Centiel

Swiss technology company

centiel.com 1
Who is Centiel?
Our team

Concurrently young and highly experienced UPS designer and manufacturer


Centiel’s long-standing experience in the UPS sector comes from:

Our team of experts

Mr. Filippo Marbach, Founder and CEO Mr. Gerardo Lecuona, Co-Founder and Global
Sales Director
Inventor of the first transformerless (1996)
and first modular UPS (2000) Previous Technology Director of ABB’s UPS
Division
Previous Co-founder, CEO and COO of
Newave (ABB since 2012) Electronics Engineer with embedded SW
design and Business Administration
specialization

Board management formed by leaders coming from Highly skilled engineers working in the UPS industry Specialized and well trained production and
the UPS industry for several years administration personnel
Centiel’s global presence

More than
40 countries
64 partners
Headquarter (Switzerland)
Subsidiaries
Partners

centiel.com 3
Customers & Projects
Protecting power in all different verticals

Banking Telecommunications Medical and pharma Automotive / Railway

Education Food&Beverage/Industrial IT Commerce

centiel.com 4
Telecom, transportation, banking

National Airforce
Chile

1.98 MW
30 x 50 kW
24 x 20 kW

1.44 MW
14x60kW
10x60kW
1.25 MW
5 x 60 kW
10 x 60 kW
5 x 25kW

centiel.com 5
Datacenter

Leading Datacenter and


Colocation facilities (UK)
Largest data centre in the
Czech Republic

2.28 MW  15 x 60kW 4.8 MW installed


12 x 60kW 2x2.4 MW  2 x (4 x 600 kW)
6 x 60kW
2x(3x50)kW

centiel.com 6
Food & beverage, Electricity

The largest electricity


Leading beverage
provider in Czech Republic
manufacturer - Chile

1.4 MW installed
(28 x 50 kW)

1.2 MW installed

20 x 60 kW
LiFePOwer
10 min @750kW

centiel.com 7
Industrial

State-owned corporation in the


petroleum industry in Brazil
900 kW
12 x 25 kW
10 x 60 kW

centiel.com 8
CumulusPower™ – (19” Universal Rack)

centiel.com 9
Centiel’s portfolio
UPS and batteries

UPS BATTERIES UPS+BATTERIES


SINGLE-PHASE STANDALONE MODULAR LITHIUM LITHIUM
EssentialPower™ PremiumTower™ CumulusPower™ LiFePower CumulusLiFe
Up to 7.5MW Up to 3.6MW

1:1 3:1 PT 400V PT 480V PT Medical Sp. CP 400V CP 480V LIB 20-100Ah IM 10-25kW
1-20kVA 10-20kVA 10-250kW 60kW 80-250kW 10-600kW 60-600kW 512, 614.4V LIB 12Ah, 384V

centiel.com 10
CumulusPower™
The 4th Generation
of Modular UPS

centiel.com 11
Availability as a metric
The higher the Availability, the lower the Downtime

x 100%

Availability of 99.99% = (4nines)


Availability levels Vs Downtime p/year
What is the downtime in 1 year? 99.99% (“four nines“) 52.6 minutes
Hours in a year = 8760 99.999% ("five nines") 5.26 minutes
Downtime = 8760 x (100% - 99.99%) 99.9999% ("six nines") 31.56 seconds
Downtime = 0.876 hours 99.99999% ("seven nines") 3.16 seconds
Downtime = 52.6 minutes
99.999999% ("eight nines") 315.58 milliseconds
99.9999999% ("nine nines") 31.56 milliseconds

centiel.com 12
centiel.com 13
How is Centiel’s technology different?
DARA (Distributed Active-Redundant Architecture)

Standalone Architecture Typical Modular Architecture DARA Modular Architecture


Common system blocks = Single points of failure

99.9999999 availability
Efficiency on every level

Module UPS Frame Multi-frame Complete system


The UPS module
Why is it the smartest?

Smart battery booster


Back-feed
Bypass
protection The DC charger is independent from the rectifier
- Safe battery tests
Back-feed Rectifier Output
Mains
protection
DC-DC bus
Inverter
relay Load
- High charging currents
- Flexible battery blocks
Battery
relay
- Common or separate batteries
Battery Multi processor
Display control logic

Actively monitored fans


Load: 100 kW

Charger
Voltage: 230V

The fans speed are constantly monitored


- Anticipate unexpected malfunctioning
- Replacement only when needed (<TCO)

Integrated back-feed protection


Every module includes - Reduced system cost
• Static bypass - Increased safety for service personnel
• Power unit
working on the UPS incoming supply
• Control logic
• Control panel
• Back-feed protection Graphical interface
- Simplify system configuration, troubleshooting
- Comprehensive information
The UPS module
Why is it the smartest?

Service friendly AC and DC capacitors


Back-feed
Bypass
protection “Plug-and-play” easy to be replaced
- 11 years lifetime for DC capacitors
Back-feed Rectifier Output
Mains
protection
DC-DC bus
Inverter
relay Load
- Lower spare parts costs
- Simplified maintenance (Lower MTTR)
Battery
relay
Battery Multi processor
Display control logic
Load: 100 kW Soft start
Charger
Voltage: 230V

The UPS gradually increases the power supplied


from the utility to the load
- Higher load protection
- Generator compatibility avoid trip of its
breakers
Every module includes
• Static bypass Superior efficiency
• Power unit 97.1% - Pay less for every kWh
• Control logic - Cost of energy and cooling system
• Control panel downsized (Reduced TCO)
• Back-feed protection
The UPS module
Models

10 / 20 / 25 kW

132 mm
3U

603 mm

442 mm

50 / 60 kW

197 mm
4.5U

800 mm
660 mm
The UPS frame
Our modular concept
Manual
bypass

Back-feed UPS module


protection
Bypass
Bypass
Back-feed Rectifier Inverter Output
fuse
protection relay
Mains DC-DC bus Load

Output
Battery isolator
relay
Battery Multi processor
Display control logic
Battery Load: 100 kW

breaker Charger
Voltage: 230V

In-frame, per module, front access

Bypass fuses (usually inside the module) DC Battery line protection


- Increases availability - Easy access to battery line isolation and
- Reduces MTTR protection

Parallel output isolator (usually not present) Fault tolerant ring parallel communication bus
- Eliminates human error on power (usually single communication line)
upgrades/downgrades - Reduces system costs
- Allows for full module test in-hot-frame - Increases safety for service personnel
The UPS frame
Our modular concept

Manual bypass
- Reduces system costs
- Increases safety for service personnel

Dual or single-input feed (Field configurable)


- Two separate power pads protects the
critical load when the load is transferred to
static bypass

Hot-swappable
- Load always protected on inverter
- Lower repair and service time

Top or bottom cable entry


- Increased Flexibility on installation
- Ease of Infrastructure project developments
The UPS frame
Models

CP050-I240-A0 CP150-E-A0 CP100-I320- CP251-E-B0


B0

10, 20, 25 kW modules


CP050-I080-A1 CP100-E-A1

CAB-UR100-E-C1

CAB-UR050-E-C0
CP025-E-V
CAB-UR025-E-C0

up to 25 kW < 25 kW < 50 kW < 100 kW < 50 kW, < 100 kW < 50 kW, < 150 kW < 100 kW < 250 kW
80 x(7/9 Ah) 240 (7/9Ah) 320 (7/9 Ah) or
80 (28Ah)
The UPS frame
Models

CAB-CP600B-E-D0
CAB-CP300B-E-B0 CAB-CP300T-E-B0 CAB-CP600T-E-D0

50, 60 kW modules

< 300 kW < 600 kW


Multi-frame
Triple-mode parallel communication

X Single communication line X Ring (dual) communication line  Triple-mode parallel bus
× Single point of failure  Communication remains if there is a  Three independent communication lines
× Single communication electronics disconnection and three electronics (one on each module)
× System fails when a cable is cut  Cable cutting resistant
× Wrong signal when there are  Redundant signal to overcome eventual
disruptions/noises in the line noises

UPS 1 UPS 2 UPS 3 UPS 1 UPS 2 UPS 3

Cable cutting
resistant
Which path would you take?
TRIPPLE – MODE parallel communication

X Single point of failure  Triple-mode parallel bus

Gerardo Lecuona www.centiel.com 24


Connectivity
CumulusPower

Included
1 Multidrop connections 1
2 Bluetooth (mobile service tool - iOS/Android)
2
3 1x RS232 (service tool - CST)
3
4 1x RS485 (graphical display or remote panel)
5 5x Dry output contacts 4

6 6x Input contacts - (Battery temp. monitoring, Remote Shutdown, AUX1 5


External manual bypass, AUX2 External output switch, Generator operation
7 Expansion slot for SNMP adaptor 6

Optional
 SNMP/Modbus adaptor
 Battery temperature sensor
 Ambient temperature sensor 7
 Humidity sensor
The complete installation
Reduced system costs

1 Reduced upfront investment (pay as you grow)


6 1
2 Eliminate ad-on external components: back-
2
feed protection, maintenance bypass, bypass
fuses, battery DC breakers, battery charger
3 3 High efficiency = less heat
5
4 High battery changing capability (faster
charging time)
5 Lower battery costs (Flexibility on the number
4 and type of batteries)
6 Avoid oversized diesel generators
Summary
CumulusPower is…

1. Swiss designed and manufactured UPS


2. Based on a 10,20,25, 50 and 60kW modules
3. With flexible frames solutions to cover any applications from
10kW up to 3.6MW
4. Maximizes Power availability & Minimizes TCO
5. Provide the differentiator and competitive advantages to
overcome the market
6. Maximizes profitability for our partners and customers
centiel.com 28