Product specifications - Intuitive use.

The Keeper permanently senses voltage and current at distance, - Always alert, always looking after you.
alerting the user before entering a dangerous area. The Keeper not only
- Robust and lightweight design - 30 g.
indicates the hazard but also indicates the direction and distance of the
hazard. By using the Keeper, you minimize: - Directional and proximity alerts.
- Adjustable sensitivity, according to the user’s expertise.
• The electrical risk associated with sources of any
voltage level, such as power lines, cables or downed - High capacity rechargeable Li-ion battery, 3.7 V./350 mAh.
installations in storm zones.
- Self-test function, TRUE TEST.
• The risk of electric arc, associated with high current
sources, such as panels, disconnectors and industrial
installations.
EC 61243: LIVE WORKING – VOLTAGE DETECTORS – Part
The operation is very simple and intuitive, it is a permanent watch 6: Guidelines on non-contact voltage detectors
device, which makes it extremely safe, since it does not need to be (NCVD) for use at nominal voltages above 1 kV a.c.
turned on to operate, the Keeper is always alert, taking care of you.
F3283/F3283M Standard Specification for the Manufacturing of
The Keeper mounted on the visor of the safety helmet, alerts the High-Voltage Proximity Alarm to be used for the
operator in real time through lights and sounds. The location on the Detection of Overhead High Voltage Alternating Current (AC)
helmet allows the operator to use peripheral vision, without having to
look at it.
The Keeper detects 360 dangers around the user, and will
not only indicate the danger, but will also gives the direction and
approximate distance of the threat.
The Keeper has 4 modes of use
according to the user’s expertise: Rookie, Standard, Professional and
Professional Plus.
Keeper components
Keeper Technology

Microcontroller
Low power high performance Microcontroller – 64 MHz
In-Circuit Serial Programming™ (ICSP™)
10-bit ADC with ADC2

Magnetometer
3 Axis Magentic sensor
18bits ADC - High speed sampling rate 1000Hz
High resolution 0,25 mG

Indications
1 mm. Intelligent RGB LEDS, Hy Intensity 720 mcd, 1.6 Millons colors
Magnetic buzzer, Sound pressure level 87 dBA

SMT Micro Technology


User mode selection x4

The Keeper counts with four different sensibility adjustments for different user profile:

- Rookie -
No knowledge of electrical hazards and arc flash
risks.
- Standard -
Basic knowledge of electrical hazards and arc flash risks.

- Professional -
Advanced knowledge of electrical hazards and arc flash
risks, knows the safety distances based on the voltage
involved.

- Professional PLUS -
Same as professional mode, but intended for on site work.
Distance voltage detector, Red INDICATION

VOLTS New fully digital threshold calibration


Directional voltage indicator,
Front, Left, rigth

AMPS Distance currente detector, Green INDICATION

3 axis magnetometer
Distance of activation

Rookie
Std
Pro

X [ft.]
Operation Modes
Power On Sleep Mode
After 60” with no voltage or current indicators
To power the Keeper on, press and release
on, the Keeper enters SLEEP mode.
the Main button. The Keeper will execute an
Even though the Keeper is in low consumption
AUTO-TEST routine.
mode, the Keeper stays ALERT and ON.
If the test is satisfactory, the sensibility
One short beep will
calibration for voltage and current will
indicate the Keeper entering SLEEP mode.
be displayed.
If the test is not satisfactory, the Keeper will
enter ERROR mode.

Power Off Current Detection

Pressing both MAIN and AUX buttons will


lead to POWER-OFF. A quick sequence of
blue light will indicate the Keeper successfully Keep pressing the AUX button to
entered POWER-OFF mode. enter
Only use this mode for storage or traveling. CURRENT DETECTION mode
This mode does not keep you safe. Use it at
your own risk.
Sensibility selection
To enter user mode selection menu, connect the Keeper to a power source through the USB-C cable. A blue blinking led will
indicate that the Keeper is charging.

Press the MAIN button to enter user selection mode, first select the voltage mode, cycling through the options by pressing the
MAIN button, and waiting 5” to confirmthe level. Repeat the steps for current mode.
Press

Rookie Standard Professional Professional Plus*

* To set the threshold level, press the MAIN button when


voltage/current detection is present. Wait for a confirmation beep.
A pink led will indicate that the threshold has been correctly set.
Press the
MAIN button again to reset the threshold to original values.
Auxiliary modes
To enter auxiliary modes, keep pressing MAIN button for three TEST cycles. Once in
auxiliary mode, press AUX button to cycle the different modes.
To exit, press MAIN button again

Press & hold MAIN to enter Press AUX to cycle Press MAIN to exit
auxiliary mode

3 x Auxiliary modes

Lantern SOS Beacon+


Error mode
After pressing the Main button. The Keeper will execute an AUTO-TEST
routine.
If the test is satisfactory, the sensibility calibration for voltage and current
will be displayed.
If the test is not satisfactory, the Keeper will enter ERROR mode.
The center led will indicate the error code

Yellow Blinking - battery Low


Red blinking - Very Low battery

1 Red Blink - Left antena error


2 Red Blinks - Right antena error
3 Red Blinks - Magnetometer error