ELID 2008 IDT

EL5xxx Hardware and System Configuration

Company
LOGO
Hardware and System Configuration

1.
1.Hardware
HardwareOverview
Overview

2.
2. EL5xxx
EL5xxx series
seriesController
Controller

3.
3.Reader
Reader Interface
InterfaceUnit
Unit (RIU)
(RIU)

4.
4.Accessories
Accessories

5.
5. System
System Configuration
Configuration
Matrix V Hardware
Hardware Overview
EL5xxx Series Controller
MAIN CONTROLLER.
 EL5xxx

Multi-door controller

Intel Chipset

Built in LAN

THE FAMILY
 EL5000 – 8 Doors

Combination of Door Access System, Car Park, Time Clock, and Combo mix
mode.
 EL5002

2 doors controller
 EL5004

4 doors controller
 EL5500

16 doors controller
 EL5000L

8 Lift controller up to 32 Floors/ Lift
 EL5030

5 doors controller

** Proprietary encryption…
EL5000 Controller

LAN Port
LCD Display
E-BUS1

E-BUS2

Temper Switch,
AC fail,
Battery Shunt Battery low

A/C Power Socket

Keypad
I/O Expansion Port

EPROM (ODD)

EPROM (EVEN)

Reset Button
EL5000 v 3.x.x
 Cold Start Mode - EL5000V3 mode (A) or ET5000
mode (B)
 EL5000V3 mode

Card Database - from 33,000 to 38,165.

Transaction Database - from 22,000 to 30,000

Mix mode – Door access with simple Time Clock feature.
 ET5000 mode

Card Database - 19,846.

Time Clock Access Level (i.e, you must clock-in or out at
certain reader and at certain time)

Card holder's database can now holds 16 character
name and will be displayed on the EK9i when badge
card.

Reason code support – To leave the attendant reason.
 Timers – from 24 to 99 per door
 Timezones – from 10 to 99 per door
 Holiday – from 20 to 40
 16 char door label support for EK9i
 The Mixed mode now support Reason Code
Selection (20 sets, each with 16 character long text)
 Enhanced baud rate speed: 9600 and 57600bps
EL5002 Controller
Reset
Button

LCD
Display EPROM (ODD)

Battery EPROM (EVEN)


Shunt

Door # 1
Door # 2
* In & Out reader
* In & Out reader
* Push button
* Push button
* Door Sensor
* Door Sensor
* EM Lock
* EM Lock
Keypad

I/O Expansion Port


EA 8
EA 8
EPROM
(ER505) Temper Switch,
AC fail,
D/C Power Socket Battery low E-BUS to EFD 80 LAN Port
EL5004 Controller
 Multi-function, configurable for either Card access,
Carpark control, Time clock or Mixed Mode
 Enhanced anti-passback capabilities
 40 holidays
 99 timezones, with 99 timers, each with 4 time intervals
 Escorting dual-card mode for high security door
 Special Card capability to arm and disarm sensors
 2 MB on-board memory (Up to 33,000 cardholders and
22,000 transactions)
 Status LEDs for DC Power, Database Health, CPU
heartbeat, Ethernet and RS485 communication
 Dedicated inputs for tamper, battery low and AC power
failure status
 Advanced Encryption Standard 128-bit secured
communication algorithm
 Local board is 2 doors + Connect to RIU for 2 doors.
 Enhanced baud rate speed: 9600 and 57600bps
EL5004 Controller
Reset
Button

LCD
Display EPROM (ODD)

Battery EPROM (EVEN)


Shunt

Door # 1
Door # 2
* In & Out reader
* In & Out reader
* Push button
* Push button
* Door Sensor
* Door Sensor
* EM Lock
* EM Lock
Keypad

I/O Expansion Port


EA 8
EA 8
LAN Port
EPROM
(ER505) Temper Switch,
AC fail,
D/C Power Socket Battery low E-BUS to RIU for Door 3, and Door 4
EL5500 Controller
 EL5500 flexible mode

120,000 Card Users, 23,000 Transactions

33,000 Card Users, 160,000 Transactions

50,0000 Card Users, 80,000 Transactions
 ET5500 card-db size is 61,000
 3 E-bus - 2-wire RS-485 channels

E-Bus 1 and E-Bus 2 connect to RIU

E-Bus 3 connect to EFD.
 Enhanced baud rate speed: 9600 and
57600bps
EL5500 Controller

Battery Shunt
LAN Port
LCD Display

E-BUS1

E-BUS2

E-BUS3

Keypad
I/O Expansion Port

EPROM (ODD)

EPROM (EVEN)

Temper Switch, AC fail, D/C Power Socket


Battery low Reset Button
EL5030 Controller
 5-door Networked Door Access - Serve as the cost-effective
family member for the IP-based Matrix V Integrated Security
System.
 1 channel RS-485 communication bus. Connect up to 4 unit of
ER62 RIU for 4 ENTRY and 4 EXIT card readers.
 Store up to 4,000 cardholders and holds 10,000 transactions in
case the communication is disrupted with the server host.
 32-bit low-power and high-performance microprocessor
 IP addressable - Ethernet TCP/IP network, or ADSL
modem/router with Dynamic DNS support
 12VDC /1A input power requirement with single CR2032 Lithium
battery cell for data-backup
 Multi-functions, configurable as either Standard card access,
Car-park control or Time-clock Mixed Mode
 Enhanced anti-passback capabilities (hard/soft/alarm)
 40 holidays set, 10 timezones, with 24 timers, each with 2 time
intervals
 Status LEDs for DC Power, Database Health, CPU heartbeat,
Ethernet and RS485 communication
 Dedicated inputs for tamper, battery low and AC power failure
status
EL5030 Controller

EL5030 Typical Configuration


E-BUS

D/C Power
Socket
LAN Port

EL5030 * Door 1
Push Button
In Reader
EM Lock, Door Sensor
Door1

* Door 2
In Reader Push Button
Door2 EM Lock, Door Sensor

In Reader * Door 3
Door3 Push Button
EM Lock, Door Sensor
Reader Interface Unit
ER505 Reader Interface Unit
EA 8 EA 8

Door # 1 Door # 2
* In & Out
* In & Out reader
reader
* Keypad
* Keypad
* Push button
* Push button
* Door Sensor
* Door Sensor
* EM Lock
* EM Lock

Dip Switch EPROM

Reset Button
Temper Switch,
RS485 Socket
AC fail, D/C Power Socket
Battery low
ER504 Reader Interface Unit

EA 8
Door # 1
* In & Out reader
* Keypad
* Push button EPROM
* Door Sensor
* EM Lock
Reset Button

Dip Switch

Temper Switch,
RS485 Socket AC fail, D/C Power Socket
Battery low
ER 502 Reader Interface Unit
 Single door R.I.U.
 2 reader -1 In and 1 Out
 Onboard 7 segment LED for unit number display
 DIP switches for changing unit number.
 7 input point - Panel tamper switch, door sensor, push button,
AC fail, battery low, sensor 1 and sensor 2.
 4 relay output - EM lock or door latch, GP output 1, GP output
2 and buzzer.
 EK9S up to 50m length.
 EA8 I/O expansion board.
 Enhanced baud rate speed: 9600 and 57600bps
 Support 4x3 keypad
 Support door access and car park mode
 Wiegand input and output which support simultaneous
reading
 Reader format supports:

Wiegand 26-bit (HID, EM, Mifare)

Free Wiegand (max. 40-bit)(HID, EM, Mifare)

Barcode (2of5, 3of9)
ER 502 Reader Interface Unit

EA 8 RS485 Socket

EK9S Dip Switch


Keypad

LED – Unit Number


Baud Rate
Jumper
4x3 Keypad
In reader

EPROM

Temper Switch,
AC fail,
Battery low
Out reader

* Sensor 1
* Sensor 2

* Push button
* Door Sensor * GP output 1
* EM Lock * GP Output 2

A/C Power Socket


Reset Button
EK9i LCD Reader Interface Unit

 2 models

Blue LCD (2x16 line)

Yellow LCD (Single line, No Backlit)
 Single door R.I.U.
 2 reader -1 in and 1 out
 LCD menu for setting- unit number, baud rate and etc.
 6 input point - Panel tamper switch, door sensor, push button,
AC fail, battery low, sensor 1.
 2 relay output - EM lock or door latch, GP output 1 or buzzer.
 Option connect to EL3Z relay board for better security
 Enhanced baud rate speed: 9600 and 57600bps
 Wiegand input and output which support simultaneous reading
 Reader format supports:

Wiegand 26-bit (HID, EM, Mifare)

Free Wiegand (max. 40-bit)(HID, EM, Mifare)
 Support messaging, and door label
 Reader Beeper control
 Random tone keypad
 Support offline reader access mode (up to 10 cards)
 Power Saving Mode – Auto off when idle
EK9i LCD Reader Interface Unit

Cold Start Button

Temper Switch

Reset Button

RS485 Socket

EPROM

GP Output

In Reader

* EM Lock
* Push Button
Buzzer
* Door Sensor
* Key Switch
* Sensor / Tamper
Out Reader

Battery Low
AC Fail
D/C Power Socket
Nuevo LCD Reader Interface Unit

 LCD display – 16 x 2 Amber color


 Cap Sense Keypad – Button-less backlit keypad with dimming
effect
 High quality voice indicator – adjustable volume with random tone
when touch keypad
 USB connection for firmware upgrade and setting.
 Elegant curve design with mirror finish and scratch resistant
 Power Saving Mode – Auto off when idle
 Single door R.I.U
 Build-in Reader and connect to 1 out reader - support
simultaneous reading
 LCD menu for setting - unit number, baud rate and etc
 Enhanced baud rate speed: 9600 and 57600bps
 Support messaging, and door label
 Reader format supports:

Wiegand 26-bit (HID, EM, Mifare)

Free Wiegand (max. 40-bit)(HID, EM, Mifare)
 All inputs (tamper switch, door sensor, push button, sensor 1 and
2, AC fail and battery low) and all outputs (door latch and GP 1)
are routed to an external I/O board
 Support offline reader access mode (up to 10 cards)
 Option - Release door when host controller is offline (break down)
Nuevo LCD Reader Interface Unit

Nuevo LCD Keypad With build-In Nuevo Out Reader


Reader
ER62 Reader Interface Unit

 16-bit low-power and high-performance


microprocessor with 128KB Flash memory
 2 reader ports configurable either as 1 door
with ENTRY/EXIT readers or 2 door with
ENTRY reader and EXIT PUSH BUTTON
 RS-485 communication with 57600 baud or
9600 baud
 Support Wiegand-26, Free Wiegand, HID,
EM, MIFARE, ABA Magnetic Cards and
Barcode Cards
 4 sensor inputs
 6 open-collector transistor outputs
 12VDC / 0.5A power requirement
ER62 Reader Interface Unit

Connect to EL5030

2-wire
RS485 from
EL5030

In Reader
ER62 Out Reader
EFD 80 Field devices

8 On Board
16 On Outputs
Board
Inputs +
24 expansion
Outputs
EA5168 Field devices

EA 5168 Overview

8 On Board
Outputs

8 On Board
Inputs
EA8 Field devices

2 On Board
inputs

6 On Board
Outputs
EL3Z Field devices

* Door Sensor
* AC Fail
* Push Button
* Interlock

Outputs
Accessories

EA584 star hub


 Connect the RS485 device into star
topology instead of the conventional
daisy chain topology.
 Can connect up to 4 Devices
 Connection usage - RIU and I / O
Field Devices
 Each connection distance is up to
1km
 12VDC
EA584 Configuration
ES8A Relay Board

Connect to EFD

8 On Board Outputs
System Configuration

 EL 5000

(128 input and


256 output)

(64 input and 64


output)
System Configuration

 EL 5500

(128 input and


256 output)

(64 input and 64


output)
System Configuration

 EL 5002

(128 input and 256 output)

(64 input and 64


output)
System Configuration

 EL 5004

(64 input and 64


output)
System Configuration

 EL 5030 – Option 1
* Door 1
Push Button
In Reader EM Lock, Door Sensor
Door1
EL5030 * Door 2
In Reader Push Button
Door2 EM Lock, Door Sensor

In Reader * Door 3
Door3 Push Button
EM Lock, Door Sensor

In Reader
Door4 In Reader
ER62 Door5

* Door 4 * Door 5
Push Button Push Button
EM Lock, Door Sensor EM Lock, Door Sensor
System Configuration

 EL 5030 – Option 2
* Door 1
*Door 3
EM Lock, Door Sensor *Door 3 In Reader Our
ER62 Reader
*Door 1 In Reader
EL5030
2 wire RS485
*Door 1 Our Reader
* Door 3
EM Lock,
*Door 2 In Reader Door Sensor

* Door 2 ER62
EM Lock, Door Sensor
*Door 2 Our Reader *Door 4
ER62 Our
Reader
*Door 5 Our Reader

*Door 4 In Reader * Door 4


*Door 5 In Reader ER62 EM Lock,
Door Sensor

* Door 5
EM Lock, Door Sensor
QnA