Cooler Pump and Fan Speed Check Point

You might also like

Download as pptx, pdf, or txt
Download as pptx, pdf, or txt
You are on page 1of 4

COOLER PUMP AND

FAN SPEED CHECKING


POINT AND CONTROL
SYSTEM
Tata Steel Slide 2

Control Circuit check Points for Variable speed of Cooler Fan

OMQ Division

Cooler Fan
Fuel Tank

Fuel Temp. Sensor


ST Solenoid
SF Solenoid
Main Controller
Out put pressure 50 , 180 , 240 bar

Out put
Out Put Current From Controller
Current 285
to 309 mA
SF Solenoid Output Pressure

Cooler Pump Delivery Line

Pressure 0
Cooler Pump Drain
to 14 bar
Line

Hyd. Tank
Drain Line Filter

Pilot Line

Hyd. Oil Temp. Sensor


Hyd. Suction Line
OMQ Division Tata Steel Slide 3

 E573 :- (EX1200-5D) On this machine, Cooler Pump failure rectified, (Pump Repaired at TSL-Joda Site),
and after flushing the Suction Line, Hydraulic tank, Oil Cooler and Oil cooler line, fresh Hyd. Oil charged
(Servo make TH46) , changed Hyd. Filter, Drain line filter. And Recon Cooler Pump Fitted on the
Machine (THCM Workshop Repaired Pump). After Bleeding of all 03 Main pump and cooler pump,
machine started , and found, Cooler Pump Not Regulating.

 Checked SF Solenoid Output Pressure , found 0 bar, ( Not a Single drop of oil, pilot hose found dry)
 Checked the Wire Continuity found OK.
 Check the Current found No Current ( Req. current 285mA to 309mA w.r.t Temp. difference)
 Checked the Hydraulic Temp. sensor found OK
 Checked Fuel Temp. Sensor found OK
 Swiped the Main Controller A & B , for checking, found the desired pilot pressure with respect to current
in SF solenoid)
 Changed the Main Controller A, with New and the issue resolved.

Now, There is regulation in Hyd. Cooler pump, w.r.t to Temp. difference , and machine is working fine,
Meanwhile Dismantled the failed controller and found, there was shot circuit and circuit breakage inside
controller, which is responsible for supplying current to SF Solenoid for Regulating the Cooler Pump.
OMQ Division Tata Steel Slide 4

Thank You

You might also like