8800A Production Training-2020

You might also like

Download as pptx, pdf, or txt
Download as pptx, pdf, or txt
You are on page 1of 25

Aeon8800A anesthesia workstation

Service Department
Aeon8800A anesthesia workstation

Aeon8800A Features

• Accurate tidal volume delivery


• Stable agent delivery
• Advanced breathing system
• Safe fresh gas delivery
Aeon8800A anesthesia workstation
Accurate and stable tidal volume delivery

Work together with American expert team


More than 100 patents
Accurate small tidal volume control (minimum 10mL)

U.S. patents No.US8,066,003 B2


Aeon8800A anesthesia workstation

Compensation

• Fresh gas compensation


Flow rate of O2,N2O,AIR monitoring respectively, combining the overall
monitoring;
Data transmission millisecond feedback

• Compliance compensation
Through compliance and leak testing directly improve the accuracy of tidal volume

• Altitude compensation
Automatic compensation for altitude.
Can work as high as 5000 meters environment.
Aeon8800A anesthesia workstation

Tidal volume stability test


600

500

400
PF300 Vte 监
300
测1
200
87A Vt 监测
1
100

0
0 100 200 300 400 500 600

Conclusion:
The delivered tidal volume that measured from the patient side is close to the set value.
Compliance compensation, Fresh gas compensation, altitude compensation and leakage
compensation make the delivery What You Set Is What the Patient Will Get.
Aeon8800A anesthesia workstation

VP300/500 vaporizer

Reliable, safe, accurate


Interlock system

Big agent volume

With temperature, pressure and


flow compensation

Support Sev, Iso, Enf and Hal

Support different filling methods,


including
Pour fill, Key fill, Quik fil

Support both Selectatec and Plug-in


interface
Aeon8800A anesthesia workstation

Advanced breathing system


• New generation design, aluminum alloy, Wholly
autoclavable
• Fast-release function by APL valve improve the efficiency
of resuscitation after surgery
• Breathing system warmer for avoid condensation build-up
during low-flow anesthesia
• Mass type flow sensor, No consumables for sampling
• Ultra-light ceramic one-way valve diaphragm is more
sensitive which meet the respiratory management of
pediatric anesthesia
• Multiple canister options, CLIC prepack compatible
• CO2 bypass option, Supports replacement of sodium lime
during surgery for longer operating time
Aeon8800A anesthesia workstation
Intelligent delivery for fresh gas

• Digital Flowmeter make fresh gas


flow setting easier and more
precise.

• It can set the flow rate of oxygen


and mixed gas, or set the total
flow rate and oxygen
concentration
Aeon8800A anesthesia workstation
Intelligent delivery for fresh gas

• Digital Flowmeter with ECO-Optimizer can help the clinical operation on


low flow anesthesia

• The ECO-Optimizer indicates the recommended fresh gas flow setting


according to the setting value and the minimum O 2 needed of the
patient. It enables a safe low flow, and reduce agent and gas waste.

• The mechanical alternative O2 flow meter is designed to be able to use


even when power failure
Aeon8800A anesthesia workstation

•C o m p r e h e n s i v e m o n i t o r i n g f u n c t i o n

• 15" TFT LCD color touchscreen, displays


patient data with paging data area and
waveforms.

• In addition to traditional monitoring


parameters, special monitoring parameters,
such as Driving Pressure(DP) and stress
index(SI), are provided to guide clinicians
in adjusting ventilation parameters.

• Provides medical gas consumption


calculations: including O2, N2O and Agent.
And provide calculations of CO2 production
Aeon8800A anesthesia workstation

Comprehensive monitoring function

•Continuous trend information together with time discrete events


are stored and shown in the table or chart.
•Spirometry loops can be stored for future reference, allowing
clinicians the ability to better understand changes in the patient’s
response to therapy.
•The data communications export is supported to connect to
hospital IT systems.
Aeon8800A anesthesia workstation
Powerful clinical tool
•The Aeon8800A provides many clinical tool programs to help clinical operations, make the clinical operation more convenient.
•For example, use PV tool to measure static compliance, use lung recruitment tool to help manage lung ventilation issues during general
anaesthesia, also provide multiple types of Cardiopulmonary bypass mode (CBP) etc.
Aeon8800A anesthesia workstation

Alarm system
• Clinical and technical alarms
• Alarms for pressure, volume, concentration etc.
• 500 items of alarm log

Clear alarm message


• Multiple alarms
• 3 levels
• Alarm log
Aeon8800A anesthesia workstation
MASIMO Capnography and Multigas monitoring

CO2 module
FiCO2, EtCO2, waveform

Agent module
Support 5AA, N2O and CO2
Auto identification
MAC value calculation

Support main-stream modules and


side-stream modules

Sampling flow of side-stream


module return to system
Aeon8800A anesthesia workstation

Paramagnetic O2 sensor
Configure with side-stream modules

Using world famous supplier


• Not consumable
• Fast feedback
• Not need frequently calibration
• Environment friendly, comply with RoHS
• Must work with side-stream gas module
Aeon8800A anesthesia workstation

Data Storage
Trend table
Trend information together with time discrete events are stored and shown in the table
Maximum 17 parameters can be stored
The interval Is adjustable , Maximum 720 hours of trend data
Can be imported to USB devices
Aeon8800A anesthesia workstation

Data Storage

Trend chart
Continuous trendinformation are stored and shown in the chart, including
Pressure,CO2,Agent,MV,VT,O2
The machine shall remember the 72 hours trend chart
Aeon8800A anesthesia workstation

Humanized interface

15-inch TFT touch screen

Touch screen plus rotary knob, make the use easy and efficient

Color coded parameters and waveforms

3 waveforms simultaneously

Customized ventilation parameters and alarm limits according to


the requirements of hospital (Site Default)
Aeon8800A anesthesia workstation

Pressure
• IPPV • PS/CPAP
• SIMV-VC • PCV • PCV-VG
• SIMV-PC • SIMV-VG
Volume Advanced

ICU grade ventilation capability


Aeon8800A provides complete anesthesia ventilation capabilities that include traditional and new
ventilation modes, provide more flexibility in ventilation strategy, suitable for various patients and
operations
Aeon8800A anesthesia workstation

PCV-VG

Pressure Control Ventilation with Volume Guaranteed (PCV-VG) is a controlled ventilation mode combining
the advantages of VCV and PCV for patients requiring controlled mechanical ventilation. PCV-VG delivers
the desired tidal volume to the patient, offers the benefits of PCV with lowest inspiratory pressure , provide
better oxygenation at lower peak inspiratory pressures and higher mean airway pressure compared to
volume control ventilation

SIMV-VG

Synchronized Intermittent Mandatory Ventilation with Volume Guaranteed (SIMV-VG) delivers a setting rate
of Pressure Control Ventilation with Volume Guaranteed (PCV-VG) to the patient. The patient can breathe
spontaneously between mandatory breaths. Pressure support can be used to support the spontaneous
breaths
Aeon8800A anesthesia workstation

Auxiliary O2 flowmeter
Integrated independent O2 flowmeter
Provide extra choice for O2 supply to the patient

Auxiliary high pressure outlet


Gas supply for other equipment
Aeon8800A anesthesia workstation

Anesthetic Gas Scavenging System


Meet ISO 8835-3 International Standard
Suction pressure can be adjusted to different requirement
Good readability with buoy indication
Meet the purification requirement of laminar flow in operation room
Simple operation, easy connection and convenient maintenance
Aeon8800A anesthesia workstation

Enhanced Ergonomics

Better clinical experience


Aeon8800A anesthesia workstation

More functions:

Patient monitors

CO2, N2O, 5 AA analysis

Agent consumption calculation

Driving gas outlet

Suction system

Scavenging system (AGSS)

Pendant mount adapter

Cylinder yokes

ACGO with protected device


……
THANKS!

You might also like