ALLEN BRADLEY
ALLEN BRADLEY
Controllers
Allen Bradley
ALLEN BRADLEY PLC
Manufacturers :-
Allen Bradley -Hardware
Reliance Electric -Hardware
Rockwell Solution(RS) -Software
Types of PLC:-
Communication s/w:-
RS linx :- It is a list of software drivers
AB PLC Hardware:-
Central Processing Unit
Input Module
Output Module
Power supply
Bus System
Rack(chassis)
Chassis types:-
4,7,10&13 slots
(17 slots in Logix Platform)
Protocol:-
RS232:-
(Recommended Standard)
Data files:-
o0 -Output - O -- o/p status
1 -Input - I -- i/p status
2 -Status - S2 -- CPU data
3 -Binary - B3 -- Flag(memory bit)
4 -Timer - T4 -- Timer status
5 -Counter - C5 -- Counter status
6 -Control - R6 -- Specific data
I : 1 . 0 / 0 (0 to 15)
I : 1 . 1 / 0 ,,
O : 2 . 0 / 0 ,,
O : 2 . 0 / 0 ,,
Addressing BINARY (Flag):-
FILE FILE WORD BIT
LETTER NUMBER : NUMBER / NUMBER
B3 : 0 / 0 (0 to 15)
B3 : 1 / 0 ,,
. . .
. . .
. . .
B3 : 15 / 15
Addressing of Programming
Instructions:-
----||----- XIC NO
----|\|---- XIO NC
----( )---- OTE O/P COIL
----( L )---- OTL O/P COIL
----( U )---- OTU O/P COIL
Basic Rules for Ladder logic:-
•I/P address can be used in series &
parallel
• O/P address can be used in parallel
• O/P address can be used as I/P address
• I/P address not to be used as O/P
address
• I/P address can be repeated as I/P
address
• O/P address not to be used as O/P
address except Latch & Unlatch o/p coil
Communication Protocols Comparison
Communications protocols are broadly distinguished by speed of the communication, number of nodes
supported and length of network.
No. of 64 32 64 99
max. nodes
Choose the processor module with the on-board communication ports you
need. You optionally add modules to provide additional communication
ports for the processor. For I/O in locations remote from the processor, you
must add an I/O scanner module for ControlNet, DeviceNet, or Universal
Remote I/O port.
SLC 500 processors are available in a large range of forcible I/O (4096
inputs plus 4096 outputs maximum) and maximum user memory (1K
instructions through 64K words). Several modular processors are capable
of controlling remotely located I/O. By adding an I/O scanner module,
you can use these processors to monitor/control these remotely located
I/O across ControlNet, DeviceNet, and Universal Remote I/O links.
The 1746 I/O chassis are built for back-panel mounting. The 1746 I/O
chassis is available in sizes of 4, 7, 10, or 13 module slots. The 1746 I/O
modules are available in densities of a maximum of 32 I/O per module.
Product Design : CPU
SLC 500 processors are available in a large range of forcible I/O (4096
inputs plus 4096 outputs maximum) and maximum user memory (1K
instructions through 64K words). Several modular processors are capable
of controlling remotely located I/O. By adding an I/O scanner module,
you can use these processors to monitor/control these remotely located
I/O across ControlNet, DeviceNet, and Universal Remote I/O links.
The 1746 I/O chassis are built for back-panel mounting. The 1746 I/O
chassis is available in sizes of 4, 7, 10, or 13 module slots. The 1746 I/O
modules are available in densities of a maximum of 32 I/O per module.
You can configure a system with one, two, or three local chassis, for a
total of 30 local I/O or communication modules maximum. You connect
multiple local chassis together with chassis interconnect cables to extend
the backplane signal lines from one chassis to another. This same 30-I/O-
module limit applies to a chassis remote from the processor with an I/O
adapter module in the first slot.
CPU Specifications
CPU Selection
Various Processor Available
Various Processor Available
Memory Devices
Analog I/P modules
Each SLC processor has one or two built-in ports for either EtherNet/IP,
DH+, DH-485, or RS-232 (DF1, ASCII, OR DH-485 protocol)
communication.
I/O adapter modules for 1746 I/O are also available for ControlNet and
Universal Remote I/O links.
PLC Programming Software