves the Challenges

High vapour • OneNeb nebulizer


pressure from • Reduced sample flow
solvents • Cooled spray chamber

• EGCM
Carbon build up in
injector

• OneNeb nebulizer
Nebulizer
blockage

S1 CAG EMEAI FY13 |


CAG Agilent| Restricted
EMEAI |
Agilent Restricted | Page
Page52
52
Instrument Parameters

Parameter Setting
Nebulizer Inert OneNeb
Spray chamber Double-pass glass cyclonic
Sample tubing Orange/green solvent resistant
Waste tubing Blue/blue solvent resistant
Read Time 3s
Replicates 3
Stabilization time 15 s
Rinse time 45 s
Fast Pump (80 rpm) On
Background correction Auto
Pump speed 5 rpm

S1 CAG EMEAI FY13 |


CAG Agilent| Restricted
EMEAI |
Agilent Restricted | Page
Page53
53
Measured Results for SRM 1085b Wear Metals

Great
recoveries
for all key
elements

S1 CAG EMEAI FY13 |


CAG Agilent| Restricted
EMEAI |
Agilent Restricted | Page
Page54
54
Measured Recoveries on 10 ppm Spike of Gear Oil

Great recoveries
for all key
elements

S1 CAG EMEAI FY13 |


CAG Agilent| Restricted
EMEAI |
Agilent Restricted | Page
Page55
55
Measured Results for Additive Elements

Measured Results vs Certified Values


Element Measured (mg/kg) Certified (mg/kg) Recovery %
P 213.618 301.5 ± 0.1 299.9 ± 7.2 101
Zn 481.053 314.9 ± 0.3 296.8 ± 6.8 106
Mg 285.213 300.6 ± 0.2 297.3 ± 4.1 101
Ca 422.673 279.6 ± 0.1 298 94
Ba 614.171 281.2 ± 0.1 300.1 ± 2.4 94
Measured Recoveries on 10 ppm Spike of Gear Oil
Element Mixed Gear (ppm) Spike (ppm) Recovery %
P 213.618 17.16 26.71 95
Zn 481.053 6.99 17.17 101
Mg 285.213 1.53 11.32 97
Ca 422.673 8.89 19.69 107
Ba 614.171 0.00 9.16 91

S1 CAG EMEAI FY13 |


CAG Agilent| Restricted
EMEAI |
Agilent Restricted | Page
Page56
56
Organics – Long Term Stability

1.5
1.4
1.3
1.2
1.1
1
Normalized Conc

0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
0:00 1:00 2:00 3:00 4:00 5:00 6:00 7:00 8:00

Time (h:mm)

Zn 213.857 nm Si 251.611 nm Fe 259.940 nm Ni 305.081 nm Ag 328.068 nm


Pb 283.305 nm Cu 327.395 nm Mg 285.213 nm Ti 334.941 nm Al 396.152 nm

10 ppm S21. All lines show precision of <1% RSD

S1 CAG EMEAI FY13 |


CAG Agilent| Restricted
EMEAI |
Agilent Restricted | Page
Page57
57
Limits on Target Elements in Diesel Fuel - EN14538

S1 CAG EMEAI FY13 |


CAG Agilent| Restricted
EMEAI |
Agilent Restricted | Page
Page58
58
Instrument Parameters

Parameter Setting
Nebulizer Inert OneNeb
Spray chamber Double-pass glass cyclonic
Sample tubing Orange/green solvent resistant
Waste tubing Blue/blue solvent resistant
Read Time 3s
Replicates 3
Stabilization time 15 s
Fast Pump (80 rpm) On
Background correction Auto
Pump speed 5 rpm

S1 CAG EMEAI FY13 |


CAG Agilent| Restricted
EMEAI |
Agilent Restricted | Page
Page59
59
Method Detection Limits

3σ, 3s read time, 10 blanks

Element Wavelength (nm) MDL (ppb)


Mg 285.213 2.7
Ca 422.673 8.2
Na 588.995 18.7
K 766.491 2.7

S1 CAG EMEAI FY13 |


CAG Agilent| Restricted
EMEAI |
Agilent Restricted | Page
Page60
60
Direct Measurement of Impurities in Gasoline

Same ASTM D6751 limits


•Ca, Mg combined 5 ppm
•Na, K combined 5 ppm

High volatility of the gasoline is a challenge


•Cooled spray chamber -10 oC
•Standard Additions calibration
•Direct measurement of samples

S1 CAG EMEAI FY13 |


CAG Agilent| Restricted
EMEAI |
Agilent Restricted | Page
Page61
61
Instrument Parameters

Parameter Setting
Nebulizer Inert OneNeb
Spray chamber IsoMist cooled spray chamber (-10 oC)
Sample tubing Orange/green solvent resistant
Waste tubing Blue/blue solvent resistant
Read Time 3s
Replicates 3
Stabilization time 30 s
Fast Pump (80 rpm) On
Background correction Off-peak
Pump speed 5 rpm

S1 CAG EMEAI FY13 |


CAG Agilent| Restricted
EMEAI |
Agilent Restricted | Page
Page62
62
Calibrations and Detection Limits

Element Wavelength (nm) Correlation Coeff MDL (ppb)


Mg 285.213 0.99993 2.7
Ca 422.673 0.99934 4.3
Na 588.995 0.99939 5.3
K 766.491 0.99975 29.4

S1 CAG EMEAI FY13 |


CAG Agilent| Restricted
EMEAI |
Agilent Restricted | Page
Page63
63
Spike Recoveries on Gasoline

Gasoline fuel sample spiked with 1.1 ppm S21+K

Element Sample (ppm) Spike (ppm) Recovery %


Mg 285.213 nm < MDL 1.11 100
Ca 422.673 nm < MDL 1.06 95
Na 588.995 nm < MDL 1.11 100
K 766.491 nm 0.05 1.12 96

S1 CAG EMEAI FY13 |


CAG Agilent| Restricted
EMEAI |
Agilent Restricted | Page
Page64
64
MSIS Overview

Examples of Food and Agriculture Applications

S1 CAG EMEAI FY13 |


CAG Agilent| Restricted
EMEAI |
Agilent Restricted | Page
Page65
65
MSIS

S1 CAG EMEAI FY13 |


CAG Confidentiality |
Agilent| Restricted
EMEAI |
Agilent Restricted Page
Page66
66
Multimode Sample Introduction System (MSIS)

S1 CAG EMEAI FY13 |


CAG Confidentiality |
Agilent| Restricted
EMEAI |
Agilent Restricted Page
Page67
67
Nebulization mode

S1 CAG EMEAI FY13 |


CAG Confidentiality |
Agilent| Restricted
EMEAI |
Agilent Restricted Page
Page68
68
Vapour generation mode

S1 CAG EMEAI FY13 |


CAG Confidentiality |
Agilent| Restricted
EMEAI |
Agilent Restricted Page
Page69
69
Dual mode

S1 CAG EMEAI FY13 |


CAG Confidentiality |
Agilent| Restricted
EMEAI |
Agilent Restricted Page
Page70
70
Typical DL’s (ppb)

Analyte Neb Mode Dual Mode


As 90 1.0
Se 126 2.0
Hg 14 0.5

S1 CAG EMEAI FY13 |


CAG Confidentiality |
Agilent| Restricted
EMEAI |
Agilent Restricted Page
Page71
71
MSIS Hg single mode
Calibration 10 points from 0.5 to 5 µg/l

S1 CAG EMEAI FY13 |


CAG Confidentiality |
Agilent| Restricted
EMEAI |
Agilent Restricted Page
Page72
72
MSIS Ordering Review

S1 CAG EMEAI FY13 |


CAG Agilent| Restricted
EMEAI |
Agilent Restricted | Page
Page73
73
High TDS Ordering Review

S1 CAG EMEAI FY13 |


CAG Agilent| Restricted
EMEAI |
Agilent Restricted | Page
Page74
74
Applications for the
Agilent 4100 MP-AES
Food and Agricultural
Applications

S1 CAG EMEAI FY13 |


CAG Agilent| Restricted
EMEAI |
Agilent Restricted | Page
Page75
75
Sample Types

Wide Range of Matrices


• Dairy, Meat, Fish, Grain, Vegetables, Fruit, etc
• Processed goods
• Canned, frozen, dried and preserved food
• Drinks (soda, tea, coffee, alcoholic beverages etc.)
• Preservatives, “fillers” and additives such as calcium carbonate
• “Nutraceuticals”

Other Important Samples


• Water (used for irrigation)
• Soil
• Fertilizer
• Food additives / flavors / colors
• Packaging material

S1 CAG EMEAI FY13 |


CAG Agilent| Restricted
EMEAI |
Agilent Restricted | Page
Page76
76
Which Elements are Monitored in Foods?

Toxic trace elements

• Low level analysis – typically ppb levels


• As, Cd, Hg, Pb, Tl, Cr

Common elements that are toxic in excess

• Typically range from ppb to ppm level


• Al, Ni, Cu, Zn, Se, Mo, Sn

Essential minerals

• Can cover a wide range from ppm to % levels


• Na, Mg, P, S, K, Ca, Fe

S1 CAG EMEAI FY13 |


CAG Agilent| Restricted
EMEAI |
Agilent Restricted | Page
Page77
77
Food Applications – Solving the Challenges

• Standard Sample Introduction


Robust Sample • Concentric nebulizer

Introduction • Single pass spray chamber

• Improved throughput compared to Flame


Many Elements AA
• Auto background correction
Per Sample • CsCl buffer

• Over 14,000 wavelengths to chose from for


Wide Dynamic low and high concentration
• Lower detection limits for P compared to
Range Flame AA

S1 CAG EMEAI FY13 |


CAG Agilent| Restricted
EMEAI |
Agilent Restricted | Page
Page78
78
Instrument Parameters

Parameter Setting
Nebulizer Glass concentric
Spray chamber Single pass glass cyclonic
Sample tubing White/white
Waste tubing Blue/blue
Read Time 10 s
Replicates 3
Stabilization time 10 s
Fast Pump On (80 rpm)
Pump speed 12 rpm
Nebulizer pressure 160 – 180 kpa (auto optimized)
Background Correction Auto

S1 CAG EMEAI FY13 |


CAG Agilent| Restricted
EMEAI |
Agilent Restricted | Page
Page79
79
Method Detection Limits

S1 CAG EMEAI FY13 |


CAG Agilent| Restricted
EMEAI |
Agilent Restricted | Page
Page80
80
Measured Results for CRM Food Samples

NIES No. 10c Rice Flour High Purity Stds CRM Wheat Flour

* Reference values only

S1 CAG EMEAI FY13 |


CAG Agilent| Restricted
EMEAI |
Agilent Restricted | Page
Page81
81
Measured Results for CRM Food Samples

NIST 1577 Bovine Liver High Purity Stds CRM Oyster Tissue

* Reference values only

S1 CAG EMEAI FY13 |


CAG Agilent| Restricted
EMEAI |
Agilent Restricted | Page
Page82
82
Feedback from Sachsenforst, Germany (soil lab):

“The results for our aqua regia soil extract samples are convincing,
and those results are in very good agreement with the round robin,
which was performed Europe wide on those samples.”

- Frank Symossek
Sachsenforst

S1 CAG EMEAI FY13 |


CAG Agilent| Restricted
EMEAI |
Agilent Restricted | Page
Page83
83
Feedback from CERA Laboratory. India

“We are using MP-AES instrument for last couple of months, and we
found instrument is best to detect trace metals compare to AAS. In
AAS sensitivity for B and P is very poor and fuel cost is very high,
whereas using the MP-AES, sensitivity is very, very good and fuel cost
is very low. In AAS, with elements like Al, Ca, Mo,Ti, V, Si etc, it
consumes high quantities of Acetylene and Nitrous Oxide gas, and is
very tricky - whereas using the MP-AES, it is very easy to detect.
There is also no need to change Hollow Cathode Lamps which is time
consuming and costly.”

- S.S. Mhatre
CERA Laboratory

S1 CAG EMEAI FY13 |


CAG Agilent| Restricted
EMEAI |
Agilent Restricted | Page
Page84
84