Professional Documents
Culture Documents
MJH-19022 BeneHeart C Series - Product Training - V1.0 - EN
MJH-19022 BeneHeart C Series - Product Training - V1.0 - EN
Overview
Key Features
Configuration
Accessories
Configuration Tool
AED Trainer
Price
BeneHeart C series
D1 pro
C2
D1 pub
C1A
Performance
Language switch
Shock button
Status indicator *only for semi-auto
6 © 2018 Mindray Confidential
Overview
Network
connector
*optional for 4G
USB connector
Smart & Easy Fast & Powerful Reliable & Durable Lower Cost &
More Trust
Applying pads
Analyzing
heart rhythm
Shock advised
CPR process
12 © 2018 Mindray Confidential
Detailed Animation Guide
Adult Mode Child Mode
Applying pads
Semi-auto
Analyzing
heart rhythm
Shock advised
Fully auto
3
2
1 3
2
1
CPR process
13 © 2018 Mindray Confidential
Detailed Animation Guide
Adult Mode Child Mode
Applying pads
Compression
Analyzing
heart rhythm
Shock advised
Ventilation
CPR process
14 © 2018 Mindray Confidential
Intelligent
ResQNavi TM
ResQNaviTM helps to recognize the challenge of the rescuer encounters in time, and provides
more detailed operation guidance for the unskilled rescuer through the change of both
animation and voice prompts.
ResQNaviTM provides comprehensive CPR navigation for rescuers in accordance with the
latest AHA/ERC guidelines to help rescuers perform high quality CPR.
ResQNaviTM technology can continuously encourage the rescuer in the CPR process and help
to achieve the goal for saving a life , just like a personal coach at side.
20 compressions
Vigorous remaining.
Push down hard.
Start Finish
Follow the
100 50 compressions Stop CPR
metronome to give
compression remaining
200 compressions
s remaining Contionue to push
approximately.
down hard.
Exhausted
Faster Time to 1 st
Shock
Success rates for defibrillation drop every second.
BeneHeart C series is equipped with new QShockTM technology. With the QShockTM,
we are able to increase the chance of a successful defibrillation.
Power on in 2s Charging in 0s
21 © 2018 Mindray Confidential
QShockTM
Time to 1st Shock
ZOLL First
29 s
AED3 shock
Physio-Control First
20 s
CR2 shock
Mindray First
7s
C series shock
Applying Shock
pads advised
Applying Shock
pads advised
Power First
QShockTM on
VF analysis
shock
Charging
(Background)
-- Part 7
https://www.ahajournals.org/doi/10.1161/CIR.0000000000000261
25 © 2018 Mindray Confidential
2015 ERC Guideline
https://cprguidelines.eu/sites/573c777f5e61585a053d7ba5/content_entry573c77e35e61585a053d7baf/573c78145e61585a083d7bcf/files/S0300-9572_15_00328-7_main.pdf?
26 © 2018 Mindray Confidential
2016 ANZCOR Guideline
Human studies involving BTE waveforms have not shown harm as
indicated by biomarker levels, ECG findings, and ejection fractions
with energy levels up to 360J.
ANZCOR suggest if the first shock is not successful and the
defibrillator is capable of delivering shocks of higher energy, it is
reasonable to increase the energy to the maximum available for
subsequent. Escalating shock energy may prevent the risk of
refibrillation and is in line with current practices.
--11.4
file:///C:/Users/50215231/Downloads/anzcor-guideline-11-4-elect-jan16.pdf
27 © 2018 Mindray Confidential
2015 ILCOR Consensus
… termination rates of subsequent refibrillation were
unchanged when using fixed 120 or 150 J shocks,
respectively, and another … showed termination rates of
refibrillation declined when using repeated 200 J shocks,
unless an increased energy level (360 J) was selected.
We suggest an escalating defibrillation energy protocol to
prevent refibrillation.
The lack of studies showing myocardial injury from biphasic
makes it reasonable to consider increasing defibrillation
energy levels when delivering shocks for refibrillation if the
energy dose delivered by the defibrillator can be increased.
--Part 4
28 https://cprguidelines.eu/sites/573c777f5e61585a053d7ba5/content_entry573c77e35e61585a053d7bac/573c77f25e61585a053d7bbc/files/S0300-9572_15_00363-9_main.pdf?
© 2018 Mindray Confidential
360J ≠ 200J + 160J
CHALLENGE
THE
e Hea
ger si z v ier
Big wei
ght
EN1789 Road Ambulance EN13718-1 Air Ambulance RTCA DO-160G Civil Aviation
IEC60601-1-12 Both Road and Air Ambulance
Battery Life 5 years 5 years 4 years 4 years 4 years 4 years Pads Life 5 years 5 years 4 years 2 years 2 years 3 years
Replacement Replacement
1 time 1 time 2 times 2 times 2 times 2 times 1 time 1 time 2 times 4 times 4 times 3 times
Frequency* Frequency*
33 a 10-year
*taking lifecycle
© 2018 as an Confidential
Mindray example
Lower Cost & More Trust
for Daily Maintain
Complete Overview of
all AEDs
• Power-on status
• Rescue event
38 ©*requiring
2018 Mindray Confidential
to connect with AED-Alert system
Summary
7 〃 TFT Screen ○ ○ ● ●
Defibrillation mode Semi-auto Fully-auto Semi-auto Fully-auto
Shock button ● ○ ● ○
Switch to Adu/Ped Mode ● ● ● ●
Language selection Up to 3 languages Up to 3 languages Up to 3 languages Up to 3 languages
USB port for data output ● ● ● ●
Pre-connected Adult/Pediatric
● ● ● ●
Pads
Auto-ID for Adu/Ped Pads ● ● ● ●
Li-MnO2 Battery (disposable,
● ● ● ●
5-year)
CPR feedback Optional Optional Optional Optional
Wi-Fi for AED-Alert system Optional Optional Optional Optional
4G for AED-Alert system Optional Optional Optional Optional
41 © 2018 Mindray Confidential
C series vs. D1 pub
BeneHeart C series BeneHeart D1 pub
PN: 115-065177-00
47 © 2018 Mindray Confidential
Configurable Setup Options
Date
Time G
Shock
Languag e
series
e n A CPR
Default C
Voice er E mode
energy P Auto test T
recording al D CPR
Initial R time e
Voice S S voice Ne
CPR S Auto test st
volume et et prompt tw
ECG et period S or
Brightnes u u
display u Transmis et k
s p p
Se
Auto p sion u
Patient tu
release interval p
type p
48 © 2018 Mindray Confidential time
7 AED Trainer
Speaker Screen
• The volume can be adjusted • The interface display is basically the
via the remote control same as C2.
CPR duration
Discharge
mode
Number of shocks
• S: semi-auto delivered
• F: fully auto
System boot time
Standard scenario
Battery status indicator
• Support 6 standard
scenarios*
Simulation mode
• Support 4 simulation mode* Volume indicator
• : mute
• : small
• : medium
• : large
53 *See the©remote control part
2018 Mindray for details .
Confidential
Remote Control for AED Trainer
Infrared transmission
Support to control multiple AED
trainer in close range
Support to simulate multiple
emergency scenarios
DC 3V, standard with AAA
Batteries Alkaline 1.5V *2
Compatible with other brands of
disposable AAA batteries
Remote control for
AED Trainer
• PN: xxx-xxxxxx-xx
Material: nylon
Size: 300*230*100mm