MJH-19023-BeneHeart C Series Service Training V2.0 en

You might also like

Download as pptx, pdf, or txt
Download as pptx, pdf, or txt
You are on page 1of 54

BeneHeart C Series Service Training

PMLS Global Technical Support Department


Version: V2.0
Number: MJH-19023-BeneHeart C Series

© 2018 Mindray Confidential


Contents
Overview

Installation

Maintenance

Troubleshooting

Disassembly & Repair

Software Upgrade
2 © 2018 Mindray Confidential
AED Product Portfolio
Price
BeneHeart C series

D1 pro
C2
D1 pub
C1A

Performance

For public For professional

3 © 2018 Mindray Confidential


C Series Configuration
Without screen With screen

BeneHeart C1A BeneHeart C1A Fully-auto BeneHeart C2 BeneHeart C2 Fully-auto

7 〃 TFT Screen ○ ○ ● ●
Defibrillation mode Semi-auto Fully-auto Semi-auto Fully-auto
Shock button ● ○ ● ○
Switch to Adu/Ped Mode ● ● ● ●
Language selection Up to 3 languages Up to 3 languages Up to 3 languages Up to 3 languages
USB port for data output ● ● ● ●
Pre-connected Adult/Pediatric
● ● ● ●
Pads
Auto-ID for Adu/Ped Pads ● ● ● ●
Li-MnO2 Battery (disposable,
● ● ● ●
5-year)
CPR feedback Optional Optional Optional Optional
Wi-Fi for AED-Alert system Optional Optional Optional Optional
4G for AED-Alert system Optional Optional Optional Optional
4 © 2018 Mindray Confidential 4G data transfer and AED-Alert 2.0 system are only available in EU & AUS
C series vs. D1 pub
BeneHeart C series BeneHeart D1 pub

7 〃 TFT Screen Without / with screen Only with screen

Defibrillation mode Semi-auto / fully-auto Only semi-auto

Language selection Up to 3 languages Up to 2 languages

Switch to Adu/Ped Mode ● ●

USB port for data output ● ●

Pre-connected Adult/Pediatric Pads ● ●

Auto-ID for Adu/Ped Pads ● Optional

Battery Li-MnO2 battery (disposable, 5-year) Li-MnO2 battery (disposable, 4-year)

CPR feedback Optional Optional

Wi-Fi for AED-Alert system Optional Optional

4G for AED-Alert system Optional Optional


5 © 2018 Mindray Confidential
Accessories

Pre-connected Adult/Pediatric Li-MnO2 Battery Wall Bracket Wall Cabinet


Pads (5 years) (disposable, 5 years)

CPR Sensor Kit Backpack Rescue Kit Trainer Kit


6 © 2018 Mindray Confidential
Connected AEDs with IoT technology

Sensors Cloud server Application

4G

Self-test data Base station Cloud server Web browser

7 © 2018 Mindray Confidential


*Wi-Fi connection is available
Remote AED Management System AED-Alert™ 2.0

8 © 2018 Mindray Confidential


Contents
Overview

Installation

Maintenance

Troubleshooting

Disassembly & Repair

Software Upgrade
9 © 2018 Mindray Confidential
Overview

Model No. Factory Code S/N


BeneHeart C1A 0654 AF1-
BeneHeart C1A Fully Automatic 0654 AF3-
BeneHeart C2 0654 AE7-
BeneHeart C2 Fully Automatic 0654 AE9-

Note:
• For models with A, front cover is yellow.
• For models with Fully Automatic, front panel is without shock button.
• For models with C1, front panel is without LCD.
• For models with C2, front panel is with LCD.

10 © 2018 Mindray Confidential


Overview
Pads connector

Language switch

Adult/child mode switch

Pad expiration window

Shock button
Status indicator *only for semi-auto

BeneHeart C2

11 © 2018 Mindray Confidential


Overview
Network
connector
*optional for 4G

USB connector

CPR sensor port


*optional

12 © 2018 Mindray Confidential


Overview

125-000060-00 Adu/Ped Multifunction Electrode Pads


125-000061-00 Adu/Ped Multi Electrode Pads(5/BOX)
Expired Date (5 YEARS Validity period)

Pre-connected Adult/Pediatric
Pads (5 years) MR62

115-065054-00 Li-MnO2 Battery,12V,4200mAh,C&S series


Battery standby life:
5years: The equipment is powered by a new battery at 20 C± 5 C of ambient temperature, performing auto test every day,
equipment not in use, not sending self-test report
3years: The equipment is powered by a new battery at 20 C± 5 C of ambient temperature, performing auto test every day,
equipment not in use, sending self-test report every weak through the wireless network)
2years: The equipment is powered by a new battery at 20 C± 5 C of ambient temperature, performing auto test every day,
equipment not in use, sending self-test report every day through the wireless network)
Li-MnO2 Battery (disposable)

13 © 2018 Mindray Confidential


Contents
Overview

Installation

Maintenance

Troubleshooting

Disassembly & Repair

Software Upgrade
14 © 2018 Mindray Confidential
Installation Process Location
0. Wireless Survey Customer site

1. Unpacking and Checking

Dealer Office/
2.Configuration Change
AED Network Need to follow Branch Office
No wireless 1-2-3-4
3. User Test
4G module 0-1-2-3-4-5-6 or
0-1-2-3-6-4-5
4. Battery Loading Test
Wi-Fi module 0-1-2-3-6-4-5
Customer site
4G data transfer and AED-Alert 2.0 system are only 5. Network Test
available in EU & AUS.

6. Import Device in AED Alert Dealer Office

15 © 2018 Mindray Confidential


Installation  Wireless Survey- 4G Network Exploration
Option 1: Smart Phone + App "Cellular-Z” Option 2: AED + Cabinet + Laptop + AED tool

16 © 2018 Mindray Confidential


Installation  Wireless Survey- Wi-Fi Network Exploration
AED + Cabinet + Laptop + AED tool + AED Alert

17 © 2018 Mindray Confidential


Installation  Wireless Survey- Wi-Fi Network Exploration

 Confirm Self-test report in Alert

 Visit https://aedalert.mindray.com
Login with Agent Account
1. Enter Device Details Option
2. Add device for this SN
3. Check Network Signal in Self-test report
18 © 2018 Mindray Confidential
Installation
 Unpacking and Checking
Before unpacking, examine the packing case carefully for signs of
damage. If any damage is detected, contact the carrier or the
manufacturer. If the packing case is intact, open the package and
remove the equipment and accessories carefully. Check all materials
against the packing list and check for any mechanical damage. If you
have any question, please contact us.

19 © 2018 Mindray Confidential


Installation

Note: Pads are pre-connected.

20 © 2018 Mindray Confidential


Installation
 Modify Configuration — AED Tool Installation and Use Guide

Basic Operations
1. After the device is connected to the AED Tool, enter the
Configuration page, click Read Device Configuration, and the
prompt “Reading the configuration file successfully!” appears.
2. Close the above prompt box, edit System Time, Language,
Shock Series, WLAN Setup, and other items, click Write Device
Configuration, and the prompt “Writing successfully! Effective
after the device is restarted” appears.
3. Restart the AED device and the written configurations takes effect.

21 © 2018 Mindray Confidential


Installation
 User Test — AED Tool Installation and Use Guide

1. With the device lip opened, enter the User Test page.
2. Click Start User Test, the device starts the user test,
and you should perform user test followed the voice
and text prompts.
3. After the test is completed, click Get Test Result to
read the test results.

Other ways to receive voice test result

22 © 2018 Mindray Confidential


Installation
 Battery Loading Test
Confirm the external defibrillator, the buttons, the horn, the
pads and the batteries can work normally. Follow this
procedure to perform the test:
1. Close the upper cover of the external defibrillator.
2. After removing the batteries for 3 minutes, re-install the
batteries to the battery compartment of the external
defibrillator and enter the battery loading self-test mode.
3. Perform the auto test, audio test and button test according to
the voice prompts of the external defibrillator.
4. Test whether the device is abnormal according to the voice test
results. If any item fails, the status indicator will flash red when
the device is turned off.
23 © 2018 Mindray Confidential
4G module
Installation
 Network Test — SN not imported in Alert
AED + Cabinet + Laptop + AED tool

4G Wi-Fi

Wi-Fi module

 Network test is after User test


 After User test, put AED in Cabinet
 Wait till Status indicator flash normal
24 © 2018 Mindray Confidential
Installation
 Network Test — SN already imported in Alert

 Network test is after User test


 After User test, put AED in Cabinet
 Wait till Status indicator flash normal

 Visit https://aedalert.mindray.com
Login with Agent Account
1. Enter Device Details Option
2. Search the SN
3. Check Network Signal in Self-test report
25 © 2018 Mindray Confidential
Installation
 Import Device in AED AlertTM 2.0
 Apply Agent Account with Mindray HQ (Only first time)
 Visit https://aedalert.mindray.com Login with Agent Account
 Modify Personal Info.
 Press Mindray logo to enter Device List

26 © 2018 Mindray Confidential


Installation
 Import Device in AED AlertTM 2.0
 Enter Permission Mgmt. -> User Mgmt. -> Create User
 Create Device Admin Account

27 © 2018 Mindray Confidential


Installation
 Import Device in AED AlertTM 2.0
 Enter Device Mgmt. -> Device List
 Press Add Device to import AED (Recommended)
 Associate Device with Device Admin

28 © 2018 Mindray Confidential


Installation
 Import Device in AED AlertTM 2.0
 Enter Device Mgmt. -> Device Details
 Check All Device Status
 Check Self-test Report is received

29 © 2018 Mindray Confidential


Contents
Overview

Installation

Maintenance

Troubleshooting

Disassembly & Repair

Software Upgrade
30 © 2018 Mindray Confidential
Maintenance
 Performing Maintenance

31 © 2018 Mindray Confidential


Maintenance
 Recommend Frequency

32 © 2018 Mindray Confidential


Maintenance
 Cleaning

33 © 2018 Mindray Confidential


Contents
Overview

Installation

Maintenance

Troubleshooting

Disassembly & Repair

Software Upgrade
34 © 2018 Mindray Confidential
Troubleshooting
 Run test & getting results

Battery loading test AED tool AED Alert


/ User test (User test) (4G/WiFi module)
• Receive test results
• Start manually • Start by tool option
• Check Fault ,
• Test results Voice • Test results shown
Warning & Self-test
report on tool
report

35 © 2018 Mindray Confidential


Troubleshooting
 Battery loading test / User test

36 © 2018 Mindray Confidential


Troubleshooting
 AED tool (User test)

37 © 2018 Mindray Confidential


Troubleshooting
 AED Alert (Fault & Warning & Self-test report)

38 © 2018 Mindray Confidential


Contents
Overview

Installation

Maintenance

Troubleshooting

Disassembly & Repair

Software Upgrade
39 © 2018 Mindray Confidential
Disassembly & Repair
 System Structure

40 © 2018 Mindray Confidential


Disassembly & Repair
 Safety

 Once you power on the BeneHeart C Series, no matter you charge or not,
there is high voltage inside the machine. You must discharge the capacity
before you touch any of parts inside.
41 © 2018 Mindray Confidential
Disassembly & Repair
 Safety
Discharge Using the Discharge Fixture. If you don’t have Discharge Fixture, take out the
battery and wait for 2 hours before you open the device.

42 © 2018 Mindray Confidential


Disassembly & Repair
 Rear housing assembly

43 © 2018 Mindray Confidential


Disassembly & Repair
 Front housing assembly

44 © 2018 Mindray Confidential


Disassembly & Repair
 Main Board

051-003470-00 without
the interfaces in red cycle

Order Number Part Number Part Description Compatibility Remarks

115-064215-00 051-003312-00 0654 main board(4G/WIFI)FRU must remark SN


must remark SN not support
115-064217-00 051-003470-00 0654 main board(STD)FRU
LCD/WIFI/NFC/4G/CPR
45 © 2018 Mindray Confidential
Disassembly & Repair
 Modify Main Board Configuration with AED tool
 Not for customer, only for main board repair
 Need Advanced installation SN of AED tool
 To modify Device SN
 To modify Semi-Auto/Fully-Auto
 To modify with/without LCD
 To modify with/without 4G/WiFi module

Warning: Main Board Configuration will change the device function. Wrong configuration for
device will cause serious consequences in rescue operations. After mainboard replacement,
must run User test to confirm.
46 © 2018 Mindray Confidential
Contents
Overview

Installation

Maintenance

Troubleshooting

Disassembly & Repair

Software Upgrade
47 © 2018 Mindray Confidential
Software Upgrade
 How to check software version
 Open AED tool Software
 Connect to AED device
 Enter the Device Info. page and read the
device information

48 © 2018 Mindray Confidential


Software Upgrade
 Preparation

Recommend:
Put only one Upgrade Package in folder, because only one pkg can be upgraded in one time.
Otherwise, operator couldn’t judge which one is upgraded in the last time.

49 © 2018 Mindray Confidential


Software Upgrade
 Upgrade process
 With or Without LCD
1. Unplug the battery when the cover of the device is closed.
2. Insert the USB storage into the device.
3. Insert the battery when the cover of the device is closed.
4. Wait until the device indicator is on, which indicates that the device is in upgrade mode.
5. Wait for 1-2 minutes.
1) With power upgrade package, the device will enter the AED mode after the upgrade
2) Without power upgrade package,
succeed: beep sound reminder every 5s & indicator flash green every 5s
failed: beep sound reminder every 2s & indicator flash red every 2s

 With LCD have upgrade info display

50 © 2018 Mindray Confidential


FAQ

 Q1 : Which area can launch 4G AED and AED-Alert 2.0 system ?


 A1 : 4G data transfer and AED-Alert 2.0 system are only available in EU & AUS
 Q2 : How to acquire AED Alert Agent or Branch Office Account ?
 A2 : Apply account by CS to HQ TS
 Q3 : Does BeneHeart C Series AED support hardware upgrade ?
 A3 : No, there is no hardware upgrade package
 Q4 : If the battery standby life doesn’t fit the years in the manual, how to do ?
 A4 : Export the device info from AED, and confirm how many times it has been used,
or if the wireless signal strength is low in history self-test report
 Q5 : After modify Main Board Configuration with AED tool , what should do ?
 A5 : Must run User test to confirm the device function
51 © 2018 Mindray Confidential
Version Information
Version Number Editor Date Description

1.0 Matthew Chang Sep-2019 First edition.

2.0 Matthew Chang Mar-2020 1, Modified AED Alert system site as


operation manual;
2, AED-Alert 2.0 system is available in EU
& AUS;

52 © 2018 Mindray Confidential


Review Information
Version Number Reviewed by Review Date Revision Details

1.0 Sam Shen Sep-2019

2.0 Sam Shen Mar-2020

53 © 2018 Mindray Confidential


Thank you!

54 © 2018 Mindray Confidential

You might also like