PRAESENSA

UL 2572
MASS NOTIFICATION
SYSTEMS
UL 2572 Mass Notification Systems
Introduction
 MKP and HW and SW engineering is working on certifying PRAESENSA for UL 2572

 Certification is expected in 2022

 Configuration pages have already UL 2572 functionalities

 These new configuration items may be confusing when not explained.

2 Internal | Building Technologies | BT-CO/MKA1.22 | 2021-07-15


© Bosch Security Systems B.V. 2021. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
UL 2572 Mass Notification Systems
Some abbreviations and terms used in UL2572 standard
 MNS Mass Notification Systems
 AHJ Authorities Having Jurisdiction
 ACU Autonomous Control Unit
 LOC Local Operating Console
 ECCU Emergency Communication Control Unit
 ECS Emergency Communication System
 NAC Notification appliance Circuit
 UL Underwriters Laboratory
 ULLD Underwriters Laboratory Listing Document

 Trouble signal Visual or audible signal indicating a fault condition.

3 Internal | Building Technologies | BT-CO/MKA1.22 | 2021-07-15


© Bosch Security Systems B.V. 2021. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
UL 2572 MNS

CONFIGURATION PAGES
UL 2572 Mass Notification Systems
Opening screen: Language selection for configuration pages
 To select UL language
 Select: English (UL 2575)

 Language differences English – UL English (Web pages)

 Fault Trouble
 Mains supply AC Power supply
 Output overload Amplifier overload

 Important:
 If you select standard English, all UL functions are still available
also if you select another language than English (UL 2572).

5 Internal | Building Technologies | BT-CO/MKA1.22 | 2021-07-15


© Bosch Security Systems B.V. 2021. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
UL 2572 MNS

CONFIGURATION
SETTINGS
UL 2572 Mass Notification Systems
Device options: New setting for all Praesensa devices
 Emergency relevant (Device general setting)
 Setting per device
‒ Is the device necessary for an emergency: Yes/No
‒ System controller is always Emergency relevant

‒ Yes: The device is important for an emergency situation ‒ No: The device is not important for an emergency
‒ Any fault in the device: situation
‒ Trouble (Fault) alarm triggered: Sounder/indicator ‒ Any fault in the device:
(Audible/visual indicator) ‒ No Trouble (Fault) alarm triggered
‒ Fault will be shown on CST Fault log display
‒ Fault will be shown on CST display
(Important for firemen)
‒ Trouble (Fault) ack/reset indicated on extension (Not important for firemen)

‒ Entry in the logging ‒ No Trouble (Fault) ack/reset indicated


‒ Entry in the logging.

12 Internal | Building Technologies | BT-CO/MKA1.22 | 2021-07-15


© Bosch Security Systems B.V. 2021. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
UL 2572 Mass Notification Systems
Device options: New setting for all Praesensa devices
 Emergency relevant

13 Internal | Building Technologies | BT-CO/MKA1.22 | 2021-07-15


© Bosch Security Systems B.V. 2021. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
UL 2572 MNS

MULTIFUNCTION POWER
SUPPLY
UL 2572 Mass Notification Systems
Device options: MPS3 Control inputs
 AC power supply trouble: External (New text)

 Power save mode (New)

 Acknowledge and/or reset


 Option added (New)

15 Internal | Building Technologies | BT-CO/MKA1.22 | 2021-07-15


© Bosch Security Systems B.V. 2021. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
UL 2572 Mass Notification Systems
Action definition: MPS3 Control inputs
 AC power supply trouble: External (New text)
 A fault is reported
 The system goes in the Backup power mode

 Power save mode (New)


 A fault is NOT reported
 The system goes in the Backup power mode

16 Internal | Building Technologies | BT-CO/MKA1.22 | 2021-07-15


© Bosch Security Systems B.V. 2021. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
UL 2572 Mass Notification Systems
Action definition: MPS3 Control inputs
 Acknowledge and/or reset
 Type
‒ Trouble (New text)
‒ Emergency
‒ Fault and Emergency (New)

 Ack/reset
‒ Acknowledge
‒ Reset
‒ Ack and Reset

 UL requires one button to silence all buzzer in the system


 Ack/reset for fault and emergency.

17 Internal | Building Technologies | BT-CO/MKA1.22 | 2021-07-15


© Bosch Security Systems B.V. 2021. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
UL 2572 Mass Notification Systems
Device options: MPS3 Control outputs
 Trouble sounder (New text)
 Trouble indicator (New text)
 Alarm sounder (New text)
 Alarm indicator (New text)
 System trouble indicator (New text)
 Power fault indicator (New).

18 Internal | Building Technologies | BT-CO/MKA1.22 | 2021-07-15


© Bosch Security Systems B.V. 2021. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
UL 2572 Mass Notification Systems
Action definition: MPS3 Control outputs
 Trouble sounder
 Trouble indicator
 If grace time is set (on system settings page):
‒ Indicate mains power fault after grace time
‒ Default off

 Power fault indicator


 Mains power fault (Default)
‒ Delayed CO if grace time is set
 Battery backup fault

 Grace time set on System settings page


‒ Default off (Up to 8 hours).

19 Internal | Building Technologies | BT-CO/MKA1.22 | 2021-07-15


© Bosch Security Systems B.V. 2021. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
UL 2572 MNS

CALL STATION
UL 2572 Mass Notification Systems
Device options: Call station: Settings
 Settings (New)
 Call station setting

 General
 Class
‒ Normal
‒ Emergency
‒ Mass notification (New)
‒ Transfer of control functions

 Emergency relevant (New).

21 Internal | Building Technologies | BT-CO/MKA1.22 | 2021-07-15


© Bosch Security Systems B.V. 2021. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
UL 2572 Mass Notification Systems
Device options: Call station: Emergency group
 Emergency group (New)
 Mass notification CSTs can be linked in an Emergency group
‒ Available function: Transfer of control
‒ Max. 1 emergency group
‒ Max. 20 emergency CST in an emergency group

 In the emergency group one CST is default in control


‒ Other CSTs have no control
‒ Other CSTs will follow the behavior of the CST in control

 Other CSTs can request control


‒ The CST in control can grant or deny the request
‒ After a pre-set timeout a request for control is automatically granted

 CSTs can be assigned that can overrule control requests


‒ These CSTs can always have immediate access, overruling others.
22 Internal | Building Technologies | BT-CO/MKA1.22 | 2021-07-15
© Bosch Security Systems B.V. 2021. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
UL 2572 Mass Notification Systems
Device options: Call station: Emergency group
 Emergency group (New)
 Assign Mass notification CSTs to an emergency group

 When an Mass notification CST is assigned to an emergency CST group


‒ Emergency CST group name is added to the CST name
‒ Transfer of control is now possible.
23 Internal | Building Technologies | BT-CO/MKA1.22 | 2021-07-15
© Bosch Security Systems B.V. 2021. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
UL 2572 Mass Notification Systems
Additional information: Transfer of control functions
 Transfer of control functions buttons on the CST  Control indication (Who is in control)
extension  Indication on CST in control
 Button can be used for Overrule control request
 Transfer of control locations (if assigned)
 Visible on CST display (Sub-menu).  Request control
 For CSTs that are not in control but would like to take over
control (1st come, 1st servered)
 Grant control
 For CST in control to grant control to CST that requests
control
 Deny control
 For CST in control to deny control to CST that requests
control

 Grant control timeout


 Automatic grant of control after timeout
24 Internal | Building Technologies | BT-CO/MKA1.22 | 2021-07-15
© Bosch Security Systems B.V. 2021. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
UL 2572 Mass Notification Systems
Additional information: Transfer of control
 One CST is in control
 Other CSTs can request control
 Calls, started on the CST in control, are visible on the other CSTs in the group (E.g. selected zones)
 If CST extension function are equal
 Calls, started on one CST, can be stopped on another CST if it takes over control

In control Not in control Control locations.

Request Control Request Control Request Control


Control Control Control

Grant Deny Grant Deny Grant Deny


Control Control Control Control Control Control

25 Internal | Building Technologies | BT-CO/MKA1.22 | 2021-07-15


© Bosch Security Systems B.V. 2021. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
UL 2572 MNS

CALL STATION
EXTENSION
UL 2572 Mass Notification Systems
Device options: Call station extension
 Transfer of control (New)
 Function only available when CSTs are part of an
emergency group
 Function consists of 4 option: 4 Buttons required
‒ Control indicator
‒ Request control
‒ Grant
‒ Deny.

27 Internal | Building Technologies | BT-CO/MKA1.22 | 2021-07-15


© Bosch Security Systems B.V. 2021. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
UL 2572 Mass Notification Systems
Action definition: Call station extension
 Transfer of control
 Control indicator
‒ Overrule control request
 Request control
 Grant
 Deny.

28 Internal | Building Technologies | BT-CO/MKA1.22 | 2021-07-15


© Bosch Security Systems B.V. 2021. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
UL 2572 Mass Notification Systems
Device options: Call station extension
 Acknowledge and/or reset (Changed).

29 Internal | Building Technologies | BT-CO/MKA1.22 | 2021-07-15


© Bosch Security Systems B.V. 2021. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
UL 2572 Mass Notification Systems
Action definition: Call station extension
 Acknowledge and/or reset
 Type
‒ Trouble (New text)
‒ Emergency
‒ Fault and Emergency (New)

 Ack/reset
‒ Acknowledge
‒ Reset
‒ Ack and Reset

 UL requires one button to silence all buzzers in the system


 Ack and Reset for Fault and Emergency
‒ When Acknowledge for Fault and Emergency is pressed, when no Trouble or
Emergency is present, the buzzer will sound.

30 Internal | Building Technologies | BT-CO/MKA1.22 | 2021-07-15


© Bosch Security Systems B.V. 2021. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
UL 2572 Mass Notification Systems
Device options: Call station extension
 Make announcement with zone selection (New)

 To start an announcement in zones or zone groups


 Multiple buttons can be configured
‒ Each button can have a different pre-recorded message

 Zones or zone groups have to be selected, then select the


required message

 Zones can be added to a running call


 Zones cannot be removed from a running call
‒ Call has to be stopped.

31 Internal | Building Technologies | BT-CO/MKA1.22 | 2021-07-15


© Bosch Security Systems B.V. 2021. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
UL 2572 Mass Notification Systems
Action definition: Call station extension
 Make announcement with zone selection

 Operation
 Toggle – abort on switch off
 Toggle – finish on switch off

 Call definition
 Call definition with message(s) only
 Call definition with live speech is possible but not recommended
‒ No Momentary operation possible.

32 Internal | Building Technologies | BT-CO/MKA1.22 | 2021-07-15


© Bosch Security Systems B.V. 2021. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
UL 2572 MNS

SYSTEM SETTINGS
UL 2572 Mass Notification Systems
System settings
 Call station operator language
 English (UL 2572) (New).

34 Internal | Building Technologies | BT-CO/MKA1.22 | 2021-07-15


© Bosch Security Systems B.V. 2021. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
UL 2572 Mass Notification Systems
System settings
 UL amplifier mode (New in fw 1.2)
 the amplifiers comply to the requirements of UL with regards to
temperature limitations
‒ Amplifier fans will always run at full power (Noisy)

 When disabled, the amplifiers run in the EN54 mode.

35 Internal | Building Technologies | BT-CO/MKA1.22 | 2021-07-15


© Bosch Security Systems B.V. 2021. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
UL 2572 Mass Notification Systems
System settings
 Mains supply fault
(Backup power mode: Report mains supply fault)

 Grace time to report mains fault on control outputs


‒ Default: Off
‒ Up to 8 hours in steps of 1 hour.

36 Internal | Building Technologies | BT-CO/MKA1.22 | 2021-07-15


© Bosch Security Systems B.V. 2021. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
UL 2572 Mass Notification Systems
System settings
 Alarm buzzer (Fault mode)
 Reactivate silenced fault and emergency alarm buzzer
‒ Default: Off
‒ Up to 24 hours in steps of 1 hour.

37 Internal | Building Technologies | BT-CO/MKA1.22 | 2021-07-15


© Bosch Security Systems B.V. 2021. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
UL 2572 Mass Notification Systems
System settings
 Configuration software (New)
 Automatic logout after inactivity
‒ Default 10 minutes
‒ Between 5 and 30 minutes in steps of 1 minute.

38 Internal | Building Technologies | BT-CO/MKA1.22 | 2021-07-15


© Bosch Security Systems B.V. 2021. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
UL 2572 MNS

CALL DEFINITION
UL 2572 Mass Notification Systems
Call definition
 Priority
 Call with normal prio: <224

 Call with emergency prio: >223


‒ Alarm: Emergency (default)
‒ Emergency prio call -> emergency state
‒ Red zone indication on all CSTs
‒ Activates the alarm buzzers on CSTs & CO
‒ Emergency Ack/reset to end emergency state

‒ Alarm: None
‒ Emergency prio call -> no emergency state
‒ Red zone indication on all CSTs
‒ No alarm buzzer on CSTs & CO
‒ No emergency Ack/reset.

40 Internal | Building Technologies | BT-CO/MKA1.22 | 2021-07-15


© Bosch Security Systems B.V. 2021. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
UL 2572 MNS

CST & CST DISPLAY FOR


UL2572
UL 2572 Mass Notification Systems
CST general
 LED ring around microphone stem:
 Green blinking : Chime / message active (business call)
 Green : Microphone active (business call)
 Red blinking : Chime / message active (emergency call)
 Red : Microphone active (emergency call)

 Power indicator LED


 Green : Power on
 Green blinking : Identification mode

 System fault LED


 Yellow : System fault
 Yellow blinking : Identification mode.

42 Internal | Building Technologies | BT-CO/MKA1.22 | 2021-07-15


© Bosch Security Systems B.V. 2021. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
UL 2572 Mass Notification Systems
Display: Mass Notification
 4.3" Full color touch screen
 MNS lay out
 LED-ring
 PTT push button.

43 Internal | Building Technologies | BT-CO/MKA1.22 | 2021-07-15


© Bosch Security Systems B.V. 2021. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
F
e UL 2572 Mass Notification Systems
a Display: Mass Notification
t  Fault indications
u  On call station
r ‒ Power
‒ System fault
e
s  On display
‒ General fault
‒ Battery fault
‒ Mains fault.

44 Internal | Building Technologies | BT-CO/MKA1.22 | 2021-07-15


© Bosch Security Systems B.V. 2021. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
UL 2572 Mass Notification Systems
Display: Mass Notification
 Navigation tiles
 Fault log
‒ Acknowledge button
‒ Reset button
 Control locations
 Info

 Call progress indication


 Please wait : Start tone active
 Talk now : microphone active
 Please wait : End tone active
 Call completed : Call ended.

45 Internal | Building Technologies | BT-CO/MKA1.22 | 2021-07-15


© Bosch Security Systems B.V. 2021. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
UL 2572 Mass Notification Systems
Logging server application, language selection UL
 During installation of the logging server
 Select Options
 Select Application language: English UL2572.

46 Internal | Building Technologies | BT-CO/MKA1.22 | 2021-07-15


© Bosch Security Systems B.V. 2021. All rights reserved, also regarding any disposal, exploitation, reproduction, editing, distribution, as well as in the event of applications for industrial property rights.
UL 2572 Mass Notification Systems
Logging viewer application, language selection UL
 During installation of the logging viewer
 Select Options
 Select Application language: English UL2572.