Professional Documents
Culture Documents
Azad Progress
Azad Progress
mdazadalam825412@gmail
Father’s Name MD MANIRUDDIN ANSARI Email .com
1. PRADEEP KUMAR
2. MD AHMAD RAZA
Project Tittle OXYGEN CONCENTRATOR Project Fellows 3. NIRANJAN KUMAR
4. SAHRUKH KHAN
Introduction
An oxygen concentrator is a medical device used to
deliver oxygen to individuals with respiratory
conditions that result in low levels of oxygen in
their blood. It works by taking in ambient air, which
contains about 21% oxygen, and filtering out
nitrogen and other gases to provide a concentrated
stream of oxygen, typically at concentrations
between 90-95%. Oxygen concentrators are vital for
patients requiring long-term oxygen therapy and can
significantly improve the quality of life for
individuals with chronic respiratory conditions.
Objectives of the Project
Mayo Clinic
Home Oxygen Therapy
An overview of home oxygen therapy options, including guidelines for using oxygen
concentrators.
Manufacturers and Technical Manuals
Philips Respironics
"SimplyGo Portable Oxygen Concentrator User Manual"
Work Completed
Design and Prototyping
Completed initial design and 3D modeling of the oxygen concentrator.
Developed and tested the first prototype, focusing on size, weight, and
portability.
Selected materials for the compressor and molecular sieve components.
Technical Development
Integrated a high-efficiency compressor capable of delivering consistent
oxygen flow.
Implemented zeolite molecular sieves for effective nitrogen adsorption.
Developed a control system with adjustable flow rates and user interface.
Connectivity and Monitoring
Integrated wireless modules for remote monitoring capabilities.
Developed a companion mobile app for patient and clinician use, enabling
real-time monitoring and adjustments.
Testing and Validation
Conducted initial lab tests to validate oxygen purity levels and flow rates.
Performed noise level assessments to ensure compliance with standards.
Results and Discussions
• Prototype Testing
• Performance Metrics: The second prototype was tested with a group
of 50 patients over a period of one month. Key performance metrics
included:
• Oxygen Purity: Consistently achieved 92-94% oxygen concentration.
• Battery Life: Average battery life was 6 hours under continuous operation.
• Noise Level: Measured at 42 decibels, which is quieter than many existing
models.
• Heat Generation: Surface temperature remained below 40°C during
continuous use.
• Performance Analysis
• Oxygen Purity: The oxygen concentrator met the target oxygen purity
levels (92-94%), which is within the acceptable range for medical use.
The consistent performance indicates reliable operation of the zeolite
molecular sieves and compressor system.
•
Further Work to be carried Out