Programmable Logic

Controllers

Allen Bradley
ALLEN BRADLEY PLC

Manufacturers :-
Allen Bradley -Hardware
Reliance Electric -Hardware
Rockwell Solution(RS) -Software
Types of PLC:-

Compact:- I/O number fixed I/O


modules are fitted on CPU.

Modular :- I/O can be as per selection


of I/O modules
Allen Bradley
o PLC S/W I/O capacity
Pico Pico soft 32
Mirco Logix RS logix500 156
SLC 500 RSlogix500 4096/4096
Logix platform RSlogix5000 1,28,000

Communication s/w:-
RS linx :- It is a list of software drivers
AB PLC Hardware:-
Central Processing Unit
Input Module
Output Module
Power supply
Bus System
Rack(chassis)

Chassis types:-
4,7,10&13 slots
(17 slots in Logix Platform)
Protocol:-
RS232:-
(Recommended Standard)

One to one commn(two component)


Baud rate 19,200 bits/sec
Maximum length 10m.
Connector nine pin Delta(Pin 2,3&5)
DH485:-
(Data Highway)
32 nodes(components)
Baud rate 19,200 bits/sec
Maximum length -4000 feet(1.2km).
CPU memory Organization:-

oCPU memory divided in two parts:-


Program Files
Data Files
Program files:-
System 0 -Manufacturer program
System 1 -Reserve file
Ladder 2 -Main user file
-ladder 3 to 255 for
subroutine program
CPU memory Organization

Data files:-
o0 -Output - O -- o/p status
1 -Input - I -- i/p status
2 -Status - S2 -- CPU data
3 -Binary - B3 -- Flag(memory bit)
4 -Timer - T4 -- Timer status
5 -Counter - C5 -- Counter status
6 -Control - R6 -- Specific data

7 -Integer - N7 -- whole no. data


8 -Float - F8 -- Decimal no.data
Addressing I/O:-
FILE WORD BIT
LETTER
: SLOT
NO
. NO
/ NO

I : 1 . 0 / 0 (0 to 15)
I : 1 . 1 / 0 ,,
O : 2 . 0 / 0 ,,
O : 2 . 0 / 0 ,,
Addressing BINARY (Flag):-
FILE FILE WORD BIT
LETTER NUMBER : NUMBER / NUMBER

B3 : 0 / 0 (0 to 15)
B3 : 1 / 0 ,,
. . .
. . .
. . .
B3 : 15 / 15
Addressing of Programming
Instructions:-

TIMER :- T4:0 …………. T4:255(as per


PLC)
COUNTER :- C5:0……………………. C5:255
CONTROL :- R6:0……………………. R6:255
INTEGER :- N7:0…………………… N7:255
FLOAT :- F8:0……………………. F8:255
Addressing of Symbols:-

----||----- XIC NO
----|\|---- XIO NC
----( )---- OTE O/P COIL
----( L )---- OTL O/P COIL
----( U )---- OTU O/P COIL
Basic Rules for Ladder logic:-
•I/P address can be used in series &
parallel
• O/P address can be used in parallel
• O/P address can be used as I/P address
• I/P address not to be used as O/P
address
• I/P address can be repeated as I/P
address
• O/P address not to be used as O/P
address except Latch & Unlatch o/p coil
 Communication Protocols Comparison
 Communications protocols are broadly distinguished by speed of the communication, number of nodes
supported and length of network.

DH+ DH485 Device Control


Net Net

Baud rate 230.4 19.2 500 kbit/s 5 Mbit/s


max kbits/s kbit/s

No. of 64 32 64 99
max. nodes

Network 3.048 km 1.2 km 0.487 km 30 km


Length
Allen Bradley : PICO
Allen Bradley : Micrologix
Allen Bradley : SLC
Allen Bradley : PLC
Allen Bradley : CompactLogix
Allen Bradley : FlexLogix
Allen Bradley : ControlLogix
Allen Bradley : -
SLC system
System Components

A modular-hardware SLC / 1746 control system at minimum consists of a


processor module and I/O modules in a single 1746 chassis with a power
supply. The 1746 power supply connects to the left end of each 1746 chassis.
You can configure a system with one, two, or three local chassis, for a total
of 30 local I/O or communication modules maximum. You connect multiple
local chassis together with chassis interconnect cables to extend the
backplane signal lines from one chassis to another.

Choose the processor module with the on-board communication ports you
need. You optionally add modules to provide additional communication
ports for the processor. For I/O in locations remote from the processor, you
must add an I/O scanner module for ControlNet, DeviceNet, or Universal
Remote I/O port.

Depending on the communication ports available on your particular SLC


control system, you can select operator interfaces that are compatible with
those particular ports.
Product Design : CPU

SLC 500 processors are available in a large range of forcible I/O (4096
inputs plus 4096 outputs maximum) and maximum user memory (1K
instructions through 64K words). Several modular processors are capable
of controlling remotely located I/O. By adding an I/O scanner module,
you can use these processors to monitor/control these remotely located
I/O across ControlNet, DeviceNet, and Universal Remote I/O links.

The 1746/1747 platform provides a modular-hardware system for


maximum flexibility. SLC 500 processors are single-slot modules that
you place into the left-most slot of a 1746 I/O chassis. For 1746 I/O in a
location remote from the processor, the I/O adapter is a single-slot
module that you place into the left-most slot of a 1746 I/O chassis.

The 1746 I/O chassis are built for back-panel mounting. The 1746 I/O
chassis is available in sizes of 4, 7, 10, or 13 module slots. The 1746 I/O
modules are available in densities of a maximum of 32 I/O per module.
Product Design : CPU

SLC 500 processors are available in a large range of forcible I/O (4096
inputs plus 4096 outputs maximum) and maximum user memory (1K
instructions through 64K words). Several modular processors are capable
of controlling remotely located I/O. By adding an I/O scanner module,
you can use these processors to monitor/control these remotely located
I/O across ControlNet, DeviceNet, and Universal Remote I/O links.

The 1746/1747 platform provides a modular-hardware system for


maximum flexibility. SLC 500 processors are single-slot modules that
you place into the left-most slot of a 1746 I/O chassis. For 1746 I/O in a
location remote from the processor, the I/O adapter is a single-slot
module that you place into the left-most slot of a 1746 I/O chassis.
Product Design : Chassis and I/O modules

The 1746 I/O chassis are built for back-panel mounting. The 1746 I/O
chassis is available in sizes of 4, 7, 10, or 13 module slots. The 1746 I/O
modules are available in densities of a maximum of 32 I/O per module.

You can configure a system with one, two, or three local chassis, for a
total of 30 local I/O or communication modules maximum. You connect
multiple local chassis together with chassis interconnect cables to extend
the backplane signal lines from one chassis to another. This same 30-I/O-
module limit applies to a chassis remote from the processor with an I/O
adapter module in the first slot.
CPU Specifications
CPU Selection
Various Processor Available
Various Processor Available
Memory Devices
Analog I/P modules

1746 Analog module do not require external power


Analog O/P modules
Analog I/O combination modules
RTD modules
Thermocouple modules
Digital AC Input modules
Digital DC Input modules
Digital AC Output modules
Digital DC Output modules
Digital Contact Output modules
Digital I/O Combination modules
Distributed I/O Modules
Types of wiring
Communication Modules
Communication Modules
Communication
Various models of SLC processors have various on-board ports for
communication with other processors or computers. Also, separate
modules are available to provide additional communication ports for
communication with other processors, computers, and remotely located
I/O.

Each SLC processor has one or two built-in ports for either EtherNet/IP,
DH+, DH-485, or RS-232 (DF1, ASCII, OR DH-485 protocol)
communication.

I/O adapter modules for 1746 I/O are also available for ControlNet and
Universal Remote I/O links.
PLC Programming Software