Download as ppt, pdf, or txt
Download as ppt, pdf, or txt
You are on page 1of 17

RPI SYSTEM

INTRODUCTION
The current concept of increasing the retention & stability of RPD by changing the fulcrum location is known as RPI system. Here R stands for mesioocclusal rest, P stands for proximal plate, & T stands for I bar of clasp assembly.

OBJECTIVE Distal extension of RPD acts as a long effort arm across the distal rest fulcrum to cause the clasp tip resistance arm to engage the tooth undercut. This results in a harmful tipping or torquing of tooth & is greater with stiff clasp & more denture base area causing poor retention & stability of RPD. To improve these problems changing the fulcrum location & increasing the resistance arm engaging effect can be brought by RPI system.

INDICATION 1) In kennedy class 1 cases where denture retention depends on tissue borne saddle. 2) In kennedy class II cases where both tooth & tissue borne retention is needed. 3) In kennedy class II, modification cases. 4) In case of long effort arm where fulcrum line is needed to be changed & resistance arm is to be increased.

CONTRA-INDICATION When the abutment tooth is inclined lingually or buccaly. In severe undercut areas. Where sulcus depth is insufficient. In those cases where distal abutments teeth are distally tilted.

Disadvantage Gingivally approaching I bar causing food impaction & resulting in periodontal problem.

The components of this clasp assembly are: "R" - rest (always mesial) "P" - proximal plate "I" - I-bar (retentive arm)

The rest is located on the mesio-occlusal surface of a premolar or mesiolingual surface of a canine. The minor connector is located in the mesio-lingual embrasure but is not in contact with the adjacent tooth (prevents wedging).

The proximal plate (essentially a wide minor connector) is located on a guide plane on the distal surface of the tooth. The superior edge of the proximal plate is located at the bottom of the guide plane (at approximately the junction of the occlusal and middle third of the guide plane). The proximal plate extends lingually so that the distance between the minor connector and the proximal plate is less than the mesio-distal width of the tooth. The plate is approximately l mm. thick and joins the framework at a right angle.

The I-bar clasp is located on the buccal surface of the premolar and on the mesio-buccal surface of the canine. The I-bar originates at the gridwork and approaches the tooth from the gingival direction. The bend in the I-bar should be located at least 3 mm. from the gingival margin. This distance will prevent food entrapment and provide the length for the necessary flexibility in the clasp arm. The clasp is usually cast and is placed just below the height of contour line.

On premolars, the proximal plate should extend lingually so that the distance between the proximal plate and the mesio-occlusal rest is less than the mesio-distal width of the tooth. The proximal plate in conjunction with the mesial rest (and minor connector) acts as the reciprocating element of the clasp and prevents the lingual migration of the tooth when the clasp arm moves over the height of contour.

On cuspids, the minor connector cannot be used for reciprocation since it does not contact the tooth until after the retentive element has passed across the height of contour and the partial denture is seated. This is because the mesio-lingual rest is located fairly low on the cingulum of the tooth. Therefore, the I-bar is located in the mesio-buccal undercut and is reciprocated directly by the proximal plate.

The guiding plane is a parallel surface prepared on the occlusal one third of the distal surface of the tooth. The guiding plane extends lingually enough so that, along with the mesial rest, it can prevent lingual migration of the tooth. It is approximately 2 to 3 mm in height.

You might also like