Download as ppt, pdf, or txt
Download as ppt, pdf, or txt
You are on page 1of 13

CSI 9420 Wireless Machinery Health Transmitter

Wireless HART Connectivity

CSI 9420 Wireless Machinery Health Transmitter


While sensor should be mounted on the machine being monitored, the transmitter should be mounted off the machine. Transmitter contains: signal processing, battery, radio communication

Overall Velocity, PeakVue and Temperature scalar values Transmitter can connect to one accelerometer, one accelerometer with embedded temperature, or two accelerometers

Company Confidential

CSI 9420 Wireless Application


Place on any equipment
Mount transmitter away from machine

Application
Works on any equipment Not application specific
Typical: 10 ft / 3 m

300 feet / 100 meters

CSI 9420
Wireless Vibration Transmitter Measurement processing Radio communication Power Module

1420
Smart Wireless Gateway

Outputs (scalar values) 1. Overall Vibration Units: Range: Comment: Velocity (in/sec or mm/sec) 2 Hz 1000 Hz (per ISO 10816 standard). Identifies problems like imbalance and looseness

2.

PeakVue Vibration Units: Range: Comment:


Temperature Range: Comment:

Gs Peak 1,000 Hz 20,000 Hz Quantify early bearing & gearbox defects


-30 to +250 F / -34 to +120 C When sensor with embedded temperature used Company Confidential

3.

Vibration Measurements More Than a Single Overall Value

Overall Vibration measured in Velocity units (in/sec)


2Hz-1000Hz per ISO 10816 standard. Guidelines and tables in velocity units exist to guide plant engineers and maintenance staffs on alert limits

PeakViewTM Overall measured in gs pk


PeakView is a numerical method to detect peak vibration typically due to rolling element bearing failures 1kHz to 20kHz
Company Confidential

PeakVue Provides Superior Bearing Defect Detection

PeakVue provides the earliest indication of a bearing defect Increase in PeakVue value is proportional to bearing defect severity In the late stage bearing failure a decrease in PeakVue with a corresponding increase Overall vibration indicates late stage bearing failure.

Company Confidential

Vibration Measurement More Than a Single Overall Value

Overall Velocity and PeakVue per sensor

Also can get temperature value when used with an accelerometer with an embedded temperature sensor CSI 9420 is user configurable.
Update rate is user configurable Three user settable alarm levels per process variable Update rate of once per 30 minutes is recommended to obtain at a 2-3 year battery life

900 MHz NA Commercial availability expected in the Q2 FY2008 time frame 2.4 GHz Wireless HART availability expected Q3 FY2008
Company Confidential

EDDL Enabled Trend of Sensor 1 Velocity Value in AMS Device Manager

Company Confidential

EDDL Enabled Gauges Show All Process Variables in a Single View

Company Confidential

Fan Monitoring Application

Bearing defect detected with PeakVue

Sensor mounted on the bearing.

Company Confidential

Closer View of Early Stage Bearing Fault Identified with PeakVueTM

Bearing defect shows evidence of early-stage Impacting.

Company Confidential

Get Started With a CSI 9420 SmartPack

5 CSI 9420 Transmitters

1 1420 Gateway INSTALL service SmartStart service AMS Device Manager 5 Tag HART Modem

1420 Gateway

INSTALL

SmartStart CSI 9420 Machinery Health Transmitters

Company Confidential

CSI 9420 Advantages

Delivers overall velocity AND PeakVue per sensor

Overall measurement good down to 2Hz Two channel inputs Update rate configurable for 1 minute updates Delivers data through same network as process values temperature, pressure, flow, level Can communicate data to multiple hosts simultaneously Wireless HART standard exists and will be part of ISA100 standard.

Company Confidential

Company Confidential

You might also like