Professional Documents
Culture Documents
8800A Production Training-2020
8800A Production Training-2020
8800A Production Training-2020
Service Department
Aeon8800A anesthesia workstation
Aeon8800A Features
Compensation
• Compliance compensation
Through compliance and leak testing directly improve the accuracy of tidal volume
• Altitude compensation
Automatic compensation for altitude.
Can work as high as 5000 meters environment.
Aeon8800A anesthesia workstation
500
400
PF300 Vte 监
300
测1
200
87A Vt 监测
1
100
0
0 100 200 300 400 500 600
Conclusion:
The delivered tidal volume that measured from the patient side is close to the set value.
Compliance compensation, Fresh gas compensation, altitude compensation and leakage
compensation make the delivery What You Set Is What the Patient Will Get.
Aeon8800A anesthesia workstation
VP300/500 vaporizer
•C o m p r e h e n s i v e m o n i t o r i n g f u n c t i o n
Alarm system
• Clinical and technical alarms
• Alarms for pressure, volume, concentration etc.
• 500 items of alarm log
CO2 module
FiCO2, EtCO2, waveform
Agent module
Support 5AA, N2O and CO2
Auto identification
MAC value calculation
Paramagnetic O2 sensor
Configure with side-stream modules
Data Storage
Trend table
Trend information together with time discrete events are stored and shown in the table
Maximum 17 parameters can be stored
The interval Is adjustable , Maximum 720 hours of trend data
Can be imported to USB devices
Aeon8800A anesthesia workstation
Data Storage
Trend chart
Continuous trendinformation are stored and shown in the chart, including
Pressure,CO2,Agent,MV,VT,O2
The machine shall remember the 72 hours trend chart
Aeon8800A anesthesia workstation
Humanized interface
Touch screen plus rotary knob, make the use easy and efficient
3 waveforms simultaneously
Pressure
• IPPV • PS/CPAP
• SIMV-VC • PCV • PCV-VG
• SIMV-PC • SIMV-VG
Volume Advanced
PCV-VG
Pressure Control Ventilation with Volume Guaranteed (PCV-VG) is a controlled ventilation mode combining
the advantages of VCV and PCV for patients requiring controlled mechanical ventilation. PCV-VG delivers
the desired tidal volume to the patient, offers the benefits of PCV with lowest inspiratory pressure , provide
better oxygenation at lower peak inspiratory pressures and higher mean airway pressure compared to
volume control ventilation
SIMV-VG
Synchronized Intermittent Mandatory Ventilation with Volume Guaranteed (SIMV-VG) delivers a setting rate
of Pressure Control Ventilation with Volume Guaranteed (PCV-VG) to the patient. The patient can breathe
spontaneously between mandatory breaths. Pressure support can be used to support the spontaneous
breaths
Aeon8800A anesthesia workstation
Auxiliary O2 flowmeter
Integrated independent O2 flowmeter
Provide extra choice for O2 supply to the patient
Enhanced Ergonomics
More functions:
Patient monitors
Suction system
Cylinder yokes