Professional Documents
Culture Documents
E300 Series Mini-Type Integrated Universal Inverter: © 2006, ZTE Corporation. All Rights Reserved
E300 Series Mini-Type Integrated Universal Inverter: © 2006, ZTE Corporation. All Rights Reserved
E300 Series Mini-Type Integrated Universal Inverter: © 2006, ZTE Corporation. All Rights Reserved
Appearance
E300-2S0002/E300-2S0004
E300-2S0007/E300-2S0015 E300-4T0007/E300-4T0015
Model
E300 -4T-0007B
Derivative
Series E300
Mini-type Integrated Universal Inverter
model
220V
380V
E300 Introduction
Convenient maintenance and installation fan External keypad control 8p telephone line
External Communication
E300B series built-in standard RS485 communication interface and adopts MODBUS protocol.
PC control
PLC control
PC control interface
Wonderful appearance with compact size and wall mounting or side-by-side installation.
Side-by-side installation
Flexible fan cover design achieves independent installation and disassembly easily.
35
15
20
25
30
35
50HZ 45HZ 40HZ 35HZ 30HZ 25HZ 20HZ 15HZ 10HZ 5HZ
000
001
010
011
100
101
110
111
000
Adopt isolated independent duct for protecting boards avoiding dust and better cooling effect
Embed capacitance for design of much closer between exothermic electron organ and radiating system
Acc time
T Jog signal
8
A
Reliable Multi-protectionover-current, overload, over-volt, short circuit etc. up to 20 protection functions to ensure max effective protection for inverter and motor
Overcurrent
t A
Overcurrent prohibition
t
Overvolt
t
Over-volt prohibition
t
Short circuit
Overload
Short circuit
Short circuit overload feedback protects driving equip and inverter effectively.
Short circuit
When short circuit overload, inverter warns and pauses load power supply.
2006, ZTE Corporation. All rights reserved.
10
Prohibiting REV function ensures not to switch to REV running even any signal as fans or pumps which may cause REV problem.
Parameter set: REV avoidance is valid
REV incipient faultREV may cause fans/ pumps impeller loose that may lead to unparallel impeller running, even mechanical accident.
Control Panel
Return Up
Replacement
Set
Down
Application Case
-for engraving machine
PC control
Power supply
RS485 converter
Engraving machine
2006, ZTE Corporation. All rights reserved.
Basic Wiring
3-Ph b re a ke r
y 3-Ph p o w e r sup p l
M o to r
R S T X1
U V W E Ta Tb Tc PP
Fa iure w a r i g o u tp u t l nn
M
Earth
Pro g ra m m a b l e i p u t te rm i a l n n
X2 X3 CM E
PB
Exte rna lb ra ki g re si r n sto
FWD
FW D
24V
A u xii ry D C p o w e r sup p l la y
CM
AO
V o l e te r0~10V tm
CM
10V AI CM
OC
O p e n c i u i c o le c to r o u tp u t rc t l
CM
Dimension
E300-2S0002/E300-2S0004
W W1
W1
H1
Screw spec
H1 H
67.5
81.5
132.5
148
134.5
M4
E300-2S0007/E300-2S0015 E300-4T0007/E300-4T0015
W W1
W1
H1 H
W 101.5
H1 147.5
H 165
D 154.5
Screw spec M4
86.5
Analogue Freq 0.4% of max output freq terminal input setting Resolution Digital set 0.1 Hz Analogue input Within 0.4% of maximum output freq Freq Precision Digital input Within 0.1% of setting output freq Torque boost Manual set: 0.0~20.0% of rated output V/F control Auto current / volt limit It will check motor stator current and volt automatically based on special arithmetic to control within allowable range to ensure minimum failure during acc/ dec or stable running.
Ty p i c a l F u n c t i o n s
Seven programmable multi-speed control, three multi-speed control terminal RS485 communication Standard built-in RS485 interface, RS485 communication protocol E300B and MODBUS for choice Analogue input Panel potentiometer setting, DC volt 010VDC current 020mA Freq Operation panel settingRS485 interface setting, UP / DW terminal setting Digital input control Relay and OC One OC output and one relay output (TA, TB, TC) as many as 9 Output output types of choice signal Analogue One 0~10V volt signal output Acc /dec time setting 0.1600s continuous setting, S curve and linear mode for choice Multi-speed control DC braking Low noise running Running function Action freq 0~500.0 Hz, action time 0~20.0 S Carrier wave freq 1.5 KHz ~ 12.0 KHz continuous adjustments to ensure the lowest motor noise. Upper and Lower freq setting, reversal operating restriction, RS485 communication, freq increasing/decreasing control etc.
Output freq, current and voltmotor rotate speedfreq setting, Operation Running state module temperature, analog I/O Display panel Last four times failure record, output freq, current, volt and DC volt of display Warning last fault trip for running parameter record Protection / warning function Over current, over volt, under volt, overheating, short circuit etc.
Application
E300 series not only applies in kinds of light industry as textile, transmission etc., but also applies in various high speed applications, such as mill, engraving machine, centrifuge etc. with output frequency reaching 1000 Hz.
E300
The End