NL EN 81standards
Habib Srour
Purpose
NL EN81-7X
NL EN81-4X
NL EN81-2X NL EN81-3X Particular
Special lift for NL EN81-5X NL EN81-8X
Lifts for transport Lifts for transport applications
transport of person Evaluations Existing Lifts
of persons , goods of goods only persons and
and goods
goods
50: 2015
1: 2011 70: 2015 80: 2011
40: 2015 Examinations,
3(0): 2011 Accessibility of Improvement of
- Electric Lifts Stairlift & Inclined Calculations &
Service Lifts Persons with Safety of Existing
lifting platform Tests of Lift
Impaired Mobility Lifts
Components
82: 2015
31: 2015 41: 2015
2: 2011 Accessibility
Accessible Goods Vertical Lifting
- Hydraulic Litfs Improvement of
Only Lifts Platforms
Existing Lifts
20: 2015
Passenger and
goods passenger
lifts
21: 2015
Passenger lifts in
existing buildings
22: 2015
Passenger lifts,
inclined
New Standard Structure
0- Introduction
1- Scope
2- Normative references
3- Terms and definitions
4- List of significant hazards
5- Safety Requirements
6- Verification
7- Information for use
Annexes: Informative, Normative
Amendments related to NL
EC Type Examination Certificate for the lift as
a set
5.4- Car,
counterweight and
balancing weight
Mechanical (1)
5.5- Suspension means,
compensation means
and related protection
means
5.8- Buffers
5.10- Electric
installations and
appliances
0.035 * V2
Screen
between two
lifts is
measured
from handrail
Ladder Requirements
5.4- Overspeed
governors
5.5- Buffers
NL EN81-50: Tests of equipment
5.6- Safety circuits
containing electronic
components
5.3- Counterweight or
balancing weight in a
separate well
5.8- Apron
Requirements Sign
Reduced Bottom Clearance
Requirements Sign
Mechanisms for reduced
headroom and pit
NL EN 81-70
Accessibility for persons with
impaired mobility
NL EN81-70
Accessibility to lifts for persons including
persons with disability
In case a user of a
wheelchair cannot turn
it around, a mirror
shall be provided.
Rated load:
◦ Minimum 115kg for person users and
◦ Minimum 250kg/m2 for wheel chair users
Minimum Clearance Dimensions
◦ affixed to a building
structure
Overload required